16
After selecting numerical value, press and hold the function setting key
for more
than half a second (less than 2 seconds). Now, the battery packs setting is confirmed
and the battery type value below will flash
。
④
set the battery type in the same way.
⑤
Exit from the setting interface. Press and hold function setting key
for more than
half a second (less than 2 seconds), exit from the setting interface and return to
main interface.
4.3.5
Load segment setting
(
5
)
①
Enter the setting interface. Press and hold the function setting key
for more
than 2 seconds, then come to setting interface, Press and hold the scroll key
for
more than half a second(less than 2 seconds), select the function setting, choose
battery setting interface, at the moment, the letters “Seg 1” will flash.
②
Enter the load segment setting interface. Press and hold the function setting
key
for more than half a second(less than 2 seconds), then come to setting
interface of load segment, the letters “Seg 1” will stop flashing. The numerical value
below the “Seg 1” will flash. Press and hold the scroll key
for more than half a
second (less than 2 seconds), select the battery voltage, 10.5v
,
11.0v
,
11.5v(default is
10.5v)
。
③
Confirm the power shedding shielding battery voltage setting. After selecting
numerical value, press and hold the function setting key
for more than half a
second (less than 2 seconds). Now, the load shielding battery voltage setting is
confirmed.
④
Exit from the setting interface. Press and hold function setting key
for more than
half a second (less than 2 seconds), exit from the setting interface and return to main
interface.