manualshive.com logo in svg
background image

16 ENGLISH

Switch action

WARNING:

 

Before installing the battery car-

tridge into the tool, always check to see that the 

switch trigger actuates properly and returns to 

the "OFF" position when released.

► 

Fig.3:

    

1.

 Switch trigger

To start the tool, simply pull the switch trigger. Tool 

speed is increased by increasing pressure on the switch 

trigger. Release the switch trigger to stop.

Speed change

The revolutions and blows per minute can be adjusted 

by turning the adjusting dial. The dial is marked 1 (low

-

est speed) to 5 (full speed).

► 

Fig.4:

    

1.

 Adjusting dial

Refer to the table below for the relationship between the number 

on the adjusting dial and the revolutions and blows per minute.

Number

Revolutions per 

minute

Blows per minute

5

980

5,000

4

870

4,440

3

630

3,210

2

380

1,940

1

300

1,530

CAUTION:

 

Do not turn the adjusting dial when 

the tool is running. Failure to do so may result in 

the loss of control of the tool and cause an injury.

NOTICE:

 

If the tool is operated continuously at 

low speed for a long time, the motor will get over-

loaded, resulting in tool malfunction.

NOTICE:

 

The speed adjusting dial can be turned 

only as far as 5 and back to 1. Do not force it past 

5 or 1, or the speed adjusting function may no 

longer work.

NOTE:

 

Soft no-load rotation function (For 

HR001G/HR002G)

When the speed adjusting dial is set to "4" or higher, 

the tool automatically reduces the speed at no-load to 

reduce the vibration under no-load. Once operation 

starts with a bit against concrete, blows per minute 

increase and reach the numbers as shown in the 

table. When temperature is low and there is less 

fluidity in grease, the tool may not have this function 

even with the motor rotating.

Lighting up the front lamp

► 

Fig.5:

    

1.

 Lamp

CAUTION:

 

Do not look in the light or see the 

source of light directly.

Pull the switch trigger to light up the lamp. The lamp 

keeps on lighting while the switch trigger is being pulled. 

The lamp goes out approximately 10 seconds after 

releasing the switch trigger.

CAUTION:

 

For HR001G/HR002G

If the lamp goes off after blinking for a few sec

-

onds, the active feedback sensing technology 

is not working properly. Ask your local Makita 

Service Center for repair.

NOTE:

 Use a dry cloth to wipe the dirt off the lens of 

the lamp. Be careful not to scratch the lens of lamp, or 

it may lower the illumination.

NOTE:

 If the dust collection system is installed on the 

tool, the lamp of the dust collection system lights up 

instead of the lamp of the tool.

Reversing switch action

► 

Fig.6:

    

1.

 Reversing switch lever

CAUTION:

 

Always check the direction of 

rotation before operation.

CAUTION:

 

Use the reversing switch only after 

the tool comes to a complete stop.

 Changing the 

direction of rotation before the tool stops may dam-

age the tool.

CAUTION:

 

When not operating the tool, 

always set the reversing switch lever to the neu-

tral position.

This tool has a reversing switch to change the direction 

of rotation. Depress the reversing switch lever from the 

A side for clockwise rotation or from the B side for coun-

terclockwise rotation.

When the reversing switch lever is in the neutral posi-

tion, the switch trigger cannot be pulled.

Changing the quick change chuck 

for SDS-plus

For HR002G/HR004G

The quick change chuck for SDS-plus can be easily 

exchanged for the quick change drill chuck.

Removing the quick change chuck 

for SDS-plus

CAUTION:

 Before removing the quick change 

chuck for SDS-plus, be sure to remove the bit.

Grasp the change cover of the quick change chuck 

for SDS-plus and turn in the direction of the arrow 

until the change cover line moves from the   symbol 

to the   symbol. Pull forcefully in the direction of the 

arrow.

► 

Fig.7:

    

1.

 Quick change chuck for SDS-plus 

2.

 Change cover 

3.

 Change cover line

Содержание HR004GD201

Страница 1: ...jonshammer BRUKSANVISNING 40 FI Akkukäyttöinen yhdistelmäpora KÄYTTÖOHJE 54 DA Akku kombinationshammer BRUGSANVISNING 68 LV Bezvadu kombinētais veseris LIETOŠANAS INSTRUKCIJA 83 LT Belaidis kombinacinis gręžtuvas NAUDOJIMO INSTRUKCIJA 98 ET Juhtmeta kombinatsioonihaamer KASUTUSJUHEND 113 RU Аккумуляторный трехрежимный перфоратор РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ 128 ...

Страница 2: ...1 2 3 Fig 1 1 2 Fig 2 1 Fig 3 1 Fig 4 1 Fig 5 1 A B Fig 6 1 2 3 Fig 7 1 2 3 4 Fig 8 2 ...

Страница 3: ...1 2 Fig 9 1 Fig 10 1 Fig 11 1 Fig 12 Fig 13 1 2 3 Fig 14 1 2 Fig 15 3 ...

Страница 4: ...1 Fig 16 1 A Fig 17 1 Fig 18 1 Fig 19 1 2 Fig 20 1 Fig 21 1 2 Fig 22 1 Fig 23 4 ...

Страница 5: ...3 4 1 2 Fig 24 Fig 25 1 Fig 26 1 Fig 27 2 1 Fig 28 1 Fig 29 1 2 Fig 30 5 ...

Страница 6: ...Fig 31 Fig 32 Fig 33 Fig 34 1 2 Fig 35 1 2 Fig 36 2 1 Fig 37 1 Fig 38 6 ...

Страница 7: ...1 Fig 39 Fig 40 Fig 41 Fig 42 Fig 43 1 Fig 44 3 1 4 2 Fig 45 7 ...

Страница 8: ...1 2 3 Fig 46 1 Fig 47 1 2 1 2 Fig 48 Fig 49 1 Fig 50 8 ...

Страница 9: ...1 2 Fig 51 1 Fig 52 1 Fig 53 1 2 1 2 Fig 54 1 Fig 55 2 1 Fig 56 9 ...

Страница 10: ...1 2 Fig 57 1 2 Fig 58 10 ...

Страница 11: ...idge and charger Battery cartridge BL4025 BL4040 Charger DC40RA Some of the battery cartridges and chargers listed above may not be available depending on your region of residence WARNING Only use the battery cartridges and chargers listed above Use of any other battery cartridges and chargers may cause injury and or fire Intended use The tool is intended for hammer drilling and drilling in brick ...

Страница 12: ...N60745 2 6 Hammer drilling into concrete with DX14 ah HD 6 0 m s 2 1 5 m s 2 EN60745 2 6 Chiselling func tion with side grip ah Cheq 7 5 m s 2 1 5 m s 2 EN60745 2 6 Drilling into metal ah D 2 5 m s 2 1 5 m s 2 EN60745 2 1 Model HR003G Work mode Vibration emission Uncertainty K Applicable standard Hammer drill ing into con crete ah HD 7 0 m s 2 1 5 m s 2 EN60745 2 6 Hammer drilling into concrete wi...

Страница 13: ... to prevent dust inhala tion and skin contact Follow material supplier safety data 15 Always be sure that the tool is switched off and the battery cartridge and the bit are removed before handing the tool to other person 16 Before operation make sure that there is no buried object such as electric pipe water pipe or gas pipe in the working area Otherwise the drill bit chisel may touch them resulti...

Страница 14: ...remove it from the tool or the charger 5 Charge the battery cartridge if you do not use it for a long period more than six months Important safety instructions for wireless unit 1 Do not disassemble or tamper with the wire less unit 2 Keep the wireless unit away from young chil dren If accidentally swallowed seek medical attention immediately 3 Use the wireless unit only with Makita tools 4 Do not...

Страница 15: ...tton it is not locked completely CAUTION Always install the battery cartridge fully until the red indicator cannot be seen If not it may accidentally fall out of the tool causing injury to you or someone around you CAUTION Do not install the battery cartridge forcibly If the cartridge does not slide in easily it is not being inserted correctly Indicating the remaining battery capacity Press the ch...

Страница 16: ... see the source of light directly Pull the switch trigger to light up the lamp The lamp keeps on lighting while the switch trigger is being pulled The lamp goes out approximately 10 seconds after releasing the switch trigger CAUTION For HR001G HR002G If the lamp goes off after blinking for a few sec onds the active feedback sensing technology is not working properly Ask your local Makita Service C...

Страница 17: ... and screws Before use always check for damages cracks or defor mations and make sure that the screws are tightened CAUTION Make sure that the hook is securely installed with the screws CAUTION Do not remove the battery car tridge while hanging the tool The tool may fall if the screws are not tightened CAUTION Always use a locking carabiner multi action and screw gate type and be sure to attach th...

Страница 18: ...rill bit into the tool Turn the drill bit and push it in until it engages After installing the drill bit always make sure that the drill bit is securely held in place by trying to pull it out Fig 21 1 Drill bit To remove the drill bit pull the chuck cover down all the way and pull the drill bit out Fig 22 1 Drill bit 2 Chuck cover Chisel angle when chipping scaling or demolishing The chisel can be...

Страница 19: ...d In this case warm up the battery cartridge by using the tool with no load for a while to fully obtain the tool s capability Fig 33 Hammer drilling operation CAUTION There is tremendous and sudden twisting force exerted on the tool drill bit at the time of hole break through when the hole becomes clogged with chips and particles or when striking reinforcing rods embedded in the concrete Always us...

Страница 20: ...rol of the tool By beating the dust on the filter inside the dust case you can keep the vacuum efficiency and also reduce the number of times to dispose of the dust Turn the dial on the dust case three times after col lecting every 50 000 mm 3 of dust or when you feel the vacuum performance declined NOTE 50 000 mm3 of dust equivalents to drilling 10 holes of ø10 mm and 65 mm depth 14 holes of ø3 8...

Страница 21: ...event the tool is dropped it must be tagged and removed from service and should be inspected by a Makita Factory or Authorized Service Center WIRELESS ACTIVATION FUNCTION Optional accessory for HR001G HR002G What you can do with the wireless activation function The wireless activation function enables clean and com fortable operation By connecting a supported vacuum cleaner to the tool you can run...

Страница 22: ...e less activation button briefly and hold it down again NOTE When performing two or more tool registra tions for one vacuum cleaner finish the tool registra tion one by one Starting the wireless activation function NOTE Finish the tool registration for the vacuum cleaner prior to the wireless activation NOTE Refer to the instruction manual of the vacuum cleaner too After registering a tool to the ...

Страница 23: ...vation lamp will start blinking in blue Others Red 3 seconds The power is supplied to the wireless unit and the wireless activa tion function is starting up Off The wireless activation of the vacuum cleaner is stopped Cancelling tool registration for the vacuum cleaner Perform the following procedure when cancelling the tool registration for the vacuum cleaner 1 Install the batteries to the vacuum...

Страница 24: ...ower button on the vacuum cleaner is turned on Push the wireless activation button briefly and perform the tool registration cancellation procedures again The tool registration procedures for the tool or vacuum cleaner have not finished Perform the tool registration procedures for both the tool and the vacuum cleaner at the same timing Radio disturbance by other appliances which generate high inte...

Страница 25: ...placing sealing cap Optional accessory If the sealing cap is worn out the performance of the dust collection decreases Replace it if it s worn out Remove the sealing cap and then attach a new one with its protrusion facing upward Fig 58 1 Protrusion 2 Sealing cap OPTIONAL ACCESSORIES CAUTION These accessories or attachments are recommended for use with your Makita tool specified in this manual The...