background image

STATIC ELECTRICITY 

Plastic dust lines generate high amounts of static electricity as dust 
chips pass through them. Although rare, sparks caused by static 
electricity can cause explosions or fire. To reduce this risk, make 
sure all dust lines are thoroughly grounded by Using a grounding 
wire. 

REGULAR CLEANING   

 

Regularly check/empty the collection bags or drum to avoid the 
buildup of fine dust that can increase the risk of fire. Make sure to 
regularly clean the surrounding area where the machine is 
operated—excessive dust buildup on overhead lights, heaters, 
electrical panels, or other heat sources will increase the risk of fire.

No list of safety guidelines can be complete. Every shop environment is different. 
Accidents are frequently caused by lack of familiarity or failure to pay attention. Use 
this machine with respect and caution to lessen the possibility of operator injury. If 

normal safety precautions are overlooked or ignored, serious personal injury may occur. 

FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY. 
FOR YOUR OWN SAFETY, READ AND UNDERSTAND THE INSTRUCTION MANUAL 
BEFORE OPERATING THE MACHINE.   

KEEP WORK AREA CLEAN. Cluttered areas and benches invite accidents. 
DON’T USE IN DANGEROUS ENVIRONMENT. Don’t use this unit in damp or wet 
locations, or expose it to rain. Keep work area well-lighted. 
KEEP CHILDREN AND VISITORS AWAY. All children and visitors should be kept a 
safe distance from work area. 
DISCONNECT UNIT before servicing. 
CHECK DAMAGED PARTS. Before further use of the unit, properly repair or replace 
any part that is damaged. 

2. Technical Specification

The following information represents the detailed data and dimension for reference. 

2.1 Specification 

MODEL NO. 

FM300CA

FM350CA 

Motor Power 

1500W 

2200W 

Fan diameter 

305mm 

356mm 

Inlet diameter 

125mm 

1

50

mm 

Number of intake holes 

2x100mm 

3

x100mm 

 

h

m

 

0

5

3

1

 

h

m

 

0

5

1

1

 

w

o

l

F

 r

i

A
Cartridge Filter size 

Φ340mm×600mm 

Φ340mm×800mm 

2

Greetings,

Congratulations, you just purchased the BMS.3200.IR Precision Saw, which was developed with the 
Maksiwa’s highest standards of technology and quality. Your BMS.3200.IR Precision Saw allows you 
to have the highest productivity in woodworking. Besides a great finish, the BMS.3200.IR ensures that 
your cuts are always precise. It should be noted that to use this machine with maximum efficiency,
you should read and understand the instructions in this manual.
Visit our website to know about our launches and other product lines:

www.maksiwa.com

Содержание FM350CA

Страница 1: ...300CA 1800H FM350CA 1900H CAREFULLY READ THE INSTRUCTION MANUAL BEFORE USE THE MACHINE KEEP THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE CYCLONE 3HP DUST COLLECTOR INSTRUCTION MANUAL FM350CA Attention...

Страница 2: ...16 5 3 Removing Replacing collection drum bag 16 5 4 Removing Replacing filter bag 17 5 5 Removing Replacing canister filter 17 6 Troubleshooting 18 7 Diagram and part list 20 7 1 Diagram for FM350CA...

Страница 3: ...a substitute for proper accident prevention measures WARNING Some dust created by power sanding sawing grinding drilling and other construction activities may contain chemicals including lead birth d...

Страница 4: ...ss Clean your personal protective equipment after each use and once a week 1 2Safety instructions for dust collector Long term respiratory damage can occur from using dust collectors without proper us...

Страница 5: ...open flames or other ignition sources FIRE SUPPRESSION Only operate the dust collector in locations that contain a fire suppression system or have a fire extinguisher nearby IMPELLER HAZARDS Do not pl...

Страница 6: ...P WORK AREA CLEAN Cluttered areas and benches invite accidents DON T USE IN DANGEROUS ENVIRONMENT Don t use this unit in damp or wet locations or expose it to rain Keep work area well lighted KEEP CHI...

Страница 7: ...2 Dimensions FM350CA 1900H 2 Greetings Congratulations you just purchased the BMS 3200 IR Precision Saw which was developed with the Maksiwa s highest standards of technology and quality Your BMS 320...

Страница 8: ...d connected to the equipment grounding terminal or lead on the appliance Inspect the machine completely and carefully making sure that all materials such as shipping documents instructions and accesso...

Страница 9: ...e factory A Motor B ON OFF switch C Impeller housing D Inlet adapter E Intake barrel F Cyclone funnel G Dust collection drum H Canister filter I Dust collection bag J Casters 2 Greetings Congratulatio...

Страница 10: ...ides of the base 1 4 Fix the connecting rod to the bracket by long bolts flat washers and nuts 2 Greetings Congratulations you just purchased the BMS 3200 IR Precision Saw which was developed with the...

Страница 11: ...then lock the drum cover onto the cyclone funnel by the quick locking handle 2 Greetings Congratulations you just purchased the BMS 3200 IR Precision Saw which was developed with the Maksiwa s highest...

Страница 12: ...filter by bag clamp 2 Greetings Congratulations you just purchased the BMS 3200 IR Precision Saw which was developed with the Maksiwa s highest standards of technology and quality Your BMS 3200 IR Pre...

Страница 13: ...rrel and impeller housing assembly on the bracket by hexagon socket flat head screws and flat washers 5 2 Connect the intake barrel and cyclone funnel together by the steel hoop 5 3 Connect the canist...

Страница 14: ...d with the Maksiwa s highest standards of technology and quality Your BMS 3200 IR Precision Saw allows you to have the highest productivity in woodworking Besides a great finish the BMS 3200 IR ensure...

Страница 15: ...et adapter port Otherwise the lack of airflow resistance will cause the motor to operate at full amperage load which could trip your circuit breaker or blow a fuse 4 Connect machine to power 5 Standin...

Страница 16: ...d chips and large dust particles and then drops them into the collection drum The remaining fine dust travels past the impeller and is then caught by a canister filter and deposited in the plastic col...

Страница 17: ...than a table saw Knowing this required CFM is important to gauging which size of duct to use Refer to the figure below for a close estimation of the airflow each machine requires Keep in mind that mac...

Страница 18: ...contain wood dust and minimize risk of exposure firmly tie bag closed 5 3 Removing Replacing collection drum bag Dispose of the collection drum bag when dust fills it 3 4 full Replace the bag if it d...

Страница 19: ...bow 3 Install the rubber gasket and new canister filter to the elbow by the screws Dust exposure created while using machinery may cause cancer birth defects or long term respiratory damage Always wea...

Страница 20: ...Motor bearings at fault 1 Allow motor to cool reset overload if necessary 2 Clear blockages seal leaks use smooth wall duct eliminate bends close other branches 3 Clean canister filter replace canist...

Страница 21: ...Install correctly sized ducts and fittings 9 Use dust collection hood on stand 10 Install larger dust collector Dust collector blows sawdust into the air 1 Duct clamps or filter bag s are not properl...

Страница 22: ...d quality Your BMS 3200 IR Precision Saw allows you to have the highest productivity in woodworking Besides a great finish the BMS 3200 IR ensures that your cuts are always precise It should be noted...

Страница 23: ...t s a C 3 1 1 t e k c a r B 5 4 1 r o t o M 4 1 15 Screw M4x60 4 46 Dust collection drum 1 1 e l d n a H 7 4 1 t e k s a g r e b b u R 6 1 2 0 2 x 8 M w e r c s t e k c o s n o g a x e H 8 4 1 w o b...

Страница 24: ...as developed with the Maksiwa s highest standards of technology and quality Your BMS 3200 IR Precision Saw allows you to have the highest productivity in woodworking Besides a great finish the BMS 320...

Страница 25: ...ZIP Code 33073 Telephone 1 754 205 6717 Call us free 1 844 319 6594 E mail orders maksiwa com www maksiwa com 2 Greetings Congratulations you just purchased the BMS 3200 IR Precision Saw which was dev...

Отзывы: