WARNING! 

DO NOT operate fireplace before reading 

and  understanding  operating  instructions. 

Failure 

to  operate  fireplace  according  to  operating  instructions 

could cause fire or injury.

Young children should be carefully supervised when they 

are in the same room as the appliance.  Toddlers, young 

children and others may be susceptible to accidental 

contact burns.

•  A physical barrier is recommended if there are at risk 

individuals in the house.  

•  To  restrict  access  to  a  fireplace  or  stove,  install  an 

adjustable safety gate to keep toddlers, young children 

and other at risk individuals out of the room and away 

from hot surfaces.

•  Install a switch lock or a wall/remote control with child 

protection lockout feature.

•  Keep remote controls out of reach of children.

A.  Appliance Safety

A barrier designed to reduce the risk of burns from the 

hot viewing glass is provided with this appliance and 

shall be installed for the protection of children and other 

at-risk individuals.  DO NOT operate the appliance with 

the barrier removed.  If the barrier becomes damaged, 

the  barrier  shall  be  replaced  with  the  manufacturer’s 

barrier for this appliance. 

Contact your dealer or Hearth & Home Technologies if the 

barrier is not present or help is needed to properly install one.

•  Never leave children alone near a hot fireplace, whether 

operating or cooling down.

•  Teach children to NEVER touch the fireplace.
•  Consider not using the fireplace when children will be 

present.

Contact your dealer for more information, or visit: www.

hpba.org/Product-Info/Fireplace-Stove-Heater/Glass-

Fronts-Safety.

To prevent unintended operation when not using your fire

-

place for an extended period of time (summer months, 

vacations, trips, etc):
•  Remove batteries from remote controls.
•  Turn off wall controls.
•  Unplug 3 volt adapter plug and remove batteries on IPI 

models. 

Important Safety and Operating Information 

 

Clear Space

WARNING! DO NOT

 place combustible objects in front of 

the fireplace or block fireplace openings.

 

High tempera

-

tures could start a fire. See Figure 3.1.

 Avoid placing candles and other heat-sensitive objects 

on mantel or hearth. Heat could damage these objects.

Figure 3.1  Clear Space Requirement - All Models

CLEAR SPACE

3 FT. IN 

FRONT OF 

FIREPLACE

DANGER

HOT GLASS 

WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN

 TO TOUCH GLASS.

•  Keep children away.

•  CAREFULLY SUPERVISE children in same room 

as fireplace.

•  Alert children and adults to hazards of high 

temperatures.

High temperatures may ignite clothing or other 

flammable materials.

•  Clothing, furniture, draperies, and other flammable 

materials must not be placed on or near the 

appliance.

WARNING:  

This product and the fuels used to 

operate this product (liquid propane or natural gas), 

and the products of combustion of such fuels, can expose 

you to chemicals including benzene, which is known to the 

State of California to cause cancer and reproductive harm.  

For more information go to: www.P65Warnings.ca.gov.

Содержание QUARTZ32IN

Страница 1: ...lumber or gas fitter See appliance installation manual for additional Commonwealth of Massachusetts requirements DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN...

Страница 2: ...0000 0000FT MAX MAX INPUT INPUTBTUH BTUH 00 000 00 000 00 000 00 000 MIN MIN INPUT INPUT BTUH BTUH 00 000 00 000 00 000 00 000 ORIFICE ORIFICE SIZE SIZE XXXXX XXXXX XXXXX XXXXX XXXXXXXX XXXXXXXX Tota...

Страница 3: ...n 6 B Glass Specifications 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV G...

Страница 4: ...s on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an indepe...

Страница 5: ...RRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishe...

Страница 6: ...ANSI Z97 1 and CPSC 16 CFR 1202 Safety Glazing Certification Council SGCC 1595 and 1597 Architectural Testing Inc Reports 02 31919 01 and 02 31917 01 This statement is in compliance with CPSC 16 CFR...

Страница 7: ...own Teach children to NEVER touch the fireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Sto...

Страница 8: ...MBLY NOT SHOWN SECTION 4 B MANTEL HEARTH FAN KIT SECTION 3 J CLEAR SPACE SECTION 3 A CONTROL CAVITY SECTION 3 I MEASUREMENTS FROM TOP EDGE OF THE OPENING 6 in 18 in 24 in 30 in TO CEILING 12 in 127 F...

Страница 9: ...nd from model to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum al...

Страница 10: ...ve been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that...

Страница 11: ...sed or Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will...

Страница 12: ...trolled by the HI LO knob on the gas valve Therefore the flame height is adjustable The HI LO knob is shown in Figure 3 5 It is located in the control cavity of the appliance The HI LO knob may be adj...

Страница 13: ...normal circumstances Multifunctional Wired Wall Switch Control System Locate the wired wall switch control module in control cavity Locate battery operation switch on the side of the module Slide the...

Страница 14: ...The term Intermittent is used because the pilot burner flame is only present when the main burner is operating When the main burner is off the pilot is also off NOTICE Batteries should not be placed i...

Страница 15: ...ace with one hand and secure two top and two bottom glass latches with the other hand Inspect and operate all glass latches to ensure they move freely and no obstructions are present Reinstall decorat...

Страница 16: ...needed in remote transmitters and battery powered receivers Place remote control out of reach of children If not using your fireplace for an extended period of time summer months vacations trips etc t...

Страница 17: ...d Remove all foreign objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves vacuum cleaner whisk br...

Страница 18: ...al to see the pilot flame burn continually In an intermittent pilot ignition system IPI the pilot flame should turn off when appliance is turned off Some optional control systems available with IPI mo...

Страница 19: ...pect pilot assembly for shorted sparker wire or cracked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark A No power or transformer installed incorre...

Страница 20: ...or rect pilot orifice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing r...

Страница 21: ...r fireplace For safety Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children See your dealer if you have questions Install...

Страница 22: ...e Log SRV2413 703 4 Front Right Base Log SRV2412 704 5 Top Left Log SRV2413 705 6 Middle Left Cross Log SRV2413 706 7 Middle Right Cross Log SRV2413 707 8 Top Right Log SRV2413 708 9 Drywall Support 2...

Страница 23: ...V2413 702 3 Front Left Base Log SRV2413 703 4 Front Right Base Log SRV2413 704 5 Top Left Log SRV2413 705 6 Middle Left Cross Log SRV2413 706 7 Middle Right Cross Log SRV2413 707 8 Top Right Log SRV24...

Страница 24: ...t Left Base Log SRV2413 703 4 Front Right Base Log SRV2414 711 5 Top Left Log SRV2413 705 6 Middle Left Cross Log SRV2413 706 7 Middle Right Cross Log SRV2413 707 8 Top Right Log SRV2414 712 9 Drywall...

Страница 25: ...4 Flex Ball Valve Assembly SRV302 320 Y 10 5 Valve NG 750 500 Y Valve LP 2155 501 Y 10 6 Male Connector Pkg of 5 303 315 5 10 7 Module SRV593 592 Y 10 8 Thermostat Wire Assembly SRV2118 170 Y 10 9 Mod...

Страница 26: ...r 530 299 Gasket Assembly 2118 080 Contains Burner neck shutter bracket vent seal cap valve plate and air passage gaskets Mineral Wool 050 721 Touch Up Paint TUP GBK 12 IPI CONVERSION KITS Conversion...

Страница 27: ...________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible for use and operati...