P 6 / 6
W
iring diagram
[2] Wiring in Handle
Be sure to connect so that all slits
of the four Insulated receptacles
face the same direction as illustrated
below.
Insulated receptacle
(viewed from the wheel installation side)
Terminal of Switch
Terminal
Slit in Terminal
Insulator
Switch
Insulated receptacle
Connecting Insulated Receptacles
with Terminals of Switch
Fix the following lead wires
with this lead wire holder:
*2 Field lead wires (black)
*Lead wire of Soft start circuit (white)
*Lead wire of Soft start circuit (orange or red)
Rib
Be careful not to route
the lead wires of Power
supply cord over this rib.
If Line filter is used,
route two Field lead
wires (black) through it,
and put in this space.
Fix the following lead wires with this lead
wire holder, and put in this space:
*2 Field lead wires (purple, orange)
*2 Connecting lead wires (purple, orange)
from Brush holder
Put Soft start circuit
in this space.
Put Noise suppressor
in this space if used.
Switch
[Correct]
[Wrong]