Warning 

 

Major Science Mini Horizontal Gel Electrophoresis System series has been 

tested and found to comply with the limits for the CE regulation. Also, Mini 

Horizontal Gel Electrophoresis System series is RoHS compliant to deliver 

confident product which meets the environmental directive. These limits are 

designed to provide reasonable protection against harmful interference when 

the instrument series is operated in a commercial environment. This 

instrument series used together with power supply unit generates, uses, and 

can radiate radio frequency energy, and if not installed and used in accordance 

with the instruction manual, may cause harmful interference to radio 

communications. Operation of this instrument series in a residential area is 

likely to cause harmful interference in which case the user will be required to 

correct the interference at their expense. Changes or modifications not 

expressly approved by the party responsible for compliance could void the 
user’s authority to operate the equipment. It is strongly recommended for the 

user to read the following points carefully before operating this equipment. 

 

1.  Read and follow the manual instructions carefully. 

2.  Do not alter the equipment. Failure to follow these directions could result 

in personal and/or laboratory hazards, as well as invalidate equipment 

warranty. 

3.  Use a properly grounded electrical outlet with correct voltage and current 

handling capacity. 

4.  Disconnect from power supply before maintenance and servicing. Refer 

servicing to qualified personnel. 

5.  Never use this instrument series without having the safety cover correctly 

in position. 

6.  Do not use the unit if there is any sign of damage to the external tank or 

cover. Replace damaged parts. 

7.  Do not use in the presence of flammable or combustible material; fire or 

explosion may result. This device contains components which may ignite 

such materials. 

8.  Refer maintenance and servicing to qualified personnel. 

9.  Ensure that the system is connected to electrical service according to 

local and national electrical codes. Failure to make a proper connection 

may create fire or shock hazard. 

10.  Use appropriate materials and operate correctly to avoid possible hazards 

DOMINIQUE 

DUTSCHER 

SAS

Содержание MJ-105-S

Страница 1: ...Mini Horizontal Electrophoresis System Instruction Manual Catalog No MJ 105 S MJ 105 R MT 108 Version 01E Date 2014 3 20 D O M I N I Q U E D U T S C H E R S A S...

Страница 2: ...i Electrophoresis Tank Cover 1x Gel Maker Stand 1x 105 x 83 mm Tray 2x 50 x 83 mm Tray 1x Double Side Comb 6 teeth x 2 12 teeth Prep 1 Marker 2 Prep2 Marker 2 23 teeth 1x Double Side Comb 8 teeth x 2...

Страница 3: ...scription 6 Section 2 Technical Specifications 8 Section 3 Installation Instructions 9 Section 4 Operation Instructions 10 4 1 Controls and Features 10 4 2 Start the operation 10 Section 5 Maintenance...

Страница 4: ...is strongly recommended for the user to read the following points carefully before operating this equipment 1 Read and follow the manual instructions carefully 2 Do not alter the equipment Failure to...

Страница 5: ...Environmental Conditions Ensure that the instrument is installed and operated strictly under the following conditions 1 Indoor use only 2 95 RH 3 75 kPa 106 kPa 4 Altitude must not exceed 2000 meters...

Страница 6: ...rs should check with the manufacturer s instruction to see if the proposed method will damage the equipment Equipment Operation Follow the guidelines below to ensure safe operation of the unit 1 NEVER...

Страница 7: ...or very fast and clear separation of DNA or RNA restriction fragments This series is offered as a complete system including all the necessary accessories for the user to cast run and perform electroph...

Страница 8: ...of agarose gel in one time for MT 108 High temperature capability 130 C Easy sample loading Great indications for gel making and running No tapes clamps or springs needed D O M I N I Q U E D U T S C...

Страница 9: ...PC Polycarbonate Construction Material Transparent Lid AS Acrylonitrile Styrene Copolymer Temperature Capacity 130 C Unit Dimension Tank and Transparent Lid 140 x 140 x 53 mm W x L x H Gel Dimension T...

Страница 10: ...Black well visualization strip Migration distance index line Rapid Casting Gel Use gel maker stand Operating Temperature 4 40 C Weight 0 7 kg Section 3 Installation Instructions 1 Seat the tray in th...

Страница 11: ...esired ratio 2 Dissolve the agarose powder by heating the agarose either on a magnetic hot plate with a stirring bar or in a microwave oven If using the microwave method the microwave should be set at...

Страница 12: ...for a large tray pour 12 to 15 ml for a small tray The tray contains the agarose level for reference Note Pour the agarose carefully so as not to generate bubbles Any bubble that surfaces could be smo...

Страница 13: ...ly connect the power cords to the power supply unit 5 Turn on the power supply unit and adjust to the desired electrophoresis running conditions 6 When the electrophoresis running is complete turn the...

Страница 14: ...tes After that rinse with distilled water Air dry before use Some cleaning agents are not supposed to come in contact with the electrophoresis systems such as Acetone Phenol Chloroform Alcohol and Alk...

Страница 15: ...phoresis Packages MJSS Mini300 Package of 2 x MJ 105 S and Mini 300 MJRR Mini300 Package of 2 x MJ 105 R and Mini 300 MTT Mini300 Package of 2 x MT 108 and Mini 300 MJSR Mini300 Package of MJ 105 S MJ...

Страница 16: ...01 MT CASTER C contains 1 x MT G01 1 x MT T01 2 x MT 02 1 x MT C03 and 1 x MJ C01 Single Electrophoresis Packages MJS Mini300 MJR Mini300 MT Mini300 Dual Electrophoresis Packages MJSS Mini300 MJRR Min...

Страница 17: ...the warranty is limited to the receipt of reasonable proof by the customer that the defect is embraced within the terms of the warranty All claims made under this warranty must be presented to Major S...

Страница 18: ...17 MEMO D O M I N I Q U E D U T S C H E R S A S...

Страница 19: ...18 MEMO D O M I N I Q U E D U T S C H E R S A S...

Страница 20: ...19 MEMO D O M I N I Q U E D U T S C H E R S A S...

Отзывы: