background image

                                                                                              

 

 

13 

Gel Observation (with MBE-300) 

1. 

Before running gel electrophoresis, remove the foot stands of MBE-300 

and slide MBE-300 under the electrophoresis tank.   

2. 

Place amber filter lid onto the cover of the electrophoresis rank and 

connect the fan cable in case condensation forms under the cover and 

affects the observation. 

Caution

: The fan is NOT water-proof, please be careful not to spill liquid 

onto the fan. Otherwise the fan may malfunction.   

 

3. 

Switch MBE-300 on whenever users would like to observe the gel. 

4. 

For capturing images, it is recommended to remove the cover of MJ-105A 
and place amber filter lid onto the electrophoresis tank. 

 
 
 
 
 
 
 
 

            

 

Magnetic foot stand 

 
 

Note:

 The above picture, gel preparation and gel running instruction serves only as 

suggestion. Please do the experiment base on user’s need. 

 

 

 

 

DOMINIQUE 

DUTSCHER SAS

Содержание MJ-105A

Страница 1: ...Mini Horizontal Electrophoresis System Instruction Manual Catalog No MJ 105A MT 108 www majorsci com service majorsci com Version 10E Date 2018 11 29 D O M I N I Q U E D U T S C H E R S A S...

Страница 2: ...83 mm Tray 2x 50 x 83 mm Tray 1x Double Side Comb 6 teeth x 2 12 teeth Prep 1 Marker 2 Prep2 Marker 2 23 teeth 1x Double Side Comb 8 teeth x 2 17 teeth 12 teeth x 2 25 teeth 1x Black Red Power Cord 1...

Страница 3: ...ection 2 Technical Specifications 8 Section 3 Installation Instructions 9 Section 4 Operation Instructions 10 4 1 Controls and Features 10 4 2 Start the operation 11 Section 5 Maintenance 15 Section 6...

Страница 4: ...is strongly recommended for the user to read the following points carefully before operating this equipment 1 Read and follow the manual instructions carefully 2 Do not alter the equipment Failure to...

Страница 5: ...Environmental Conditions Ensure that the instrument is installed and operated strictly under the following conditions 1 Indoor use only 2 95 RH 3 75 kPa 106 kPa 4 Altitude must not exceed 2000 meters...

Страница 6: ...rs should check with the manufacturer s instruction to see if the proposed method will damage the equipment Equipment Operation Follow the guidelines below to ensure safe operation of the unit 1 NEVER...

Страница 7: ...are convenient to cast and samples are easy to load The moulded design prevents cracks and leakages and the sturdy PC provides a 130 C temperature capacity The safety interlock cover is designed to pr...

Страница 8: ...er stand Cast 6 pcs of agarose gel in one time MT 108 additional features Longer tray allows running of bigger fragments to attain higher resolution Two tray options available Contain 1 set of gel mak...

Страница 9: ...C Gel Tray Dimension W x L 52 x 60 mm 50 x 83 mm 107 x 60 mm 105 x 83 mm Maximum Gel Thickness 10mm Maximum sample 25 samples Buffer Volume Approx 200 ml Approx 400 ml Lid Safety and ventilation desi...

Страница 10: ...rection So make sure that the comb grooves closest to the black electrode are marked 2 Remove the tray 3 Note the position of the cover on the unit This indicates the correct polarity and the correct...

Страница 11: ...Features MJ 105A MT 108 Tank Lid Black Red Power Cord 50 x 83 mm Tray Analytical Comb Gel Maker Stand 105 x 83 mm Tray 52 x 60 mm Tray Analytical comb 107 x 60 mm Tray Tank Lid Black Red Power Cord Ge...

Страница 12: ...ranslucent crystals These will interfere with sample migration if not completely dissolved Note The gel is suggested to be cooled to between 50 C and 60 C degrees before pouring 3 Install the Gel Tray...

Страница 13: ...he electrophoresis tank to 5mm above the gel 4 Load the samples into the wells and then attach the safety ventilation cover Finally connect the power cords to the power supply unit 5 Turn on the power...

Страница 14: ...on Caution The fan is NOT water proof please be careful not to spill liquid onto the fan Otherwise the fan may malfunction 3 Switch MBE 300 on whenever users would like to observe the gel 4 For captur...

Страница 15: ...resis place the DNA gel onto the center of MBE 300 to capture clearer images 2 Switch MBE 300 on and place MBE HOOD to cover MBE 300 and a DNA gel 3 Observe and capture images of a DNA gel through the...

Страница 16: ...rinse with distilled water Air dry before use Some cleaning agents are not supposed to come in contact with the electrophoresis systems such as Acetone Phenol Chloroform Alcohol and Alkalis If you ha...

Страница 17: ...synthetic paper hood are included MJA MBEP Package of MJ 105A and MBE 300 amber filter lid with fan synthetic paper hood are included Dual Electrophoresis Packages MJAA Mini300 Package of 2 x MJ 105A...

Страница 18: ...alytical Comb 8 teeth x 2 for mini gel 17 teeth for midi gel 12 teeth x 2 for mini gel 25 teeth for midi gel MT C03 Analytical Comb 6 teeth x 2 for mini gel 12 teeth for midi gel Prep 1 Marker 2 Prep...

Страница 19: ...Electrophoresis Packages For MT 108 Single Electrophoresis Packages Dual Electrophoresis Packages MT Mini300 MJAT Mini300 MJAA Mini300 MJAT Mini300 MTT Mini300 MT 100P D O M I N I Q U E D U T S C H E...

Страница 20: ...r the warranty is limited to the receipt of reasonable proof by the customer that the defect is embraced within the terms of the warranty All claims made under this warranty must be presented to Major...

Отзывы: