Majestic MERIDIAN Series Скачать руководство пользователя страница 23

23

Majestic  •  MERID36IN, MERID36IL, MERID42IN, MERID42IL Owner’s Manual  •  2517-981 Rev. D  •  7/18

Intellifire™ Touch - (continued)

Symptom

Possible Cause

Corrective Action

Pilot sparks for 60 sec, but will not 

light, 3 Red/1 Green Lockout.

No gas supply.

Verify incoming gas line ball valve is ‘Open’.  Verify inlet pres-

sure is within requirement for gas type used.  Contact gas sup-

plier.

ECM has poor ground.

Verify  wiring,  check  valve  harness  black  wire  is  securely 

grounded to metal chassis.

Gas valve defective.

Check pilot valve solenoid kick and hold voltages during igni

-

tion cycle.  Kick V should be >1 V, hold V minimum 0.26 V.  If 

voltages are OK, replace gas valve.

Pliot lights but main burner does 

not light.   Pilot continues to spark 

for 60 sec then goes into 3 Red/1 

Green Lockout.

No flame detected. Flame 

rectification issue.

Check if white sense lead is securely connected to ‘S’ terminal 

of 

IFT-

ECM.  Check resistance of sense lead between sense 

rod tip and connector to 

IFT-

ECM, should be less than 1 ohm 

- if not, replace pilot assembly.  Check system ground, ensure 

black valve harness wire is securely attached to metal chassis.  

Check wiring for damage.  With system OFF, check resistance 

between tip of sense rod and pilot hood, should be resistance 

(>1 M-ohm). 

No flame detected or sense 

rod contamination. 

With  glass  assembly  installed,  verify  pilot  flame  is  engulfing 

flame sense rod on pilot assembly.  Verify inlet gas pressure 

is correct for gas type.  Polish flame sense rod with fine steel 

wool to remove any contaminants that may have accumulated.

Pilot lights and rectifies, but main 

burner does not light.

Main valve solenoid.

Check  if  green  wire  in  valve  harness  is  connected  to  green 

main valve solenoid.  Check main valve solenoid resistance, 

nominal is 60 ohms.  If open or shorted, replace valve.  Verify 

valve inlet pressure is correct for gas type.

Pilot and main do not light, ECM 

goes into 5 Red/1 Green Lockout.

Power Vent (PV) Failure.

Power Vent blower defective - check wiring to 

IFT-

ACM, check 

if blower is working.  Check if PV pressure switch is connected 

to brown and black wire in 6-pin valve wire harness.  Check if 

pressure switch is closed (shorted) when PV blower is running.  

Refer to PV troubleshooting instructions. 

Appliance lights and runs for a few 

minutes then shuts down and/or 

appliance cycle ON and OFF with 

less than 60 sec of ON time. 

Shorted or loose connection in 

flame detection circuit.

Check if white sense lead is securely connected to ‘S’ terminal 

of 

IFT-

ECM.  Check resistance of sense lead between sense 

rod tip and connector to 

IFT-

ECM, should be less than 1 ohm 

- if not, replace pilot assembly.  Check system ground, ensure 

black valve harness wire is securely attached to metal chassis.  

Check wiring for damage.  With system OFF, check resistance 

between tip of sense rod and pilot hood, should be resistance 

(>1 M-ohm). 

Poor flame rectification or 

contaminated sense rod. 

With  glass  assembly  installed,  verify  pilot  flame  is  engulfing 

flame sense rod on pilot assembly.  Verify inlet gas pressure 

is correct for gas type.  Polish flame sense rod with fine steel 

wool to remove any contaminants that may have accumulated.  

Verify no soot deposits are in sense rod to pilot hood gap.

Logs are set up wrong. 

Remove and re-install logs per the log placement instructions.

Damaged pilot assembly.

Verify  the  pilot  assembly  ceramic  insulator  around  the  flame 

sensing  rod  is  not  cracked,  damaged  or  loose.    Check  re

-

sistance between tip of sense rod and 

IFT-

ECM connector, 

should be less than 1 ohm.  Replace pilot assembly if damage 

is detected.

Содержание MERIDIAN Series

Страница 1: ...ppliance installation manual for additional Commonwealth of Massachusetts requirements DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier d...

Страница 2: ...___________________________________________________ Gas and Electric Information Serial Number Type of Gas Model Number Not Not for use use with with solid solid fuel fuel Ne Ne doit doit pas entre en...

Страница 3: ...cations 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV Guidelines 8 E Before Lighting Appliance 10...

Страница 4: ...begins on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an...

Страница 5: ...IONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur T...

Страница 6: ...rtification NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE This appliance is tested and approved as either supplemen tal room heat or as a decorative appliance It should not be factored as primary heat...

Страница 7: ...NEVER touch the fireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts...

Страница 8: ...XED GLASS ASSEMBLY NOT SHOWN SECTION 4 B MANTEL HEARTH not required FAN KIT SECTION 3 H CLEAR SPACE SECTION 3 A GRATE Figure 3 3 Good Faith Wall Surface Temperatures Above Appliance D Good Faith Wall...

Страница 9: ...turer and from model to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers max...

Страница 10: ...als have been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensur...

Страница 11: ...gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance if any part h...

Страница 12: ...an speed or to turn the fan OFF The fan speed dynamic icon is used to change the setting G Appliance Break In Follow the initial break in procedure below to cure the materials used to manufacture the...

Страница 13: ...gram is included in the Electrical section of the appliance Installation Manual 3 Turn the appliance on according to the instructions below for the appropriate type of control Standard Wall Switch or...

Страница 14: ...hen switched to the OFF position while the appliance is operating the system will shut down ON Position The appliance will ignite and run continuously at the HI flame setting No adjustment in flame he...

Страница 15: ...be placed in the battery pack while using the transformer Remove batteries before using the transformer and unplug the transformer before installing the batteries Battery polarity must be correct or m...

Страница 16: ...cessive lint from carpeting bedding material et cetera It is im perative that control compartments burners and circulat ing air passageways of the appliance be kept clean Any safety screen guard or ba...

Страница 17: ...are not blocked Vacuum and dust surfaces Remove batteries from remote controls Unplug 6 volt adapter plug on IPI models Remote Control Frequency Seasonally By Homeowner Tools needed Replacement batter...

Страница 18: ...or replace as required Verify that there is not a short in flame sense circuit by checking continuity between pilot hood and flame sensing rod Replace pilot as necessary Figure 4 2 IPI Pilot Flame Pat...

Страница 19: ...mming glass Avoid abrasive cleaners DO NOT clean glass while it is hot Remove decorative front from fireplace and set aside on work surface Pull the four glass assembly latches out of the groove on th...

Страница 20: ...osits left by oils from the manufacturing process A non abrasive cleaner such as gas fireplace glass cleaner may be necessary See your dealer Metallic noise Noise is caused by metal expanding and cont...

Страница 21: ...t not directly in front of it The remote acts as the thermostat Remote is placed in the path of an air draft or vent Move the remote away from the direct path of air flow The remote acts as the thermo...

Страница 22: ...M slider switch is in ON or IFT REM position Verify AC power available to junction box Verify AC DC adap tor is plugged into junction box and ECM Verify AC DC adaptor output voltage is between 5 7 6 3...

Страница 23: ...green main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM...

Страница 24: ...operate your fireplace For safety Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children See your dealer if you have questio...

Страница 25: ...ART NUMBER Log Assembly LOGSDBDV36 Y 1 Log A SRV2397 701 2 Log B SRV2397 702 3 Log C SRV2397 703 4 Log D SRV2397 704 5 Log E SRV2397 705 6 Log F SRV2397 706 7 Insulation Board 2166 136 8 Glass Heat Sh...

Страница 26: ...NTS PART NUMBER Log Assembly LOGSDBDV42 Y 1 Log A SRV2397 701 2 Log B SRV2397 702 3 Log C SRV2397 703 4 Log D SRV2397 704 5 Log E Qty 3 req SRV2397 705 6 Log F SRV2397 706 7 Insulation Board 2170 136...