Accidental re-start preventive function

When installing the battery cartridge while pulling the 

switch lever, the tool does not start.

To start the tool, first release the switch lever. Then pull 

the lock-off lever, and pull the switch lever.

Electronic torque control function

The tool electronically detects situations where the wheel or 

accessory may be at risk to be bound. In the situation, the 

tool is automatically shut off to prevent further rotation of the 

spindle (it does not prevent kickback).

To restart the tool, switch off the tool first, remove the 

cause of sudden drop in the rotation speed, and then 

turn the tool on.

Soft start feature

Soft start feature reduces starting reaction.

Electric brake

Electric brake is activated after the tool is switched off.

The brake does not work when the power supply is shut 

down, such as the battery is removed accidentally, with 

the switch still on.

ASSEMBLY

CAUTION:

 

Always be sure that the tool is 

switched off and the battery cartridge is removed 

before adjusting or checking function on the tool.

Installing side grip (handle)

CAUTION:

 

Always be sure that the side grip is 

installed securely before operation.

Screw the side grip securely on the position of the tool 

as shown in the figure.

► 

Fig.5

Installing or removing wheel guard 

(For depressed center wheel, flap 

disc, flex wheel, wire wheel brush 

/ abrasive cut-off wheel, diamond 

wheel)

When using a depressed center  

wheel / flap disc / flex wheel / wire 

wheel brush

WARNING:

 

The wheel guard must be fitted 

on the tool so that the closed side of the guard 

always points toward the operator.

Loosen the nut, and then pull the lever in the direction 

of the arrow.

► 

Fig.6:

    

1.

 Nut 

2.

 Lever

Mount the wheel guard with the protrusions on the 

wheel guard band aligned with the notches on the bear

-

ing box. Then rotate the wheel guard to such an angle 

that it can protect the operator according to work.

► 

Fig.7:

    

1.

 Wheel guard 

2.

 Bearing box

► 

Fig.8:

    

1.

 Wheel guard

Securely tighten the nut using a spanner, and then close the 

lever in direction of the arrow to fasten the wheel guard. If the 

lever is too tight or too loose to fasten the wheel guard, open 

the lever and then loosen or tighten the nut using the spanner 

to adjust the tightening of the wheel guard band.

► 

Fig.9:

    

1.

 Nut 

2.

 Lever

To remove wheel guard, follow the installation proce

-

dure in reverse.

When using an abrasive cut-off / 

diamond wheel

Optional accessory

WARNING:

 

Be sure to use only the special 

wheel guard designed for use with cut-off wheels.

(In some European countries, when using a diamond 

wheel, the ordinary guard can be used. Follow the 

regulations in your country.)

Mount the wheel guard with the protrusions on the 

wheel guard band aligned with the notches on the bear

-

ing box. Then rotate the wheel guard to such an angle 

that it can protect the operator according to work. Be 

sure to tighten the screw securely.

To remove wheel guard, follow the installation proce

-

dure in reverse.

► 

Fig.10:

    

1.

 Wheel guard 

2.

 Bearing box 

3.

 Screw

Installing or removing depressed 

center wheel or flap disc

Optional accessory

WARNING:

 

When using a depressed center 

wheel or flap disc, the wheel guard must be fitted 

on the tool so that the closed side of the guard 

always points toward the operator.

CAUTION:

 

Make sure that the mounting part 

of the inner flange fits into the inner diameter of 

the depressed center wheel / flap disc perfectly.

 

Mounting the inner flange on the wrong side may 

result in the dangerous vibration.

Mount the inner flange onto the spindle.

Make sure to fit the dented part of the inner flange onto 

the straight part at the bottom of the spindle.

Fit the wheel/ disc on the inner flange and screw the 

lock nut with its protrusion facing downward (facing 

towards the wheel).

► 

Fig.11:

    

1.

 Lock nut 

2.

 Depressed center wheel 

3.

 Inner flange 

4.

 Mounting part

To tighten the lock nut, press the shaft lock firmly so 

that the spindle cannot revolve, then use the lock nut 

wrench and securely tighten clockwise.

► 

Fig.12:

    

1.

 Lock nut wrench 

2.

 Shaft lock

To remove the wheel, follow the installation procedure 

in reverse.

Содержание GA038G XGT

Страница 1: ...liper BRUKSANVISNING 39 FI Akkukäyttöinen kulmahiomakone KÄYTTÖOHJE 54 DA Ledningsfri vinkelsliber BRUGSANVISNING 69 LV Bezvada leņķa slīpmašīna LIETOŠANAS INSTRUKCIJA 84 LT Belaidis kampinis šlifuoklis NAUDOJIMO INSTRUKCIJA 100 ET Juhtmeta nurklihvija KASUTUSJUHEND 116 RU Аккумуляторная угловая шлифмашина РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ 131 ...

Страница 2: ...1 2 3 Fig 1 1 2 Fig 2 1 Fig 3 1 2 Fig 4 Fig 5 1 2 Fig 6 1 2 Fig 7 1 Fig 8 2 ...

Страница 3: ...1 2 Fig 9 1 3 2 Fig 10 1 2 3 4 Fig 11 1 2 Fig 12 1 2 3 4 Fig 13 1 2 3 Fig 14 1 2 3 4 Fig 15 1 Fig 16 3 ...

Страница 4: ...1 2 Fig 17 Fig 18 1 2 3 4 Fig 19 1 2 3 5 4 ø45 ø78 ø78 Fig 20 1 Fig 21 1 Fig 22 1 2 3 4 5 6 7 Fig 23 1 2 Fig 24 4 ...

Страница 5: ...Fig 25 Fig 26 Fig 27 Fig 28 Fig 29 Fig 30 1 Fig 31 1 2 3 4 Fig 32 5 ...

Страница 6: ...1 2 3 Fig 33 1 Fig 34 1 1 2 2 Fig 35 Fig 36 1 Fig 37 6 ...

Страница 7: ...1 2 Fig 38 1 Fig 39 1 Fig 40 1 1 2 2 Fig 41 1 2 Fig 42 1 Fig 43 7 ...

Страница 8: ...1 2 3 4 5 2 3 6 7 8 9 10 2 11 12 13 14 17 5 15 16 18 19 16 5 20 21 3 5 22 5 Fig 44 8 ...

Страница 9: ...ound pressure level LpA 88 dB A Sound power level LWA 99 dB A Uncertainty K 3 dB A Model GA038G Sound pressure level LpA 87 dB A Sound power level LWA 98 dB A Uncertainty K 3 dB A NOTE The declared noise emission value s has been measured in accordance with a standard test method and may be used for comparing one tool with another NOTE The declared noise emission value s may also be used in a prel...

Страница 10: ...injury 2 Operations such as polishing are not recommended to be performed with this power tool Operations for which the power tool was not designed may create a hazard and cause personal injury 3 Do not use accessories which are not specifically designed and recommended by the tool manufac turer Just because the accessory can be attached to your power tool it does not assure safe operation 4 The r...

Страница 11: ...nd are unsafe 2 The grinding surface of centre depressed wheels must be mounted below the plane of the guard lip An improperly mounted wheel that projects through the plane of the guard lip cannot be adequately protected 3 The guard must be securely attached to the power tool and positioned for maximum safety so the least amount of wheel is exposed towards the operator The guard helps to protect t...

Страница 12: ...el guard required by domestic regulation 19 Cutting discs must not be subjected to any lateral pressure 20 Do not use cloth work gloves during operation Fibers from cloth gloves may enter the tool which causes tool breakage 21 Make sure there are no electrical cables water pipes gas pipes etc that could cause a hazard if damaged by use of the tool SAVE THESE INSTRUCTIONS WARNING DO NOT let comfort...

Страница 13: ...rain or wet conditions 5 Do not use the wireless unit in places where the temperature exceeds 50 C 122 F 6 Do not operate the wireless unit in places where medical instruments such as heart pace makers are nearby 7 Do not operate the wireless unit in places where automated devices are nearby If operated automated devices may develop malfunction or error 8 Do not operate the wireless unit in places...

Страница 14: ...l blink when the battery protection system works Tool battery protection system The tool is equipped with a tool battery protection sys tem This system automatically cuts off power to the motor to extend tool and battery life The tool will auto matically stop during operation if the tool or battery is placed under one of the following conditions Overload protection When the tool battery is operate...

Страница 15: ...x Fig 8 1 Wheel guard Securely tighten the nut using a spanner and then close the lever in direction of the arrow to fasten the wheel guard If the lever is too tight or too loose to fasten the wheel guard open the lever and then loosen or tighten the nut using the spanner to adjust the tightening of the wheel guard band Fig 9 1 Nut 2 Lever To remove wheel guard follow the installation proce dure i...

Страница 16: ...and turn Ezynut counterclockwise Fig 17 1 Arrow 2 Notch Fig 18 Installing abrasive cut off diamond wheel Optional accessory WARNING When using an abrasive cut off diamond wheel be sure to use only the special wheel guard designed for use with cut off wheels In some European countries when using a diamond wheel the ordinary guard can be used Follow the regulations in your country WARNING NEVER use ...

Страница 17: ... etc This can cause loss of control and kickback WARNING NEVER use tool with wood cutting blades and other saw blades Such blades when used on a grinder frequently kick and cause loss of control leading to personal injury CAUTION Never switch on the tool when it is in contact with the workpiece it may cause an injury to operator CAUTION Always wear safety goggles or a face shield during operation ...

Страница 18: ...ory CAUTION Place the tool on a flat and stable surface when installing the wireless unit NOTICE Clean the dust and dirt on the tool before installing the wireless unit Dust or dirt may cause malfunction if it comes into the slot of the wireless unit NOTICE To prevent the malfunction caused by static touch a static discharging material such as a metal part of the tool before picking up the wireles...

Страница 19: ...ation NOTE Refer to the instruction manual of the vacuum cleaner too After registering a tool to the vacuum cleaner the vacuum cleaner will automatically runs along with the switch operation of the tool 1 Install the wireless unit to the tool 2 Connect the hose of the vacuum cleaner with the tool Fig 36 3 Set the stand by switch on the vacuum cleaner to AUTO Fig 37 1 Stand by switch 4 Push the wir...

Страница 20: ...vation lamp will start blinking in blue Others Red 3 seconds The power is supplied to the wireless unit and the wireless activa tion function is starting up Off The wireless activation of the vacuum cleaner is stopped Cancelling tool registration for the vacuum cleaner Perform the following procedure when cancelling the tool registration for the vacuum cleaner 1 Install the batteries to the vacuum...

Страница 21: ...ed into the tool Install the wireless unit correctly The terminal of the wireless unit and or the slot is dirty Gently wipe off dust and dirt on the terminal of the wireless unit and clean the slot The stand by switch on the vacuum cleaner is not set to AUTO Set the stand by switch on the vacuum cleaner to AUTO No power supply Supply the power to the tool and the vacuum cleaner Incorrect operation...

Страница 22: ...ission distance is approxi mately 10 m however it may vary according to the circumstances Radio disturbance by other appliances which generate high intensity radio waves Keep the tool and vacuum cleaner away from the appliances such as Wi Fi devices and microwave ovens The vacuum cleaner runs while the tool s switch trigger is not pulled Other users are using the wireless activation of the vacuum ...

Страница 23: ...r flange 1 Inner flange 78 Australia and New Zealand only 3 15 Abrasive cut off wheel 16 Diamond wheel 17 Outer flange 78 Australia and New Zealand only 3 18 Side grip for dust collecting wheel guard 19 Dust collecting wheel guard 4 20 Special flange 5 21 Dust collecting wheel guard for offset diamond wheel 22 Offset diamond wheel Lock nut wrench NOTE 1 Only for tools with M14 spindle thread NOTE ...

Отзывы: