J.  Detailed Component Operating 

Instructions - IntelliFire™ Touch

IFT-ECM Detailed Operating Instruction

Figure 3.6   IFT-ECM

3 POSITION SWITCH

TOP VIEW

LED INDICATOR

DANGER

Risk of Explosion 

DO NOT

 cycle the ON/OFF/REM selector 

switch more than one time within a five minute 

period.  Gas may accumulate in firebox.  Call 

a qualified service technician.

DANGER

Risk of Explosion 

DO NOT

 cycle the ON/OFF/REM selector 

switch more than one time within a five minute 

period.  Gas may accumulate in firebox.  Call 

a qualified service technician.

4.  An IFT-ECM reset is required if the module is in a 

lock-out condition.  When this occurs, the appliance 

is shut down and the IFT-ECM status indicator LED 

will be blinking a RED/GREEN error code along with a 

one-time audible double- beep.  If the IFT-ECM is in a 

lock-out condition, refer to the troubleshooting chart to 

interpret the error code and take corrective action as 

required.  To reset the IFT-ECM after a lock-out error

CAUTION! 

Risk  of  burns! 

Appliance surfaces are hot 

when  operating  and  during  cool  down.  Use  care  and 

wear gloves when opening the front and accessing com

-

ponents inside the appliance.

 

       -  Be aware the appliance may be HOT, use  

          care in accessing the IFT-ECM. 

 

       -  Set the IFT-ECM 3-position selector switch to        

          OFF position. 

 

The IFT-RC400 and IFT-RC150 remotes are an option 

for these models.

1.  The Electronic Control Module (IFT-ECM) has a 

three-position ON/OFF/REMOTE selector switch 

that must be set for proper operation. See Figure 

3.6.  When changing switch positions, it is important 

to pause in each position for 1-2 seconds. 

 

OFF Position:   

 

The appliance will not respond to any commands 

from a wired wall switch, IFT-RC150  or IFT-RC400 

remote controls.  The unit should be in the OFF 

position during service, fuel conversion, and to 

reset the IFT-ECM in the event the system goes 

into a LOCK-OUT mode as the result of a system 

error.  When switched to the OFF position while the 

appliance is operating, the system will shut down. 

 

ON  Position:   

 

The  appliance  will  ignite  and  run continuously at 

the HI flame setting.  No adjustment in flame height 

is possible.  

 

Remote Position:   

 

The remote position allows operation of the 

appliance from a wired wall switch, IFT-RC400 or 

IFT-RC150 remote controls.  The IFT-ECM switch 

must be in this position to pair the IFT-ECM with the 

IFT-ACM (if installed), and/or IFT-RC400 and IFT-

RC150 remote controls.  See the IFT-RC400 or IFT-

RC150 installation manual for detailed instructions 

on pairing the IFT-ECM with the remote controls. 

After successfully pairing a IFT-RC400, all installed 

accessories can be controlled by the IFT-RC400 

(see IFT-RC400 user manual).  The  RC150 allows 

the user to turn ON/OFF the flame in the appliance 

and activate the Cold Climate mode if desired.  The 

IFT-ECM has a safety feature that will automatically 

shut down the fireplace after 9 hours of continuous 

operation without receiving a command from the 

IFT-RC400 or IFT-RC150. 

2.  If multiple control options are installed, the IFT-ECM 

will respond to the last command from the wired wall 

switch, IFT-RC400 or IFT-RC150.  The wired wall 

switch is NOT available if a Power Vent is used.

The IFT-ECM has a safety feature that will 

automatically  shut  down  the  fireplace  after 

9 hours of continuous operation in the ON 

position, except when operated in active 

thermostat mode.  

3.  The Pilot button on the IFT-ECM activates the Cold 

Climate function of the fireplace.  This function lights 

the pilot flame ONLY to provide enough heat in the 

firebox to reduce condensation in cool, high humidity 

ambient conditions.  To activate the Cold Climate 

press and hold the Pilot button for one second and  

release.  The IFT-ECM will flash two green LED blinks, 

 

beep twice and light and rectify the pilot flame when 

 

pressed to activate.  To turn off Cold Climate, press  

and hold the Pilot button for one second and release.   

The IFT-ECM will flash one green LED blink, beep once 

 

and shut down the pilot flame.  If remote controls are 

 

paired with the IFT-ECM, this feature can also be  

activated with the IFT-RC400 and/or IFT-RC150.

Содержание MERIDIAN Series

Страница 1: ...ppliance installation manual for additional Commonwealth of Massachusetts requirements DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier d...

Страница 2: ...___________________________________________________ Gas and Electric Information Serial Number Type of Gas Model Number Not Not for use use with with solid solid fuel fuel Ne Ne doit doit pas entre en...

Страница 3: ...cations 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV Guidelines 8 E Before Lighting Appliance 10...

Страница 4: ...begins on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an...

Страница 5: ...IONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur T...

Страница 6: ...rtification NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE This appliance is tested and approved as either supplemen tal room heat or as a decorative appliance It should not be factored as primary heat...

Страница 7: ...NEVER touch the fireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts...

Страница 8: ...XED GLASS ASSEMBLY NOT SHOWN SECTION 4 B MANTEL HEARTH not required FAN KIT SECTION 3 H CLEAR SPACE SECTION 3 A GRATE Figure 3 3 Good Faith Wall Surface Temperatures Above Appliance D Good Faith Wall...

Страница 9: ...turer and from model to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers max...

Страница 10: ...als have been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensur...

Страница 11: ...gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance if any part h...

Страница 12: ...an speed or to turn the fan OFF The fan speed dynamic icon is used to change the setting G Appliance Break In Follow the initial break in procedure below to cure the materials used to manufacture the...

Страница 13: ...gram is included in the Electrical section of the appliance Installation Manual 3 Turn the appliance on according to the instructions below for the appropriate type of control Standard Wall Switch or...

Страница 14: ...hen switched to the OFF position while the appliance is operating the system will shut down ON Position The appliance will ignite and run continuously at the HI flame setting No adjustment in flame he...

Страница 15: ...be placed in the battery pack while using the transformer Remove batteries before using the transformer and unplug the transformer before installing the batteries Battery polarity must be correct or m...

Страница 16: ...cessive lint from carpeting bedding material et cetera It is im perative that control compartments burners and circulat ing air passageways of the appliance be kept clean Any safety screen guard or ba...

Страница 17: ...are not blocked Vacuum and dust surfaces Remove batteries from remote controls Unplug 6 volt adapter plug on IPI models Remote Control Frequency Seasonally By Homeowner Tools needed Replacement batter...

Страница 18: ...or replace as required Verify that there is not a short in flame sense circuit by checking continuity between pilot hood and flame sensing rod Replace pilot as necessary Figure 4 2 IPI Pilot Flame Pat...

Страница 19: ...mming glass Avoid abrasive cleaners DO NOT clean glass while it is hot Remove decorative front from fireplace and set aside on work surface Pull the four glass assembly latches out of the groove on th...

Страница 20: ...osits left by oils from the manufacturing process A non abrasive cleaner such as gas fireplace glass cleaner may be necessary See your dealer Metallic noise Noise is caused by metal expanding and cont...

Страница 21: ...t not directly in front of it The remote acts as the thermostat Remote is placed in the path of an air draft or vent Move the remote away from the direct path of air flow The remote acts as the thermo...

Страница 22: ...M slider switch is in ON or IFT REM position Verify AC power available to junction box Verify AC DC adap tor is plugged into junction box and ECM Verify AC DC adaptor output voltage is between 5 7 6 3...

Страница 23: ...green main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM...

Страница 24: ...operate your fireplace For safety Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children See your dealer if you have questio...

Страница 25: ...ART NUMBER Log Assembly LOGSDBDV36 Y 1 Log A SRV2397 701 2 Log B SRV2397 702 3 Log C SRV2397 703 4 Log D SRV2397 704 5 Log E SRV2397 705 6 Log F SRV2397 706 7 Insulation Board 2166 136 8 Glass Heat Sh...

Страница 26: ...NTS PART NUMBER Log Assembly LOGSDBDV42 Y 1 Log A SRV2397 701 2 Log B SRV2397 702 3 Log C SRV2397 703 4 Log D SRV2397 704 5 Log E Qty 3 req SRV2397 705 6 Log F SRV2397 706 7 Insulation Board 2170 136...

Страница 27: ...8 106 15 4 Valve Bracket 2118 104 15 5 Battery Pack SRV2326 134 Y 15 6 Power Supply SRV2326 131 Y 15 7 Flex Ball Valve Assembly SRV302 320 Y 15 8 Valve NG 2166 302 Y Valve Propane 2166 303 Y 15 9 Male...

Страница 28: ...rt Assembly Qty 4 req 2382 400 Y Jumper Wire SRV2187 198 Y Lava Rock 4021 297 Mineral Wool SRV14333 Refractory Set Tavern Brown MERID36IN IL BRICK36MERTB MERID42IN IL BRICK42MERTB Refractory Set Cotta...

Страница 29: ...______________________ ________________________________________________________________________________ ________________________________________________________________________________ _______________...

Отзывы: