Replacing carbon brushes 

1

 

 

001145 

Remove and check the carbon brushes regularly. 
Replace when they wear down to the limit mark. Keep 
the carbon brushes clean and free to slip in the holders. 
Both carbon brushes should be replaced at the same 
time. Use only identical carbon brushes. 

1

2

 

 

015051 

Use a screwdriver to remove the brush holder caps. 
Take out the worn carbon brushes, insert the new ones 
and secure the brush holder caps. 
To maintain product SAFETY and RELIABILITY, repairs, 
any other maintenance or adjustment should be 
performed by Makita Authorized Service Centers, 
always using Makita replacement parts. 

1. Brush holder 

cap 

2. Screwdriver 

1. Limit mark 

Содержание MT904

Страница 1: ...1 ENGLISH Original instructions INSTRUCTION MANUAL DOUBLE INSULATION IMPORTANT Read Before Using Angle Grinder MT904 MT905 015065...

Страница 2: ...r public low voltage distribution systems of between 220 V and 250 V Switching operations of electric apparatus cause voltage fluctuations The operation of this device under unfavorable mains conditio...

Страница 3: ...of dust extraction and collection facilities ensure these are connected and properly used Use of dust collection can reduce dust related hazards Power tool use and care 18 Do not force the power tool...

Страница 4: ...ate area of operation 10 Hold the power tool by insulated gripping surfaces only when performing an operation where the cutting accessory may contact hidden wiring or its own cord Cutting accessory co...

Страница 5: ...rger power tool is not suitable for the higher speed of a smaller tool and may burst Additional Safety Warnings 17 When using depressed centre grinding wheels be sure to use only fiberglass reinforced...

Страница 6: ...ration pull the switch trigger and then push in the lock button To stop the tool from the locked position pull the switch trigger fully and then release it ASSEMBLY CAUTION Always be sure that the too...

Страница 7: ...ontrol leading to personal injury CAUTION Never switch on the tool when it is in contact with the workpiece it may cause an injury to operator Always wear safety goggles or a face shield during operat...

Страница 8: ...d at the same time Use only identical carbon brushes 1 2 015051 Use a screwdriver to remove the brush holder caps Take out the worn carbon brushes insert the new ones and secure the brush holder caps...

Страница 9: ...9...

Страница 10: ...10...

Страница 11: ...11...

Страница 12: ...12 Makita Corporation www makita com 885369 1...

Отзывы: