Troubleshooting
Condition
Possible Cause
Solution
The pump does not start.
1. The battery is not set properly.
2. The ambient temperature is too low.
3. Poor wiring connection.
4. The pump is locked.
5. Motor failure.
1. Set the battery properly.
2. Warm up the pump in doors.
3. Repair.
4. Repair.
5. Repair.
The pump does not enough vacuum.
1. Leaking from the system.
2. Insufficient oil.
3. Dirty oil.
4. Pump parts are worn out.
5. Damaged fittings, gaskets and seal.
6. Motor failure.
1. Repair the system.
2. Refill or change oil.
3. Clean the tank and change oil.
4. Repair.
5. Repair.
6. Repair.
Oil leakage
1. Damaged gaskets and shaft seals.
2. Damaged O-ring of oil drain valve.
3. Oil drain valve is loose.
1. Repair.
2. Replace O-ring.
3. Tighten Oil drain valve.
Abnormal noise
1. Motor failure.
2. Bearing failure.
3. Loose bolts.
4. Pump failure.
5. Air is sucked.
1. Repair.
2. Repair.
3. Tighten bolts.
4. Repair.
5. Tighten caps and connections.
Replace gaskets and O-rings.
Replace fittings or re-seal them.
Remark: If these procedures do not solve the problem, contact with your nearest Makita authorized distributor or send
your pump to our service center.
OPTIONAL
ACCESSORIES
CAUTION:
These accessories or attachments
are recommended for use with your Makita tool
specified in this manual.
The use of any other
accessories or attachments might present a risk of
injury to persons. Only use accessory or attachment for
its stated purpose.
If you need any assistance for more details regarding
these accessories, ask your local Makita Service Center.
•
Shoulder belt
•
Vacuum pump oil 300 ml
•
Vacuum pump hose
•
Vacuum pump valve with gauge
•
Makita genuine batteries and chargers
CAUTION:
When using the shoulder belt:
—
Do not use the shoulder belt if the hook is
damaged or deformed.
—
The hooks are intended to use with Makita
shoulder belt only. Do not attach any other
attachment.
Using for unintended purpose may
cause accident or personal injury.
—
The shoulder belt is intended for carrying
the pump on your shoulder. Do not use it for
other purposes such as anti-drop measure.
—
Do not put excessive load to the shoulder
belt.
Doing so may break the shoulder belt or
mounting part and result in personal injury.
—
When using the shoulder belt, attach it to
the hooks on the handle. Make sure that
the shoulder belt is securely attached to the
hooks and hold the handle of the pump when
carrying it using the shoulder belt.
NOTE:
Some items in the list may be included in the
tool package as standard accessories. They may differ
from country to country.