Majestic SC36A Скачать руководство пользователя страница 9

9

SR/SC Series "A" Woodburning Fireplace

7412948

Framing

Framing can be constructed before or after the fireplace 
is set in place, however, most installers build the frame 
before setting the fireplace.
Frame fireplace with 2 x 4 lumber or heavier materials.  
Refer to framing dimensions in Figures 1, 2, 3 or 4  for 
basic fireplace specifications.

NOTE:

  Framing should be positioned to accommodate 

wall covering and fireplace facing material. 

Installing Electrical Wire 

(for Circulator Models)

If a circulating fireplace is to be installed, run the 120 
VAC, 60 Hz wiring to the left side of installation.  Wiring 
must be completed 

before

 the fireplace is secured and 

finish material applied.
Remove the cover plate and electrical knockout on the 
lower left side of the fireplace and set aside. Follow the 
instructions on Page 10 for proper wiring and installation 
of the EB1.
If the fan kit is not being installed with the fireplace, it 
is highly recommended that 120 VAC supply be made 
available since someone may elect to install a blower at 
a later date.

Option For Circulating Models Only — 

EB1 (Receptacle) Hook-Up

• Wiring should be installed by a certified
  electrician.
• Turn off circuit breaker before wiring models.
Once fireplace is secured, complete wiring the fan 
kit. Remove knockout in the center of the back of 
the EB1 and install listed cable clamps. Feed electri-
cal wire through listed cable clamp leaving approxi-
mately six (6) inches of wire exposed through the 
EB1.  Secure listed cable clamp to the wire. 
Attach white wire from power source to one (1) wire 
of receptacle and secure with nut.  Attach black 
wire from power source to the other wire of recep-
tacle and secure with nut. Be sure nuts are secured 
tightly. 
Secure EB1 assembly to inside of electrical box 
coverplate using two screws. Attach cover to face of 
the EB1 while being careful to position excess wire 
completely within the EB1, then attach coverplate to 
fireplace.

Install Fan Kit Assembly

Refer to optional Model FK12 fan kit assembly in-
stallation instructions for field installation.

Chimney Setup

Since you have already preplanned the chimney run, 
you should know exactly how the installation is to be ac-
complished — how much pipe is required, the number 
of elbows, if any, and type of termination to be used.

CAUTION:  

REPORT TO YOUR DEALERS ANY 

PARTS DAMAGED IN SHIPMENT, SPECIFICALLY 
CHECK THE END CONNECTION OF CHIMNEY SEC-
TIONS AND ELBOWS.

NOTE:

 Fireplaces may use CFM Corporation model 

SK8, or Model S (three wall) chimney systems.  The 
SR/SC Series "A" Fireplace will accept the SK8 chim-
ney system as is; but a TWABR adapter collar is 
required when using the Model S (triple wall) chimney 
system. The installation procedure described in this 
manual applies 

only

 to the SK8 system. Either chimney 

system may be used, but 

may not

 be mixed.

FP555

Fig. 10

  Insulating between platform and fireplace.

FP555

BR

11/10/97

Hard Flat 

Surface

Insulation

Platform

Содержание SC36A

Страница 1: ...R36A SR42A SC36A SC42A For use in U S Canada Underwriter s Laboratories Report No MH6018 DO NOT DISCARD THIS MANUAL Retain for future use 948 SR cover 11 18 97 948 SC cover 11 18 97 7412948 12 06 Rev...

Страница 2: ...tion or assembly with a Majes tic Fireplaces replace system notwithstand ing any independent testing laboratory or other third party approval of such component parts or accessory Any such action may p...

Страница 3: ...ss 8 Dia 203mm 3 4 8 7 6 m m FP590 Fig 2 SC36A Series speci cations and framing SC36A Series Woodburning Fireplace Circulating Model 36 914mm 14 372mm 15 391mm 11 279mm 40 1016mm 39 1006mm 3 76mm 5 8...

Страница 4: ...8 Dia 203mm 3 6 9 1 4 m m FP592 Fig 4 SC42A Series speci cations and framing SC42A Series Woodburning Fireplace Circulating Model 42 1067mm 46 1168mm 39 1006mm 5 8 16mm 5 8 1 6 m m 1 2 13mm 1 2 22 57...

Страница 5: ...Collar Pan Flashing Draftstop Batt Insulation cut out around estop Firestop Ceiling Level Nailing Flange Gas Line Access both sides Electrical Access Outside Air Cover Plate Metal Safety Strips 1 2 o...

Страница 6: ...C42A Maximum 90 0 90 0 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbow to a struc...

Страница 7: ...to the peak of the roof is 10 3m or less the top of the chimney must be at least 2 610mm above the peak of the roof but never less than 3 914mm in height above the highest point where it passes throug...

Страница 8: ...A FIREPLACE IN AN INSULATED ENCLOSURE BE SURE ALL RE QUIRED AIR SPACES ARE MAINTAINED Page 14 Fig 20 Installation Chimney Supports The chimney system is supported by the replace for vertical chimney h...

Страница 9: ...wire through listed cable clamp leaving approxi mately six 6 inches of wire exposed through the EB1 Secure listed cable clamp to the wire Attach white wire from power source to one 1 wire of receptac...

Страница 10: ...s though a straight up chimney arrangement is to be used Mea sure your offset dimension from straight up chimney center point on ceiling Ceiling Chimney Hole Possible Obstructions The size of the hole...

Страница 11: ...on top of the replace Install the pipe as pictured in Figure 16 When you get a good lock you will hear the pipe clearly snap together Once sections are snap locked in place it is extremely dif cult t...

Страница 12: ...tion extending up into the hole If the area above the ceiling is an attic position the restop spacer with the ange on the top of the framed hole and the angled portion extending down into the hole Fir...

Страница 13: ...int of the ue system Drive a nail up through roof at the center point This will determine center point on outside of the roof Cut and Frame Roof Hole Size of roof hole varies with the type of chimney...

Страница 14: ...and 12 305mm from top of grille opening for circulating models Do not install a mantel face plate less than 6 159mm from top of replace opening for radiant models and 6 159mm from top of grille openin...

Страница 15: ...38mm 12 305mm Min 1 38mm 6 159mm Min 12 305mm Max 12 305mm Min 1 38mm 6 159mm Min Mantel Clearance Radiant Model No Noncombustible Facing Material Combustible Mantel and Trim Finished Wall Header Stan...

Страница 16: ...ACE HEARTH COMBUSTIBLE FLOOR MINIMUM INSULATION VALUE R 4 MIN FP594 SR SC 11 20 97 FIREBOX OPENING A Min clearance to combustible perpendicular wall B Min clearance to combustible perpendicular wall w...

Страница 17: ...hermal resistance for a given thickness T K thermal conductivity Noncombustible material with a lower R value may be used provided thickness of material is suf ciently greater to maintain an equivalen...

Страница 18: ...ss ap pliance the nishing material used for the mantel must be rated at 250 F or greater BTU input of a gas appliance installed in replace should be rated less than 100 000 BTU Hr Gas pipe installatio...

Страница 19: ...two per replace 20005487 20005631 5 Screen Pulls 5584139 5584139 6a Firebrick Hearth 20005621 20005421 6b Firebrick Rear 20005627 20005462 6c Firebrick Right Side 20005626 20005461 6d Firebrick Left...

Страница 20: ...ge provided by the owner s insurance Glass Door Standard Bi Fold door set Brushed Brass nish 36GDKBBSR SR SC36A 42GDKBBSR SR SC42A Black nish 36GDKBKSR SR SC36A 42GDKBKSR SR SC42A Polished Brass nish...

Страница 21: ...ate chimney through CT100 a chase top Appropriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required Chase Top Housing Low pro le pyrami...

Страница 22: ...ation Shield Used to prevent insulation from coming in AIS SK contact with the chimney system SK8 Chimney Sections Used to build chimney systems exposed above SK818CAN 1 Long roof SK84CAN 4 Long 45 Ch...

Страница 23: ...ranty is extended only to a Fireplace installed in the continental United States the state of Alaska and Cana da only if and so long as the Fireplace is installed according to the installation instruc...

Страница 24: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: