Warning 

Major Science Genius Dry Bath Incubator has been tested and found to 
comply with safety limits for the CE regulation. Also, Genius Dry Bath 
Incubator is RoHS compliant to deliver confident product which meets the 
environmental directive. These limits are designed to provide reasonable 
protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy, and if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications. 
Operation of this equipment in a residential area is likely to cause harmful 
interference in which case the user will be required to correct the interference 
at their expense. Changes or modifications not expressly approved by the 
party responsible for compliance could void the user’s authority to operate the 
equipment. It is strongly recommended for the user to read the following points 
carefully before operating this equipment. 
 
1. Read and follow carefully the manual instructions. 
2. Do not alter the equipment. Failure to follow these directions could result in 
personal and/ or laboratory hazards, as well as invalidate equipment warranty. 
3. Use a properly grounded electrical outlet with correct voltage and current 
handing capacity. 
4. Disconnect from power supply before maintenance and servicing. Refer 
servicing to qualified personnel.   
5. Never use this instrument series without having the safety cover correctly in 
position. 
6. Do not use the unit if there is any sign of damage to the external tank or 
cover. Replace damaged parts. 
7. Do not use in the presence of flammable or combustible material; fire or 
explosion may result. This device contains components which may ignite such 
materials. 
8. Refer maintenance and servicing to qualified personnel. 
9. Ensure that the system is connected to electrical service according to local 
and national electrical codes. Failure to properly connection may create fire or 
shock hazard. 
10. Use appropriate materials and operate correctly to avoid possible hazards 
of explosion, implosion or release of toxic or flammable gases arising from 
overheated materials. 

Содержание MD-01N-110

Страница 1: ...Genius Dry Bath Incubator Instruction Manual Catalog No MD 01N 110 220 MD 02N 110 220 MD 01N T 110 220 MD 02N T 110 220 www majorsci com service majorsci com Version 02D Revision on 2015 08 12...

Страница 2: ...hasing MD 01N T 110 220 or MD 02N T 110 220 1 Single Block Genius Dry Bath Incubator or 1 Dual Block Genius Dry Bath Incubator 1 External Temperature Probe 1 Power Cord 1 Genius Dry Bath Incubator Ins...

Страница 3: ...s 10 Section 4 Installation Instructions 11 Section 5 Operation Instructions 12 Temperature Calibration 13 Section 6 Function Control Software Instructions 15 6 1 Installation Instruction 15 6 2 Opera...

Страница 4: ...fore operating this equipment 1 Read and follow carefully the manual instructions 2 Do not alter the equipment Failure to follow these directions could result in personal and or laboratory hazards as...

Страница 5: ...he electrical supply check to see if the supply voltage is within the range stated at the rating label and see to it that the device be seated firmly Place the unit in a safe and dry location it must...

Страница 6: ...ce behind the instrument and at least 5 cm of space on each side 4 Use high level of precautions against the damages on the unit 5 Do not operate the unit out of environmental conditions addressed abo...

Страница 7: ...st Consult the manual to avoid possible personal injury or instrument damage ATTENTION Hot surface Indicates disposal instruction DO NOT throw this unit into a municipal trash bin when this unit has r...

Страница 8: ...al results from one experiment to another Genius Dry Bath Incubators are also space compact instruments with competitive pricing offerings It is a user friendly unit that comes with great value More i...

Страница 9: ...or select timer mode 5 TIMER This LED light indicates running Timer Mode 6 Set Temp This LED light indicates temperature is on setting value 7 Heating This LED light indicates temperature is increasin...

Страница 10: ...t stability Temperature may be set in 0 1 C increments from 5 C above ambient to 150 C An optional temperature probe is available for placing directly in samples A timer equipped within the unit may b...

Страница 11: ...e proof for heating chamber Over Temperature protection SSR failure detection Operating Temperature Ambient to 40 C Heating Chamber Material Molded aluminum alloy chamber Chamber Dimension 104 5 x 79...

Страница 12: ...Dry Bath Incubator is actually a pre installed instrument As long as it is placed on a sturdy and level surface in a safe dry place and is inserted with one or two heating aluminum block s or simply w...

Страница 13: ...r 4 Turn the AC power ON 5 Run temperature calibration procedure when using the instrument for the first time see page 12 6 Press or Key to adjust to the desired temperature 7 If setting heating time...

Страница 14: ...1 Insert a 300mm calibrated laboratory thermometer into the thermometer holding port which is on the block or in the middle of chamber when water is filled 2 Switch the main power ON and press Key sim...

Страница 15: ...14 6 The calibrated procedure is finished Please wait for a few more minutes for the microprocessor to automatically adjust displayed temperature value to the same value with thermometer measured...

Страница 16: ...ete the installation 6 2 Operation Instruction 1 Start MD 01 software program The screen below will be displayed There are two main sections in the software View Chart and View History 2 View Chart Se...

Страница 17: ...rded REC period ON OFF To start or stop recording Enlarge the record table Move the record table 3 View History Section Serial Port No Communication port selections between computer and Genius Dry Bat...

Страница 18: ...table or not Temp PV ON OFF To show the real time temp value on the table or not CLEAR CHART OFF To clear up the curves in the table Open File ON to view historic record data OFF No historic record d...

Страница 19: ...olution Err1 If the actual temperature is over 5 C than the set temperature value during operation Err1 will be displayed along with alarm and the instrument will shut down automatically Turn off the...

Страница 20: ...th containing a mild soap solution The chamber and blocks are constructed of aluminum alloy and may be cleaned with any of the commercial aluminum cleaners on the market The heating surface contains a...

Страница 21: ...PCR plate for single block unit only MD MP01 D For Microplate Titerplate for dual block unit only MD MP02 D For 96 wells Deep Microplate or PCR Plate for dual block unit only MD B0 2 For 0 2 ml tube...

Страница 22: ...ty is limited to the receipt of reasonable proof by the customer that the defect is embraced within the terms of the warranty All claims made under this warranty must be presented to Major Science wit...

Страница 23: ...22 MEMO...

Страница 24: ...23 MEMO...

Отзывы: