29
4.12. Diode Test
1. Set the rotary switch to the
Ω
CAP Position.
2. Insert the black test lead banana into the
COM
Input Jack; Insert the
red test lead banana into the
Positive
Input Jack.
3. Use the
MODE
Button to select the diode function if necessary (Diode
symbol will appear on the LCD when in Diode test mode).
4. Touch the test probe tips to the diode or semiconductor junction under
test, note the meter reading.
5. Reverse the test lead polarity by reversing the red and black leads, note
this reading.
6. The diode or junction can be evaluated as follows:
• If one reading displays a value (typically 0.400V to 0.900V) and the
other reading displays “
OL
”, the diode is good.
• If both readings display “
OL
” the device is open.
• If both readings are very small or “
0
”, the device is shorted.
Содержание MT785
Страница 1: ...MT785 1500V DC H W ANALYSIS CLAMP METER WITH DATA LOGGER MOBILE APP INSTRUCTION MANUAL...
Страница 2: ...2...