Vibration

The vibration total value (tri-axial vector sum) deter

-

mined according to EN62841-2-5:

Model DHS782

Work mode: cutting wood

Vibration emission (a

h,W

) : 2.5 m/s

2

 or less

Uncertainty (K) : 1.5 m/s

2

Work mode: cutting metal

Vibration emission (a

h,M

) : 2.5 m/s

2

 or less

Uncertainty (K) : 1.5 m/s

2

Model DHS783

Work mode: cutting wood

Vibration emission (a

h,W

) : 2.5 m/s

2

 or less

Uncertainty (K) : 1.5 m/s

2

Work mode: cutting metal

Vibration emission (a

h,M

) : 2.5 m/s

2

 or less

Uncertainty (K) : 1.5 m/s

2

NOTE:

 The declared vibration total value(s) has been 

measured in accordance with a standard test method 

and may be used for comparing one tool with another.

NOTE:

 The declared vibration total value(s) may also 

be used in a preliminary assessment of exposure.

WARNING:

 

The vibration emission during 

actual use of the power tool can differ from the 

declared value(s) depending on the ways in which 

the tool is used especially what kind of workpiece 

is processed.

WARNING:

 

Be sure to identify safety mea-

sures to protect the operator that are based on an 

estimation of exposure in the actual conditions of 

use (taking account of all parts of the operating 

cycle such as the times when the tool is switched 

off and when it is running idle in addition to the 

trigger time).

EC Declaration of Conformity

For European countries only

The EC declaration of conformity is included as Annex A 

to this instruction manual.

SAFETY WARNINGS

General power tool safety warnings

WARNING:

 

Read all safety warnings, instruc-

tions, illustrations and specifications provided 

with this power tool.

 Failure to follow all instructions 

listed below may result in electric shock, fire and/or 

serious injury.

Save all warnings and instruc-

tions for future reference.

The term "power tool" in the warnings refers to your 

mains-operated (corded) power tool or battery-operated 

(cordless) power tool.

Work area safety

1. 

Keep work area clean and well lit.

 Cluttered or 

dark areas invite accidents.

2. 

Do not operate power tools in explosive atmo-

spheres, such as in the presence of flammable 

liquids, gases or dust.

 Power tools create sparks 

which may ignite the dust or fumes.

3. 

Keep children and bystanders away while 

operating a power tool.

 Distractions can cause 

you to lose control.

Electrical Safety

1. 

Power tool plugs must match the outlet. Never modify 

the plug in any way. Do not use any adapter plugs 

with earthed (grounded) power tools. 

Unmodified plugs 

and matching outlets will reduce risk of electric shock.

2. 

Avoid body contact with earthed or grounded 

surfaces, such as pipes, radiators, ranges and 

refrigerators.

 There is an increased risk of elec-

tric shock if your body is earthed or grounded.

3. 

Do not expose power tools to rain or wet con-

ditions.

 Water entering a power tool will increase 

the risk of electric shock.

4. 

Do not abuse the cord. Never use the cord for 

carrying, pulling or unplugging the power tool. 

Keep cord away from heat, oil, sharp edges 

or moving parts.

 Damaged or entangled cords 

increase the risk of electric shock.

5. 

When operating a power tool outdoors, use an 

extension cord suitable for outdoor use.

 Use of a cord 

suitable for outdoor use reduces the risk of electric shock.

6. 

If operating a power tool in a damp location 

is unavoidable, use a residual current device 

(RCD) protected supply.

 Use of an RCD reduces 

the risk of electric shock.

7. 

Power tools can produce electromagnetic fields 

(EMF) that are not harmful to the user.

 However, 

users of pacemakers and other similar medical 

devices should contact the maker of their device and/

or doctor for advice before operating this power tool.

Personal Safety

1. 

Stay alert, watch what you are doing and use 

common sense when operating a power tool. 

Do not use a power tool while you are tired or 

under the influence of drugs, alcohol or med-

ication.

 A moment of inattention while operating 

power tools may result in serious personal injury.

2. 

Use personal protective equipment. Always 

wear eye protection.

 Protective equipment such 

as a dust mask, non-skid safety shoes, hard hat or 

hearing protection used for appropriate conditions 

will reduce personal injuries.

3. 

Prevent unintentional starting. Ensure the 

switch is in the off-position before connecting 

to power source and/or battery pack, picking 

up or carrying the tool.

 Carrying power tools with 

your finger on the switch or energising power tools 

that have the switch on invites accidents.

4. 

Remove any adjusting key or wrench before 

turning the power tool on.

 A wrench or a key left 

attached to a rotating part of the power tool may 

result in personal injury.

5. 

Do not overreach. Keep proper footing and 

balance at all times.

 This enables better control 

of the power tool in unexpected situations.

Содержание DHS783ZJU

Страница 1: ...INSTRUCTION MANUAL Cordless Circular Saw DHS782 DHS783 ENGLISH Original instructions Read before use ...

Страница 2: ...quipment and Batteries and Accumulators and Waste Batteries and Accumulators and their implementation in accordance with national laws electric equipment and batteries and battery pack s that have reached the end of their life must be col lected separately and returned to an envi ronmentally compatible recycling facility Intended use The tool is intended for performing lengthways and crossways str...

Страница 3: ...ctrical Safety 1 Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock 2 Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of elec tric shock if your body is earthed o...

Страница 4: ...ss likely to bind and are easier to control 7 Use the power tool accessories and tool bits etc in accordance with these instructions tak ing into account the working conditions and the work to be performed Use of the power tool for operations different from those intended could result in a hazardous situation 8 Keep handles and grasping surfaces dry clean and free from oil and grease Slippery hand...

Страница 5: ...closing down the blade stalls and the motor reaction drives the unit rapidly back toward the operator if the blade becomes twisted or misaligned in the cut the teeth at the back edge of the blade can dig into the top surface of the wood causing the blade to climb out of the kerf and jump back toward the operator Kickback is the result of saw misuse and or incorrect operating procedures or conditio...

Страница 6: ...d as soon as the blade enters the material the lower guard must be released For all other sawing the lower guard should operate automatically 4 Always observe that the lower guard is cover ing the blade before placing the saw down on bench or floor An unprotected coasting blade will cause the saw to walk backwards cutting whatever is in its path Be aware of the time it takes for the blade to stop ...

Страница 7: ...ven a breakdown 6 Do not store the tool and battery cartridge in locations where the temperature may reach or exceed 50 C 122 F 7 Do not incinerate the battery cartridge even if it is severely damaged or is completely worn out The battery cartridge can explode in a fire 8 Be careful not to drop or strike battery 9 Do not use a damaged battery 10 The contained lithium ion batteries are subject to t...

Страница 8: ...ireless unit gently wipe with a dry soft cloth Do not use benzine thin ner conductive grease or the like 25 When storing the wireless unit keep it in the supplied case or a static free container 26 Do not insert any devices other than Makita wireless unit into the slot on the tool 27 Do not use the tool with the lid of the slot dam aged Water dust and dirt come into the slot may cause malfunction ...

Страница 9: ...tomatically and the battery indicator blink about 60 seconds In this situ ation let the tool cool down before turning the tool on again On Blinking Overdischarge protection When the battery capacity becomes low the tool stops automatically If the product does not operate even when the switches are operated remove the batteries from the tool and charge the batteries Indicating the remaining battery...

Страница 10: ... firmly to respond the reaction of the brake when releasing the switch trigger Sudden reaction can drop the tool off your hand and can cause a personal injury Automatic speed change function This tool has high speed mode and high torque mode The tool automatically changes the operation mode depending on the work load When the work load is low the tool will run in the high speed mode for quicker cu...

Страница 11: ...g line 45 position Lighting the lamp CAUTION Do not look in the light or see the source of light directly To turn on the lamp without running the tool pull the switch trigger without pressing the lock off button To turn on the lamp with the tool running press and hold the lock off button and pull the switch trigger The lamp goes out 10 seconds after releasing the switch trigger 1 1 Lamp NOTE Use a...

Страница 12: ... switch lever release have tool serviced at a Makita service center CAUTION The blade brake system is not a substitute for blade guard NEVER USE TOOL WITHOUT A FUNCTIONING BLADE GUARD SERIOUS PERSONAL INJURY CAN RESULT Electronic function The tools equipped with electronic function are easy to operate because of the following feature s Soft start feature Soft start because of suppressed starting s...

Страница 13: ... follow the removal procedure in reverse For tool with the inner flange for other than 15 88 mm hole diameter saw blade The inner flange has a certain diameter protrusion on one side of it and a different diameter protrusion on the other side Choose a correct side on which protrusion fits into the saw blade hole perfectly Mount the inner flange onto the mounting shaft so that the correct side of p...

Страница 14: ... move ment and severe vibration resulting in possible loss of control during operation and in serious personal injury Blade guard cleaning When changing the circular saw blade make sure to also clean the upper and lower blade guards of accu mulated sawdust as discussed in the Maintenance section Such efforts do not replace the need to check lower guard operation before each use Connecting a vacuum...

Страница 15: ...flat and advancing smoothly until the sawing is completed To get clean cuts keep your sawing line straight and your speed of advance uniform If the cut fails to properly follow your intended cut line do not attempt to turn or force the tool back to the cut line Doing so may bind the circular saw blade and lead to dangerous kickback and possible serious injury Release switch wait for circular saw b...

Страница 16: ...held securely 8 Attach the lanyard so that the tool will move away from the operator if it falls Dropped tools will swing on the lanyard which could cause injury or loss of balance 9 Do not use near moving parts or running machinery Failure to do so may result in a crush or entanglement hazard 10 Do not carry the tool by the attachment device or the lanyard 11 Only transfer the tool between your h...

Страница 17: ...e wireless unit align the projections with the recessed portions on the slot 1 3 4 2 1 Wireless unit 2 Projection 3 Lid 4 Recessed portion When removing the wireless unit open the lid slowly The hooks on the back of the lid will lift the wireless unit as you pull up the lid 2 1 3 1 Wireless unit 2 Hook 3 Lid After removing the wireless unit keep it in the supplied case or a static free container N...

Страница 18: ... button on the tool while the wireless acti vation lamp on the cleaner is blinking If the wireless activation lamp does not blink in green push the wire less activation button briefly and hold it down again NOTE When performing two or more tool registra tions for one vacuum cleaner finish the tool registra tion one by one Starting the wireless activation function NOTE Finish the tool registration ...

Страница 19: ...eless activation function Description of the wireless activation lamp status 1 1 Wireless activation lamp The wireless activation lamp shows the status of the wireless activation function Refer to the table below for the meaning of the lamp status Status Wireless activation lamp Description Color On Blinking Duration Standby Blue 2 hours The wireless activation of the vacuum cleaner is available T...

Страница 20: ...nd then become red After that press the wireless activation button on the tool in the same way 1 2 2 1 1 Wireless activation button 2 Wireless activation lamp If the cancellation is performed successfully the wire less activation lamps will light up in red for 2 seconds and start blinking in blue NOTE The wireless activation lamps finish blinking in red after 20 seconds elapsed Press the wireless ...

Страница 21: ...power button on the vacuum cleaner is turned on Push the wireless activation button briefly and perform the tool registration cancellation procedures again The tool registration procedures for the tool or vacuum cleaner have not finished Perform the tool registration procedures for both the tool and the vacuum cleaner at the same timing Radio disturbance by other appliances which generate high int...

Страница 22: ...rvice Centers always using Makita replacement parts Adjusting 0 cut or 45 cut accuracy This adjustment has been made at the factory But if it is off you can adjust it as the following procedure 1 Loosen the clamping screws on the front and rear of the tool so that the bevel angle can be changed Set the stopper to 0 45 bevel angle position if you are going to adjust 45 cut accuracy 1 1 Stopper 2 Ma...

Страница 23: ...er accessories or attachments might present a risk of injury to persons Only use accessory or attachment for its stated purpose If you need any assistance for more details regard ing these accessories ask your local Makita Service Center Circular saw blade Rip fence Guide rule Hook Guide rail Bevel guide Clamp Sheet Rubber sheet Position sheet Dust nozzle Hex wrench Wireless unit for DHS783 Makita...

Страница 24: ...www makita com Makita Europe N V Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan Jan Baptist Vinkstraat 2 3070 Kortenberg Belgium 885699 226 EN 20190108 ...

Отзывы: