Fig. 3.3.
The standard bi-static fixed offset 16 channel array, with 9 transmitter and 8 receiver
antennas. Each receiver is synchronized against two transmitters in order to make the physical
channel spacing as small as possible.
3.2 ProEx control unit and MIRA option
The ProEx control unit is mounted to the MIRA option, with the two 25-DSUB connectors, and secured
by two screws on each side. See Fig. 3.4.
Fig. 3.4.
Connection of the ProEx unit to the MIRA option.
IMPORTANT NOTE!
The interface between the main ProEx unit and the array option is not protected
against over voltage. Therefore the units must be powered off before connection/de-connection.
Connect the Ethernet cable from the ProEx unit and further on to the main connector (Fig.3.1) and the
power cable from the power box to the ProEx unit. Note! The power box is equipped with fuses for
each source.