This symbol adjacent to another symbol, terminal or operating 

device indicates that the operator must refer to an explanation 
in the Operating Instructions to avoid personal injury or 
damage to the meter.

This WARNING symbol indicates a potentially hazardous 

situation, which if not avoided, could result in death or serious 
injury.

This CAUTION symbol indicates a potentially hazardous 

situation, which if not avoided, may result damage to the 
product.

This symbol advises the user that the terminal(s) so marked 

must not connected to a circuit point at which the voltage with 
respect to earth ground exceeds (in this case) 1000 VAC or 
VDC.

This symbol adjacent to one or more terminals identifies them 

as being associated with ranges that may, in normal use, be 
subjected to particularly hazardous voltages. For maximum 

2. SAFETY
2.1. Safety Information

1. INTRODUCTION

The MT784 is a CAT IV 600V True RMS 1000A AC/DC digital clamp meter 
incorporating an 80 x 80 pixel Thermal Imager with a range from -20°C to 
260°C. This clamp meter has a large 6000 count colour TFT LCD display 
that provides fast sampling times and high accuracy measurements. The 
meter has been designed to measure 1500V DC purposely for the Solar 
industry, 1000V AC, K-Type temperature, frequency, capacitance, AC+DC 
Voltage and resistance measurements, plus the Low Z range function has a 
low pass filter to eliminate errors caused by "Ghost" voltages. The 100ms 
Inrush current detects starting up currents of electric motors, input surge 
current, or switch-on surge currents, this is the maximum instantaneous 
input current drawn by an electrical device when first turned on.

The meter has a built-in record and store function and displays trend 
capture, using the Bluetooth function the meter wirelessly transmits data to 
the Android or iOS mobile App allowing the user to view, save, organise 
and share recordings. Added features is Non-Contact voltage detection, 
Peak Hold, Min/Max and Average, Data hold function and a built-in 
flashlight for dimly lit areas. The double injection moulded housing is IP65 
waterproof.

1. INTRODUCTION

The MT784 is a CAT IV 600V True RMS 1000A AC/DC digital clamp meter
incorporating an 80 x 80 pixel Thermal Imager with a range from -20°C to
260°C. This clamp meter has a large 6000 count colour TFT LCD display
that provides fast sampling times and high accuracy measurements. The
meter has been designed to measure 1500V DC purposely for the Solar
industry, 1000V AC, K-Type temperature, frequency, capacitance, AC+DC
Voltage and resistance measurements, plus the Low Z range function has a
low pass filter to eliminate errors caused by "Ghost" voltages. The 100ms
Inrush current detects starting up currents of electric motors, input surge
current, or switch-on surge currents, this is the maximum instantaneous
input current drawn by an electrical device when first turned on.
The meter has a built-in record and store function and displays trend
capture, using the Bluetooth function the meter wirelessly transmits data
to the Android or iOS mobile App allowing the user to view, save, organise
and share recordings. Added features is Non-Contact voltage detection,
Peak Hold, Min/Max and Average, Data hold function and a built-in
flashlight for dimly lit areas. The double injection moulded housing is IP65
waterproof.

2. KEY FEATURES

•  6000 Count 2.4” TFT Color LCD Display
•  Built-in Thermal Imager with Max,Min and Center Crosshair Targeting
•  50Hz fast Thermal Image Frame Rate
•  DC Current
•  AC, AC+DC TRMS Current
•  DC Voltage
•  AC, AC+DC TRMS Voltage
•  Resistance and Continuity Test
•  Diode Test
•  Capacity
•  Frequency
•  Duty Cycle
•  Temperature with K-type Probe
•  Flexible Coils Current

Содержание MT784

Страница 1: ...MT784 1500V DC THERMAL CLAMP METER WITH DATA LOGGER MOBILE APP INSTRUCTION MANUAL...

Страница 2: ...2...

Страница 3: ...tage Measurement 11 4 3 AC Voltage Measurement 12 4 4 Frequency Measurement 13 4 5 LoZ AC Voltage Measurement 14 4 6 Resistance Measurement 15 4 7 Continuity Check 16 4 8 Diode Test 17 4 9 Capacitance...

Страница 4: ...11 Factory Set 34 6 3 Record Measurements 35 7 Image Browser 37 7 1 How to Capture a Screen 38 8 Specifications 39 8 1 General Specifications 39 8 2 Thermal Imager Specifications 40 8 3 TRMS Clamp Met...

Страница 5: ...rporating an 80 x 80 pixel Thermal Imager with a range from 20 C to 260 C This clamp meter has a large 6000 count colour TFT LCD display that provides fast sampling times and high accuracy measurement...

Страница 6: ...age Category III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations Note Examples include switches in the fixed installation and some equipment for industrial use with permanent...

Страница 7: ...o replace the fuse or batteries Never operate the meter unless the back cover and the battery and fuse covers are in place and fastened securely If the equipment is used in a manner not specified by t...

Страница 8: ...sent reading in the display and allows the display to be saved MODE VFD Press the MODE key to switch the functions RANGE Press the RANGE key to manual range IR Press the IR key to switch DMM Mode and...

Страница 9: ...otary switch to one of the icons around its perimeter For each function the Meter presents a standard display for that function range measurement units and modifiers Button choices made in one functio...

Страница 10: ...banana plug into the negative COM jack 3 Insert the red test lead banana plug into the Positive jack 4 Press the MODE key to switch the VDC Voltage functions 5 Read the voltage in the display CAUTION...

Страница 11: ...egative COM jack 3 Insert the red test lead banana plug into the Positive jack 4 Press the MODE key to switch the V AC DC Voltage functions 5 Read the AC DC voltage on the display CAUTION Do not measu...

Страница 12: ...not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets As a result the reading may show 0 volts when the outlet actu...

Страница 13: ...e Hz Position 2 Insert the black test lead banana plug into the negative COM jack 3 Insert the red test lead banana plug into the Positive jack 4 Read the Frequency in the display 5 Press the MODE key...

Страница 14: ...ps may not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets As a result the reading may show 0 volts when the outl...

Страница 15: ...into the negative COM jack 3 Insert the red test lead banana plug into the Positive jack 4 Read the resistance on the display WARNING To avoid electric shock disconnect power to the unit under test a...

Страница 16: ...e jack 4 Press the MODE key to switch the continuity functions 5 If the resistance is less than approximately 50 the audible signal will sound 6 If the circuit is open the display will indicate OL WAR...

Страница 17: ...gative COM jack 3 Insert the red test lead banana plug into the Positive jack 4 Press the MODE key to switch the Diode functions Forward voltage will typically indicate 0 400 to 3 000V Reverse voltage...

Страница 18: ...t the red test lead banana plug into the Positive jack 4 Press the MODE key to switch the Capacitance functions 5 Read the Capacitance value on the Display WARNING To avoid electric shock disconnect p...

Страница 19: ...et the function switch to the Temp C F Position 2 Insert the Temperature Probe into the input jacks making sure to observe the correct polarity 3 Read the Temperature on the display 4 Press the MODE k...

Страница 20: ...negative COM jack 3 Insert the red test lead banana plug into the Positive jack 4 Read the current in the display 5 Press the MODE key to switch the AC and AC DC Current 6 Press the RANGE key to switc...

Страница 21: ...urrent measurements up to 600A DC set the function switch to the 600A Position 3 For current measurements up to 1000A DC set the function switch to the 1000A Position 4 Press the MODE button to indica...

Страница 22: ...function switch to the 60A Position 2 For current measurements up to 600A AC set the function switch to the 600A Position 3 For current measurements up to 1000A AC set the function switch to the 1000...

Страница 23: ...e function switch to the 60A or 600A 1000A Position 2 Press the INRUSH Button Enter key 2 second to indicate on the display Then measurement display 3 Clamp the cable to be motor 4 Start the motor 5 R...

Страница 24: ...he HOLD key to release the freeze mode 4 17 Capturing Minimum and Maximum Values The MAX MIN Record mode captures minimum and maximum input values When the input goes below the recorded minimum value...

Страница 25: ...REL key can be used as the ZERO function of DC current as well as relative value measurement of other functions Hold down the HOLD REL key to enter REL function Hold down this key to quit REL 4 19 Ca...

Страница 26: ...Unit of the meter 16 Lowest reading measured in the current frame 17 The Thermal scale shows the range colour for thermal images The lighter the colour the warmer the temperature the darker the colou...

Страница 27: ...ith measure data into SD card the saved bitmap later can be analysed by the PC software or smart phone APPs 8 The thermal imager s FOV Field of view is 21 by 21 degrees 9 FOV is the largest area that...

Страница 28: ...ues on IR Clamp Meter Mode 1 To activate the maximum in mode press the key to display the max value 2 If the Meter is already in the maximum function then press the key to display the min value then p...

Страница 29: ...SETTINGS MENU 6 1 Using Settings Menus Press MENU button to open the Settings Menus as show below Press UP DOWN button to select the menu item or change the value of the current focus item Press RIGH...

Страница 30: ...ns are available Hot Point and Cold Point Press RIGHT MENU button to set or select item on or off Hot Point This option enables the thermal imager to automatically detect the highest temperature point...

Страница 31: ...he RIGHT MENU button to set beep on or off Bluetooth Use the RIGHT MENU button to set bluetooth power on or off Laser Use the RIGHT MENU button to set laser pointer on or off Brightness Press the RIGH...

Страница 32: ...icon on the Home interface bluetooth device name will appear The detail information about Thermview please refer to Thermview APP help file Thermview for Android Please search in Google Play with keyw...

Страница 33: ...o Press the RIGHT MENU Button to enter photo menu Two options are available Photo Review and Delete Photo Photo Review Press the RIGHT MENU Button to enter image browser function and exit settings men...

Страница 34: ...menu This menu contains the software version hardware version and thermal imager version 6 2 11 Factory Set When selecting the Factory Set option after pressing the RIGHT MENU button a dialog box will...

Страница 35: ...press the Button or key to select record Item Press the button Enter Record Menu In Record Menu press the Button or key to select Sample Interval Item or Duration Item Press the Button Enter Record se...

Страница 36: ...e Button to stop record and Press the Button Save In Record Menu Press the Button or key to select Review Item Press the Button Enter View Record measurement Press the Button MODE key to Trend record...

Страница 37: ...oints X3 for at least 40 measuring points and so on for maximum 6 zooming operations In Record Menu press the button or key to select Delete all Recordings Item Press the button Enter Delete Box and s...

Страница 38: ...When in clamp meter mode or thermal imaging clamp meter mode use the HOLD button to enter hold mode as shown below Then press the UP Button to capture screen After saving to TF card completely Clamp M...

Страница 39: ...12VDC 2A Low Battery Indication Symbol on the Display Auto Power Off After 15 to 60 minutes idling May be disabled Display Conversion TRMS Characteristics Colour TFT 6000 Dots with Bargraph Sampling...

Страница 40: ...ct Temperature Range 20 to 260 C 4 to 500 F Accuracy 3 C 5 4 F or 3 of reading Environment temperature 10 35 C object temperature 0 C Range Function Accuracy Calculated as reading num digits resolutio...

Страница 41: ...ts 300 0V 0 1V Range Resolution 8 3 3 LowZ AC TRMS Voltage Accuracy Input impedance 300K Protection against overcharge 1000VDC ACrms Accuracy specified from 10 to 100 of the measuring range sine wave...

Страница 42: ...for reference only 30 00A 0 01A 300 0A 0 1A 50Hz 400Hz 3 0 5 digits 3000A 1A Range Resolution 8 3 8 Flexible Coil Current Accuracy Protection against overcharge 1000ADC ACrms Accuracy specified from 1...

Страница 43: ...F 0 1nF 6 000 F 0 001 F 3 0 8 digits 60 00 F 0 01 F 600 0 F 0 1 F 6000 F 1 F 3 5 20 digits 60 00mF 0 01mF Unspecific 100 0mF 0 1mF Range Resolution 8 3 12 Capacitance Accuracy Protection against overc...

Страница 44: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Отзывы: