Troubleshooting for wireless activation function

Before asking for repairs, conduct your own inspection first. If you find a problem that is not explained in the manual, 

do not attempt to dismantle the tool. Instead, ask Makita Authorized Service Centers, always using Makita replace-

ment parts for repairs.

State of abnormality

Probable cause (malfunction)

Remedy

The wireless activation lamp does 

not light/blink.

The wireless unit is not installed into the tool. 

The wireless unit is improperly installed 

into the tool.

Install the wireless unit correctly.

The terminal of the wireless unit and/or 

the slot is dirty.

Gently wipe off dust and dirt on the terminal of the 

wireless unit and clean the slot.

The wireless activation button on the 

tool has not been pushed.

Push the wireless activation button on the tool 

briefly.

The stand-by switch on the vacuum 

cleaner is not set to "AUTO".

Set the stand-by switch on the vacuum cleaner to 

"AUTO".

No power supply

Supply the power to the tool and the vacuum cleaner.

Cannot finish tool registration / can

-

celling tool registration successfully.

The wireless unit is not installed into the tool. 

The wireless unit is improperly installed 

into the tool.

Install the wireless unit correctly.

The terminal of the wireless unit and/or 

the slot is dirty.

Gently wipe off dust and dirt on the terminal of the 

wireless unit and clean the slot.

The stand-by switch on the vacuum 

cleaner is not set to "AUTO".

Set the stand-by switch on the vacuum cleaner to 

"AUTO".

No power supply

Supply the power to the tool and the vacuum cleaner.

Incorrect operation

Push the wireless activation button briefly and perform 

the tool registration/cancellation procedures again.

The tool and vacuum cleaner are away 

from each other (out of the transmission 

range).

Get the tool and vacuum cleaner closer to each other. 

The maximum transmission distance is approximately 10 

m however it may vary according to the circumstances.

Before finishing the tool registration/

cancellation; 

- the switch trigger on the tool is pulled or;  

- the power button on the vacuum 

cleaner is turned on.

Push the wireless activation button briefly and 

perform the tool registration/cancellation procedures 

again.

The tool registration procedures for the 

tool or vacuum cleaner has not finished.

Perform the tool registration procedures for both the 

tool and the vacuum cleaner at the same timing.

Radio disturbance by other appliances 

which generate high-intensity radio waves.

Keep the tool and vacuum cleaner away from the appli-

ances such as Wi-Fi devices and microwave ovens.

The vacuum cleaner does not run 

along with the switch operation of 

the tool.

The wireless unit is not installed into the tool. 

The wireless unit is improperly installed 

into the tool.

Install the wireless unit correctly.

The terminal of the wireless unit and/or 

the slot is dirty.

Gently wipe off dust and dirt on the terminal of the 

wireless unit and clean the slot.

The wireless activation button on the 

tool has not been pushed.

Push the wireless activation button briefly and make 

sure that the wireless activation lamp is blinking in blue.

The stand-by switch on the vacuum 

cleaner is not set to "AUTO".

Set the stand-by switch on the vacuum cleaner to 

"AUTO".

More than 10 tools are registered to the 

vacuum cleaner.

Perform the tool registration again. 

If more than 10 tools are registered to the vacuum cleaner, 

the tool registered earliest will be cancelled automatically.

The vacuum cleaner erased all tool 

registrations.

Perform the tool registration again.

No power supply

Supply the power to the tool and the vacuum cleaner.

The tool and vacuum cleaner are away 

from each other (out of the transmission 

range).

Get the tool and vacuum cleaner closer each other. 

The maximum transmission distance is approxi-

mately 10 m however it may vary according to the 

circumstances.

Radio disturbance by other appliances 

which generate high-intensity radio 

waves.

Keep the tool and vacuum cleaner away from the 

appliances such as Wi-Fi devices and microwave 

ovens.

The vacuum cleaner runs while the 

tool's switch trigger is not pulled.

Other users are using the wireless 

activation of the vacuum cleaner with 

their tools.

Turn off the wireless activation button of the other 

tools or cancel the tool registration of the other 

tools.

Содержание DHR283

Страница 1: ...INSTRUCTION MANUAL Cordless Combination Hammer DHR280 DHR281 DHR282 DHR283 ENGLISH Original instructions Read before use ...

Страница 2: ... show the symbols used for the equipment Be sure that you understand their meaning before use Read instruction manual Ni MH Li ion Only for EU countries Do not dispose of electric equipment or battery pack together with household waste material In observance of the European Directives on Waste Electric and Electronic Equipment and Batteries and Accumulators and Waste Batteries and Accumulators and...

Страница 3: ... 5 m s 2 Work mode chiselling function with side grip Vibration emission ah Cheq 8 5 m s 2 Uncertainty K 1 5 m s 2 Work mode drilling into metal Vibration emission ah D 2 5 m s 2 Uncertainty K 1 5 m s 2 NOTE The declared vibration emission value has been measured in accordance with the standard test method and may be used for comparing one tool with another NOTE The declared vibration emission val...

Страница 4: ...s ensure these are connected and properly used Use of dust collection can reduce dust related hazards 8 Do not let familiarity gained from frequent use of tools allow you to become complacent and ignore tool safety principles A careless action can cause severe injury within a fraction of a second 9 Always wear protective goggles to protect your eyes from injury when using power tools The goggles m...

Страница 5: ...eld Ordinary eye or sun glasses are NOT safety glasses It is also highly recommended that you wear a dust mask and thickly padded gloves 5 Be sure the bit is secured in place before operation 6 Under normal operation the tool is designed to produce vibration The screws can come loose easily causing a breakdown or accident Check tightness of screws carefully before operation 7 In cold weather or wh...

Страница 6: ...rature exceeds 50 C 122 F 6 Do not operate the wireless unit in places where medical instruments such as heart pace makers are near by 7 Do not operate the wireless unit in places where automated devices are near by If oper ated automated devices may develop malfunction or error 8 Do not operate the wireless unit in places under high temperature or places where static electricity or electrical noi...

Страница 7: ...ntally fall out of the tool causing injury to you or someone around you CAUTION Do not install the battery cartridge forcibly If the cartridge does not slide in easily it is not being inserted correctly Indicating the remaining battery capacity Only for battery cartridges with the indicator 1 2 1 Indicator lamps 2 Check button Press the check button on the battery cartridge to indi cate the remain...

Страница 8: ...4 810 4 130 3 640 3 260 2 470 2 400 1 300 1 550 CAUTION Do not turn the adjusting dial when the tool is running Failure to do so may result in the loss of control of the tool and cause an injury NOTICE If the tool is operated continuously at low speed for a long time the motor will get over loaded resulting in tool malfunction NOTICE The speed adjusting dial can be turned only as far as 5 and back...

Страница 9: ...ide for clockwise rotation or from the B side for coun terclockwise rotation When the reversing switch lever is in the neutral posi tion the switch trigger cannot be pulled Changing the quick change chuck for SDS plus For DHR281 DHR283 The quick change chuck for SDS plus can be easily exchanged for the quick change drill chuck Removing the quick change chuck for SDS plus CAUTION Before removing th...

Страница 10: ...ith hammering 2 Action mode chang ing knob Rotation only For drilling in wood metal or plastic materials rotate the action mode changing knob to the symbol Use a twist drill bit or wood drill bit 1 1 Rotation only Hammering only For chipping scaling or demolition operations rotate the action mode changing knob to the symbol Use a bull point cold chisel scaling chisel etc 1 1 Hammering only Hook CA...

Страница 11: ...hole saw which tend to pinch or catch easily in the hole are not appro priate for this tool This is because they will cause the torque limiter to actuate too frequently The torque limiter will actuate when a certain torque level is reached The motor will disengage from the output shaft When this happens the drill bit will stop turning Electronic function The tool is equipped with the electronic fu...

Страница 12: ...tool barrel 1 1 Thumb screw 3 Tighten the thumb screw to secure the grip The grip can be fixed at desired angle Grease Coat the shank end of the drill bit beforehand with a small amount of grease about 0 5 1 g This chuck lubrication assures smooth action and lon ger service life Installing or removing drill bit Clean the shank end of the drill bit and apply grease before installing the drill bit 1...

Страница 13: ... gauge into the hex hole Make sure that the toothed side of the depth gauge faces the marking 1 2 4 3 1 Depth gauge 2 Lock button 3 Marking 4 Toothed side Adjust the depth gauge by moving it back and forth while pressing the lock button After the adjustment release the lock button to lock the depth gauge NOTE Make sure that the depth gauge does not touch the main body of the tool when attaching it...

Страница 14: ... cup set remove the bit from the tool if installed Install the dust cup set on the tool so that the sym bol on the dust cup is aligned with the groove in the tool 1 2 1 symbol 2 Groove NOTE If you connect a vacuum cleaner to the dust cup set remove the dust cap before connecting it 1 1 Dust cap To remove the dust cup set remove the bit while pulling the chuck cover in the direction of the arrow 1 ...

Страница 15: ...e tool s capability Hammer drilling operation CAUTION There is tremendous and sudden twisting force exerted on the tool drill bit at the time of hole break through when the hole becomes clogged with chips and particles or when striking reinforcing rods embedded in the concrete Always use the side grip auxiliary handle and firmly hold the tool by both side grip and switch handle during opera tions ...

Страница 16: ...283 Use the quick change drill chuck as standard equip ment When installing it refer to changing the quick change chuck for SDS plus Hold the ring and turn the sleeve counterclockwise to open the chuck jaws Place the bit in the chuck as far as it will go Hold the ring firmly and turn the sleeve clock wise to tighten the chuck 1 2 1 Sleeve 2 Ring To remove the bit hold the ring and turn the sleeve ...

Страница 17: ...nce of dust collection decreases if the filter in the dust case become clogged Replace the filter with new one after approximately 200 times of dust fulfillment as a guide Failure to do so may cause dust inhalation 1 Remove the dust case while pressing down the lever of the dust case 1 1 Lever 2 Open the cover of the dust case 1 1 Cover 3 Dispose of the dust and then clean the filter NOTICE When c...

Страница 18: ...on The overview of the wireless activation function setting is as follows Refer to each section for detail procedures 1 Installing the wireless unit 2 Tool registration for the vacuum cleaner 3 Starting the wireless activation function Installing the wireless unit Optional accessory CAUTION Place the tool on a flat and stable surface when installing the wireless unit NOTICE Clean the dust and dirt...

Страница 19: ...ol registration NOTE During the tool registration do not pull the switch trigger or turn on the power switch on the vacuum cleaner NOTE Refer to the instruction manual of the vacuum cleaner too If you wish to activate the vacuum cleaner along with the switch operation of the tool finish the tool registra tion beforehand 1 Install the batteries to the vacuum cleaner and the tool 2 Set the stand by ...

Страница 20: ...m cleaner to AUTO 1 1 Stand by switch 4 Push the wireless activation button on the tool briefly The wireless activation lamp will blink in blue 1 2 1 Wireless activation button 2 Wireless activation lamp 5 Pull the switch trigger of the tool Check if the vacuum cleaner runs while the switch trigger is being pulled To stop the wireless activation of the vacuum cleaner push the wireless activation b...

Страница 21: ...uum cleaner is available and the tool is running Tool registration Green 20 seconds Ready for the tool registration Waiting for the registration by the vacuum cleaner 2 seconds The tool registration has been finished The wireless activation lamp will start blinking in blue Cancelling tool registration Red 20 seconds Ready for the cancellation of the tool registration Waiting for the cancellation b...

Страница 22: ...nd then become red After that press the wireless activation button on the tool in the same way 1 2 1 2 1 Wireless activation button 2 Wireless activation lamp If the cancellation is performed successfully the wire less activation lamps will light up in red for 2 seconds and start blinking in blue NOTE The wireless activation lamps finish blinking in red after 20 seconds elapsed Press the wireless ...

Страница 23: ...power button on the vacuum cleaner is turned on Push the wireless activation button briefly and perform the tool registration cancellation procedures again The tool registration procedures for the tool or vacuum cleaner has not finished Perform the tool registration procedures for both the tool and the vacuum cleaner at the same timing Radio disturbance by other appliances which generate high inte...

Страница 24: ...1 Remove the dust case while pressing down the lever of the dust case 1 1 Lever 2 Insert the flat blade screwdriver into the slots of the filter cover to remove the filter cover 2 1 1 Flat blade screwdriver 2 Filter cover 3 Remove the filter from the filter case 1 2 1 Filter 2 Filter case 4 Attach a new filter to the filter case and then attach the filter cover 5 Close the cover of the dust case a...

Страница 25: ...ls regard ing these accessories ask your local Makita Service Center Carbide tipped drill bits SDS Plus carbide tipped bits Core bit Bull point Diamond core bit Cold chisel Scaling chisel Grooving chisel Chuck adapter Keyless drill chuck Bit grease Depth gauge Blow out bulb Dust cup Dust cup set Dust collection system Wireless unit Makita genuine battery and charger Safety goggles Plastic carrying...

Страница 26: ...26 ...

Страница 27: ...27 ...

Страница 28: ...www makita com Makita Europe N V Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan Jan Baptist Vinkstraat 2 3070 Kortenberg Belgium 885632B228 EN 20180601 ...

Отзывы: