![Makita HS7601 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/makita/hs7601/hs7601_technical-information_4241506011.webp)
Noise suppressor
Opening of
Closed-end
connector
Strain relief
Switch
Do not put the Closed end connector
under Switch, if it is used instead of
Terminal block.
Do not put any Lead
wires on these Ribs.
Do not put any Lead
wires under Terminal
block.
Terminal
block
Setting of Noise suppressor (if used)
Face wire connected side to the bottom of
handle section and assemble Noise suppressor
to Handle.
Lead wires may interfere with assembling
of Handle cover. Therefore, put Noise
suppressor as drawn to the upper left.
Put closed-end connector to Handle section so that
the opening of Closed-end connector faces toward
Strain relief side, and then placce the Closed-end
connector here if it is used instead of Terminal block.
Setting of Closed-end connector (if used)
Fig. D-3
P 11/ 11
W
iring diagram