11 |
P a g e
For the practitioner
A good practitioner will help coach you and your child in helping them become dry.
MO4 Model
The MO4 model is a reliable model but they won’t last for more than 6 months even if well cared
for.
The most common malfunctions and causes are
:
-
Corrosion of the electronics inside by dropping the alarm in the toilet or immerge it otherwise.
-
Breaking of the plastic clip of the telephone connector because it has been removed frequently.
Leave the plug of the sensor wire connected to the alarm.
-
Breaking of the level to close the gripper, because the lever is moved in the wrong direction
when closing the gripper.
-
Breaking of the small plastic clip to keep the battery cover closed because of forceful opening of
the battery cover.
-
The easy clip itself rarely breaks unless used for a long time.
-
The buzzer and vibrator rarely malfunction, unless the alarm unit is immersed in water.
MO24 Model
-
This body worn alarm is similar as the MO4 in functionality.
-
Has the option to record a message.
-
Has 2 AA batteries.
-
Is slightly larger than the MO4.
Servicing
Practitioners will need to sanitize and clean alarm and easy clip sensor between each client that is
seen. The alarm will last between 2 to 3 clients and may last longer if it is regularly cleaned and
maintained and the levers and covers operated gently and the alarm is not immersed in the toilet
or other fluid. There is wear and tear over time so it is important to inspect for any malfunction,
and test the electrical operations. Once malfunctioning, Malem will not repair the unit and has to
be replaced.
Sensor Cleaning and Sanitizing
Many organisations will require protocols for cleaning and products to help with the cleaning:
1.
Select cleaner such as Dettol of Flash liquid and mix as per instructions in warm or cold water.
2.
Submerge sensor while disconnected from the alarm (ensure alarm terminals are not
submerged) in the detergent.
3.
Using a soft tooth brush, scrub each gripper removing all traces of lint, especially at the end of
the gripper.
4.
Remove from solution and rinse well with water
5.
Hang over clothes rack to air dry, wire side up, indoors. Prolonged exposure to intense
detergents or heat could damage the plastic or copper griper.
6.
When completely dry, store the Easy-Clip sensor system and Alarm securely.