Majestic SC36A Скачать руководство пользователя страница 2

2

SR/SC Series "A" Woodburning Fireplace

7412948

Safety Information

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE.
IMPORTANT: 

Read all instructions and warnings carefully before starting installation.  Failure to 

follow these instructions may result in a possible fire hazard and will void the warranty.

Description

The SR/SC Series "A" fireplaces are solid fuel, wood-
burning premium fireplaces. The SR36A/42A are radiant 
clean-face models and the SC36A/42A are circulating 
models with removable grilles (louvres). Both models are 
fully insulated fireplaces.

Precautions

CFM Corporation fireplaces and component parts have 
been highly tested and will operate safely when installed 
in accordance with instructions provided in this manual. 
Carefully read and understand all instructions 

before

 

beginning installation.
If you notice any damage to fireplace or component 
parts, immediately report damage to your Majestic Fire-
places dealer.
Only use CFM Corporation components or the warranty 
will be voided and a fire hazard may be created.
CFM Corporation warranty will be voided by and CFM 
Corporation  disclaims any responsibility for the following 
actions:

• 

Installation of any damaged fireplace or chim-
ney component;

• 

Modification of fireplace, chimney assembly or 
any component parts thereof; 

(except for chase 

flashings as detailed in Chimney Top installation 
instructions).

• 

Installation other than as instructed by CFM 
Corporation; or

• 

Installation and/or use of any component part 
not manufactured or approved by CFM Corpo-
ration in combination or assembly with a Majes-
tic Fireplaces fireplace system, notwithstand-
ing any independent testing laboratory or other 
third party approval of such component parts 
or accessory.

Any such action may possibly cause a fire hazard.

Consult local building codes to ensure that you are in 
compliance 

before 

installing the fireplace.

Fireplaces must be vented to the out-of-doors.

Do not obstruct or modify air inlets/outlets in any 
manner. 
Do not install combustible materials on any of the 
black fireplace surround.
Burn only solid wood fuel or gas logs.

Do not install a solid fuel burning insert or other 
products not specified for use with this fireplace.

Proposition 65 Warning:

 Fuels used in gas, wood-

burning or oil fired appliances, and the products of 
combustion of such fuels, contain chemicals known to 
the State of California to cause cancer, birth defects 
and other reproductive harm.
California Health & Safety Code Sec. 25249.6

WARNING: Check with your electronics manufac-
turer before installing a television or other electronic 
device above this fireplace.

Drafts

The fireplace should not be located in areas that create 
drafts (ie: frequently opened doors and central heating air 
inlets/outlets) that hamper the normal flow of air into the 
fire.

Gas Logs

If you plan to install a gas log, the gas line should be 
installed 

before

 framing the fireplace. The gas line must 

be installed by a certified gas line installer.

SR36A / SR42A

SC36A / SC42A

Listed

UL127 / ULC-S610 

Standard for Factory Built Fireplaces

Safety Information . . . . . . . . . . . . . . . . . .  2
Specifications and Framing   . . . . . . . . . .  3
Parts Identification  . . . . . . . . . . . . . . . . .  5
Chimney Requirements  . . . . . . . . . . . . .  6
Planning Information . . . . . . . . . . . . . . . .  7
Installation   . . . . . . . . . . . . . . . . . . . . . . .  8
Replacement Parts . . . . . . . . . . . . . . . .  19
Accessories   . . . . . . . . . . . . . . . . . . . . .  20

Table of Contents

Units: 
SC36A FB40C0 

SR36A FB40R0

SC42A GB40C0 

SR42A GB40R0

Содержание SC36A

Страница 1: ...R36A SR42A SC36A SC42A For use in U S Canada Underwriter s Laboratories Report No MH6018 DO NOT DISCARD THIS MANUAL Retain for future use 948 SR cover 11 18 97 948 SC cover 11 18 97 7412948 12 06 Rev...

Страница 2: ...tion or assembly with a Majes tic Fireplaces replace system notwithstand ing any independent testing laboratory or other third party approval of such component parts or accessory Any such action may p...

Страница 3: ...ss 8 Dia 203mm 3 4 8 7 6 m m FP590 Fig 2 SC36A Series speci cations and framing SC36A Series Woodburning Fireplace Circulating Model 36 914mm 14 372mm 15 391mm 11 279mm 40 1016mm 39 1006mm 3 76mm 5 8...

Страница 4: ...8 Dia 203mm 3 6 9 1 4 m m FP592 Fig 4 SC42A Series speci cations and framing SC42A Series Woodburning Fireplace Circulating Model 42 1067mm 46 1168mm 39 1006mm 5 8 16mm 5 8 1 6 m m 1 2 13mm 1 2 22 57...

Страница 5: ...Collar Pan Flashing Draftstop Batt Insulation cut out around estop Firestop Ceiling Level Nailing Flange Gas Line Access both sides Electrical Access Outside Air Cover Plate Metal Safety Strips 1 2 o...

Страница 6: ...C42A Maximum 90 0 90 0 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbow to a struc...

Страница 7: ...to the peak of the roof is 10 3m or less the top of the chimney must be at least 2 610mm above the peak of the roof but never less than 3 914mm in height above the highest point where it passes throug...

Страница 8: ...A FIREPLACE IN AN INSULATED ENCLOSURE BE SURE ALL RE QUIRED AIR SPACES ARE MAINTAINED Page 14 Fig 20 Installation Chimney Supports The chimney system is supported by the replace for vertical chimney h...

Страница 9: ...wire through listed cable clamp leaving approxi mately six 6 inches of wire exposed through the EB1 Secure listed cable clamp to the wire Attach white wire from power source to one 1 wire of receptac...

Страница 10: ...s though a straight up chimney arrangement is to be used Mea sure your offset dimension from straight up chimney center point on ceiling Ceiling Chimney Hole Possible Obstructions The size of the hole...

Страница 11: ...on top of the replace Install the pipe as pictured in Figure 16 When you get a good lock you will hear the pipe clearly snap together Once sections are snap locked in place it is extremely dif cult t...

Страница 12: ...tion extending up into the hole If the area above the ceiling is an attic position the restop spacer with the ange on the top of the framed hole and the angled portion extending down into the hole Fir...

Страница 13: ...int of the ue system Drive a nail up through roof at the center point This will determine center point on outside of the roof Cut and Frame Roof Hole Size of roof hole varies with the type of chimney...

Страница 14: ...and 12 305mm from top of grille opening for circulating models Do not install a mantel face plate less than 6 159mm from top of replace opening for radiant models and 6 159mm from top of grille openin...

Страница 15: ...38mm 12 305mm Min 1 38mm 6 159mm Min 12 305mm Max 12 305mm Min 1 38mm 6 159mm Min Mantel Clearance Radiant Model No Noncombustible Facing Material Combustible Mantel and Trim Finished Wall Header Stan...

Страница 16: ...ACE HEARTH COMBUSTIBLE FLOOR MINIMUM INSULATION VALUE R 4 MIN FP594 SR SC 11 20 97 FIREBOX OPENING A Min clearance to combustible perpendicular wall B Min clearance to combustible perpendicular wall w...

Страница 17: ...hermal resistance for a given thickness T K thermal conductivity Noncombustible material with a lower R value may be used provided thickness of material is suf ciently greater to maintain an equivalen...

Страница 18: ...ss ap pliance the nishing material used for the mantel must be rated at 250 F or greater BTU input of a gas appliance installed in replace should be rated less than 100 000 BTU Hr Gas pipe installatio...

Страница 19: ...two per replace 20005487 20005631 5 Screen Pulls 5584139 5584139 6a Firebrick Hearth 20005621 20005421 6b Firebrick Rear 20005627 20005462 6c Firebrick Right Side 20005626 20005461 6d Firebrick Left...

Страница 20: ...ge provided by the owner s insurance Glass Door Standard Bi Fold door set Brushed Brass nish 36GDKBBSR SR SC36A 42GDKBBSR SR SC42A Black nish 36GDKBKSR SR SC36A 42GDKBKSR SR SC42A Polished Brass nish...

Страница 21: ...ate chimney through CT100 a chase top Appropriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required Chase Top Housing Low pro le pyrami...

Страница 22: ...ation Shield Used to prevent insulation from coming in AIS SK contact with the chimney system SK8 Chimney Sections Used to build chimney systems exposed above SK818CAN 1 Long roof SK84CAN 4 Long 45 Ch...

Страница 23: ...ranty is extended only to a Fireplace installed in the continental United States the state of Alaska and Cana da only if and so long as the Fireplace is installed according to the installation instruc...

Страница 24: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: