(1)GREASE APPLICATION
R
epair
Apply Makita grease on the following rotating/sliding surfaces before assembling.
Up/Down shaking fulcrum of Blade case, Arm, Rod 16-100
Arm rotation part: Arm, Sub arm,
L/R rotating support and sliding parts of Turn base: Turn base,
Boss in the center of base, Slide plate,
Rotating and Open/Close parts of Safety cover: Center plate,Spiral spring 26,Tip of Link plate
(2)ASSEMBLY/DISASSEMBLY OF BLADE CASE( Motor part in the body)
[Disassembly]
Remove Blade , Safety cover, and Dust nozzle before disassembling.
1) Bring the cutting unit (motor section) to the blocking point (top position), and then push Stopper pin in.
2) Remove Hex. socket head bolt M6 fixing Link plate , and loosen Hex. Nut M6x10 fixing Rod 16-100.
3) Gripping Blade case (Motor sectiont in the body) with hand, pull Stopper pin and raise the body slowly. Where Torsion
spring 28 does not work, pull Rod 16-100 and take off Blade case from Arm.
[Assembly]
Reverse procedure of disassembly.
Blade Case
Stopper pin
Hex socket hed bolt M6
Rod 16-100
Part of Arm
Torsoin spring
Hex Nut M6 x 10