Overrange Indication  

"OL" is displayed 

Measurements Rate  

2 per second, nominal 

Input Impedance  

≥10MΩ (VDC and VAC) 

Display  

6000 counts LCD 

AC Current  

50-60Hz (AAC) 

AC Voltage bandwidth   50-1000Hz (VAC) 
Bluetooth Connection 

Connection through mobile device

Operating Temperature   5 to 40°C (41 to 104°F)
Storage Temperature  

-20 to 60°C (-4 to 140°F) 

Operating Humidity  

Max 80% up to 31°C (87°F) decreasing linearly 

to 50% at 40°C (104°F) 

Storage Humidity  

<80% 

Operating Altitude  

2000 meters (7000ft.) maximum. 

Over voltage  

Category III 1000V, Category IV 600V. 

Battery  

3x "AAA" 1.5V Battery 

Auto OFF 

approx. 15 minutes 

Safety  

For indoor use and in accordance with Over 

voltage Category II, Pollution Degree 2. 
Category II includes local level, appliance, 
portable equipment, etc., with transient over 

 

 

voltages less than Over voltage Cat. III  

4.11. General Specifications (continued)

5.1. AC/DC Current Measurements 

1.  Set the Function switch to the 

600A AC/DC, 

60A AC/DC

 range. 

2.  Press MODE to switch the AC/DC measurement.  
3.  If the range of the measured is not known, 

select the higher range first then move to the 
lower range if necessary. 

4. Press the trigger to open jaw. Fully enclose one 

conductor to be measured. The clamp meter 
LCD will display the reading. 

NOTES: 

Read and understand all Warning and Caution statements in 

this operation manual prior to using this meter. Set the function select 
switch to the OFF position when the meter is not in use. 

5. OPERATION

 

WARNING:

 Ensure that the test leads are disconnected from the meter 

before making current clamp measurements. 

Содержание MT767

Страница 1: ...MT767 600A AC DC CLAMP METER WITH IR THERMOMETER INSTRUCTION MANUAL...

Страница 2: ...2...

Страница 3: ...4 9 Temp type K 7 4 10 IR Temp D S 4 1 7 4 10 General Specifications 7 5 Operation 8 5 1 AC Current Measurements 8 5 2 AC DC Voltage Measurement 9 5 3 Resistance Measurements 9 5 4 Diode Continuity a...

Страница 4: ...his meter can cause damage shock injury or death Read and understand this user manual before operating the meter Always remove the test leads before replacing the battery Inspect the condition of the...

Страница 5: ...o 5999 measurement reading with 61 segment Analogue Bargraph 4 Auto Range mode 5 Diode test mode 6 Audible Continuity 7 Data Hold mode 9 Units of measure list 10 Frequency duty cycle mode AC DC 8 8 8...

Страница 6: ...ts 600 0 1 5 6 digits 6 000K 60 00K 2 0 5 digits 600 0K 6 000M 2 8 10 digits 60 00M 2 8 10 digits Range Resolution 4 5 Resistance Accuracy of reading digits 999 9nF 9 999 F 4 reading 6 digits 99 99 F...

Страница 7: ...or AC current Diode Test Test current of 0 3mA typical Open circuit voltage 3 2V DC typical Continuity Check Threshold 50 Test current 0 5mA Low Battery Indication is displayed Range Basic Functions 4...

Страница 8: ...ion Degree 2 Category II includes local level appliance portable equipment etc with transient over voltages less than Over voltage Cat III 4 11 General Specifications continued 5 1 AC DC Current Measu...

Страница 9: ...into the negative COM jack and the red test lead banana plug into the positive diode jack 2 Set the function switch to the position 3 Press the MODE button until appears in the display 4 Touch the te...

Страница 10: ...roper decimal point and value WARNING To avoid electric shock disconnect both test probes from any source of voltage before making a temperature measurement WARNING To avoid electric shock be sure the...

Страница 11: ...Button In the AC current measurement mode place a single power cord of the motor in the center of the clamp and press the inrush Bluetooth key to display When the power is turned on the surge current...

Страница 12: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Отзывы: