6
Majestic • QUARTZ32, QUARTZ36, QUARTZ42 Owner’s Manual • 2412-981 Rev. G • 5/18
C. BTU Specifications
A. Appliance Certification
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
NOTICE:
This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
2
Product Specific Information
This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
B. Glass Specifications
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous lo-
cations such as bathtub enclosures as defined by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certified to the re
-
quirements of
ANSI Z97.1
and
CPSC 16 CFR 1202
(Safety Glazing Certification Council
SGCC# 1595
and
1597
. Architectural Testing, Inc. Reports
02-31919.01
and
02-31917.01
).
This statement is in compliance with
CPSC 16 CFR Sec-
tion 1201.5
“Certification and labeling requirements”
which refers to
15
U.S. Code
(USC) 2063
stating “…Such
certificate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
MODELS:
QUARTZ32IN, QUARTZ32IL,
QUARTZ36IN, QUARTZ36IL
QUARTZ42IN, QUARTZ42IL
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Direct Vent Heater
STANDARD:
ANSI Z21.88-2017 • CSA 2.33-2017
Installation and service of this
appliance should be performed
by qualified personnel. Hearth &
Home Technologies recommends
NFI certified professionals.
Models
(U.S. or Canada)
Maximum
Input BTU/h
Minimum
Input BTU/h
Orifice
Size
(DMS)
QUARTZ32IN
(NG)
(0-2000 FT)
21,000
15,000
#44
QUARTZ32IL
(PROPANE)
(0-2000 FT)
18,500
14,000
#55
QUARTZ36IN
(NG)
(0-2000 FT)
24,000
17,000
#42
QUARTZ36IL
(PROPANE)
(0-2000 FT)
20,500
16,000
#54
QUARTZ42IN
(NG)
(0-2000 FT)
28,500
20,000
#39
QUARTZ42IL
(PROPANE)
(0-2000 FT)
26,000
19,500
#53