DANGER

DANGER

       

-  Wait five (5) minutes to allow possible     

 

          accumulated gas to clear. 

 

       -  Set the IFT-ECM 3-position selector switch to ON  

          or REMOTE position.  Module will beep once and  

          flash a three GREEN LED code on successful 

 

          startup. 

 

       -  If placed in ON position, the appliance will ignite  

          normally if the error condition was corrected. 

 

       -  If placed in REMOTE position, use the paired IFT-   

          RC400, IFT-RC150 or wired wall switch to start  

          the appliance; appliance will ignite normally if the 

          error condition was corrected.

      -  If the IFT-ECM re-enters the lock-out condition 

 

         after these steps, call your dealer for service.

Wi-Fi (Optional) 

If desired, a Wi-Fi module (IFT-WFM) may be added to 

allow the appliance to be run via an app.  Contact your 

dealer to order.

Fan

•    The fan functions are fully integrated into the Intellifire  

Touch system.

•   Fan operation is controlled by the wireless RC400 

remote.

Electric Embers

•   Electric Embers are a standard feature on this model.
•  The intensity of the these lights may be controlled 

through  the  remote  control    included  with  your  fire

-

place.

Appliance ON/OFF:

The Quartz Platinum Series fireplace is supplied with a 

fully functional remote control.  This remote controls the:

•    ON/OFF Functions

•    Flame Height Adjustments

•  Fan Control

•    Thermostat 

•   Electric Ember Bed

•  Cold Climate Feature

Refer to the RC400 Quick Reference Guide included with 

the RC400 for details on operation. 

Содержание QUARTZPLA36IN

Страница 1: ...unless a certified kit is used DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewin...

Страница 2: ...t Approved Minimum De Gaz Acceptable x x in w c Po Col d eau Maximum Pressure Pression xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pre...

Страница 3: ...Specifications 6 C BTU Specifications 6 D High Altitude Installations 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Wall an...

Страница 4: ...ipment from HHT regardless of the installation or occupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances 10 years fr...

Страница 5: ...pply or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components no...

Страница 6: ...u must comply with the National Fuel Gas Code ANSI Z223 1 latest edition in the U S A and the CAN CGA B149 Installation Codes in Canada B Glass Specifications This appliance is equipped with ceramic g...

Страница 7: ...ildren will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To prevent unintended operation when not using your fire p...

Страница 8: ...cording to the installation instructions Non combustible surfaces and mantels do not have a maximum temperature limit however the installation instructions must still be followed for any restrictions...

Страница 9: ...9 Majestic QUARTZPLA36IN QUARTZPLA36IL Owner s Manual 2643 981 Rev B 7 22 G Lighting Instructions IPI...

Страница 10: ...njunction with the IFT RC400 control The Heat Zone Gas Kit draws heat from your fireplace to an adjacent room in your home up to 20 feet away Optional Heat Out Gas Kit The Heat Out Gas heat management...

Страница 11: ...nsert four AA cell batteries Battery polarity must be correct or module damage will occur See Figure 3 3 A complete wiring diagram is included in the Electrical section of the appliance Installation M...

Страница 12: ...result of a system error When switched to the OFF position while the appliance is operating the system will shut down ON Position The appliance will ignite and run continuously at the HI flame settin...

Страница 13: ...hese steps call your dealer for service Wi Fi Optional If desired a Wi Fi module IFT WFM may be added to allow the appliance to be run via an app Contact your dealer to order Fan The fan functions are...

Страница 14: ...nt and Firebox Top Annually Pilot and Burner Ignition and Operation Annually LED Replacement As needed Electrical Service and Repair As needed Glass Cleaning Frequency Seasonally By Homeowner Tools Ne...

Страница 15: ...tions for proper calibration and setup procedure Replace batteries as needed in remote transmitters and battery powered receivers Place remote control out of reach of children If not using your firepl...

Страница 16: ...ld be avoided Remove all foreign objects Verify unobstructed air circulation Pilot and Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves v...

Страница 17: ...Shock Replace damaged wire with type 105 C rated wire Wire must have high temperature insulation LED Replacement Frequency As needed By Qualified Service Technician Tools needed Protective gloves rep...

Страница 18: ...nishing materials and adhesives used around the fireplace These circumstances may require additional curing related to the installation environment Film on the glass This is a normal result of the cur...

Страница 19: ...tween the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature approaches the desired set temperature on the rem...

Страница 20: ...DC adaptor faulty backup batteries if being used depleted IFT ECM slider switch in OFF position Verify IFT ECM slider switch is in ON or REM position Verify AC power available to junction box Verify...

Страница 21: ...n main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes...

Страница 22: ...Zone Gas Kit 6 6 Reference Materials A Accessories WARNING Risk of Fire and Electric Shock Use ONLY Hearth Home Technologies approved optional accessories with this appliance Using non listed accesso...

Страница 23: ...6 Y 1 Rear Left Base Log SRV2414 709 2 Rear Right Base Log SRV2414 710 3 Front Left Base Log SRV2413 703 4 Front Right Base Log SRV2414 711 5 Top Left Log SRV2413 705 6 Middle Left Cross Log SRV2413 7...

Страница 24: ...attery Pack SRV2326 134 Y 17 7 LED Controller 2166 336 Y 17 8 Module RF FCC SRV2326 120 Y 17 9 Module IFT Control SRV2326 130 Y 17 10 Module B Type AC SRV2326 150 Y 17 11 Harness IFT 6 Pin Wiring SRV2...

Страница 25: ...ION COMMENTS PART NUMBER Exhaust Restrictor 530 299 Finishing Template SRVFS 6 Gasket Assembly 2118 080 Contains Burner neck shutter bracket vent seal cap valve plate ember LED and air passage gaskets...

Страница 26: ...____________________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible...

Отзывы: