5.9.  Diode Test   

1.   Insert the black test lead banana plug into the negative 

COM

 jack 

    and the red test lead banana plug into the 

V

 CAP TEMP Hz Ω

 

    positive jack

2.   Turn the function switch to 

Ω   

CAP

. Use the 

MODE

 

    button to select the diode function if necessary (diode symbol will 
    appear on the LCD when in Diode test mode)

3.   Touch the test probe tips to the diode or semiconductor junction 
    under test. Note the meter reading

4.   Reverse the test lead polarity by reversing the red and black leads. 
    Note this reading

5.   The diode or junction can be evaluated as follows:

   

 

If one reading displays a value (typically 0.400V to 0.900V) and 

     

the other reading displays 

OL

, the diode is good.

   

 

If both readings display 

OL

 the device is open.

   

 

If both readings are very small or '0', the device is shorted.

5.10.  THD Measurement (AC mode only)   

Select the “

THD

” indicator then press the 

MODE

 key to enter the 

THD

mode. THD-F=RMS of Harmonics ÷ RMS of fundamental ×100%. 
(harmonics up to the 50th)

5.11.  Individual Harmonic Measurement (AC mode only)  

Select the “    “ indicator then press the mode key to enter the
individual harmonic mode. Select the “Hn “ indicator then press the 
and      key to enter the individual harmonic mode. Hn=

RMS

 of 

Individual Harmonic ÷ RMS of fundamental ×100%.

14

Содержание MT785

Страница 1: ...MT785 1000 A AC DC TRMS POWER CLAMP METER...

Страница 2: ...2...

Страница 3: ...Contents Page no 3...

Страница 4: ...e Remove the battery if meter is to be stored for longer than 60 days 1 3 Warnings Set function switch to the appropriate position before measuring When measuring volts do not switch to current resist...

Страница 5: ...600V DC AC V DC V AC Resistance Capacitance Frequency Diode Test Temperature 2 Description 2 1 Meter Description 1 Current clamp 2 Flash light LED 3 Non contact AC voltage indicator light 4 Flash ligh...

Страница 6: ...ange Mode DC AC Direct Current Alternating Current Low Battery mV or V Milli volts or Volts Voltage Ohms Resistance A Amperes Current F Farad Capacitance Hz Hertz Frequency Percent duty ratio C and F...

Страница 7: ...its AC True RMS Voltage 6 000V 60 00V 600 0V 1000V 1mV 10mV 100mV 1V 1 2 of rdg 5digits 1 2 of rdg 5digits 1 5 of rdg 5digits 3 of rdg 8digits Maximum Input 1000V DC AC Response 50 Hz to 400Hz Not sin...

Страница 8: ...20Hz 10kHz 0 1Hz 0 5 of reading 3digits Frequency Function Range Resolution Accuracy AC A AC V 99 9 0 1 3 of reading 10digits Total Harmonic Distortion Harmonic distortion measurement Function Range R...

Страница 9: ...igits 1 5 of reading 3digits 2 0 of reading 5digits 3 of reading 8digits Function Range Resolution Accuracy Capacitance Capacitance 9 999uF 99 99uF 999 9uF 9999uF 1nF 10nF 0 1uF 1uF 3 of reading 5digi...

Страница 10: ...eadings per second nominal PEAK Captures peaks 1ms INRUSH 100MS Temperature sensor Type K thermocouple Input Impedance 10M VDC and VAC AC response True RMS A AC and V AC Operating Temperature 5 C to 4...

Страница 11: ...e trigger to open jaw Fully enclose only one conductor For optimum results center the conductor in the jaw 5 The clamp meter LCD will display the reading NOTE Press ZERO button to test DC Current Meas...

Страница 12: ...rt under test If OL appears in the display remove and discharge the component 4 Read the capacitance value in the display 5 The display will indicate the proper decimal point and value Note For very l...

Страница 13: ...urements 1 Set the function switch to the TEMP position 2 Insert the Temperature Probe into the negative COM and the V CAP TEMP Hz positive jacks observing polarity G 3 Touch the Temperature Probe hea...

Страница 14: ...ode or junction can be evaluated as follows If one reading displays a value typically 0 400V to 0 900V and the other reading displays OL the diode is good If both readings display OL the device is ope...

Страница 15: ...e Mode key to choose the W PF mode Note The meter offer AC power measurement mode only 1 Single Phase Power Measurement Active power sign No sign Indicates the power flows from the power source to the...

Страница 16: ...ected perform the following 1 Momentarily press the RANGE button The AUTO indicator will no longer be shown on the LCD display 2 Momentarily press the RANGE button to step through the available ranges...

Страница 17: ...ing the rotary switch MAX MIN Press the Flash light button to turn the flash light on Press again to turn the flash light off Flash Light Button The LCD is equipped with backlighting for easier viewin...

Страница 18: ...do not use abrasives or solvents If the meter is not to be used for 60 days or more remove the battery and store it separately Battery Replacement 1 Remove the Phillips head screw that secures the rea...

Страница 19: ...19...

Страница 20: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Отзывы: