background image

19

Majestic  •  MERC32IN, MERC32IL, MERC32VN, MERC32VL Owner’s Manual  •   2401-981 Rev. L  •  9/20

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.  If you do 

experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem and 

the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.  Contact 

your dealer to arrange a service call by a qualified service technician.

B.  Troubleshooting - IntelliFire

®

 Ignition System

Symptom

Possible Cause

Corrective Action

1. Pilot won’t light. 

The ignitor/module 

makes noise, but no 

spark.

A.  Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are 

connected to correct terminals on module and pilot assembly.

B.  Loose connections or electrical 

shorts in the wiring.

Verify no loose connections or electrical shorts in wiring from mod-

ule to pilot assembly. Verify connections underneath pilot assem-

bly are tight; also verify connections are not grounding out to metal 

chassis, pilot burner, pilot enclosure, mesh screen if present, or any 

other metal object. 

C.  Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be 

approximately .095 in. (2.41 mm) to .135 in. (3.43 mm).

D.  Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove 

ignitor wire “I” from module. Place a grounded wire about 3/16 in. (5 

mm) away from “I” terminal on module. Place ON/OFF rocker switch 

or wall switch in ON position. If there is no spark at “I” terminal module 

must be replaced. If there is a spark at “I” terminal, module is fine. 

Inspect pilot assembly for shorted sparker wire or cracked insulator 

around electrode. Replace pilot if necessary.

2. Pilot won’t light, 

there is no noise or 

spark.

A.  No power or transformer installed 

incorrectly.

Verify that transformer is installed and plugged into module. Check 

voltage of transformer under load at spade connection on module 

with ON/OFF switch in ON position. Acceptable readings of a good 

transformer are between 3.2 and 2.8 volts AC.

B.  A shorted or loose connection in 

wiring configuration or wiring har

-

ness.

Remove and reinstall the wiring harness that plugs into module. 

Verify there is a tight fit. Verify pilot assembly wiring to module. Re

-

move and verify continuity of each wire in wiring harness.  Replace 

any damaged components.

C. Improper wall switch wiring.

Verify that 110-120 VAC power is “ON” to junction box.

D.  Module not grounded.

Verify black ground wire from module wire harness is grounded to 

metal chassis of appliance.

E.  Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove 

ignitor  wire  “I”  from  module.  Place  ON/OFF  rocker  switch  or  wall 

switch  in  ON  position.  If  there  is  no  spark  at  “I”  terminal  module 

must be replaced. If there is a spark at “I” terminal, module is fine. 

Inspect pilot assembly for shorted sparker wire or cracked insulator 

around electrode.

3. Pilot sparks, but 

Pilot will not light.

A.  Gas supply.

Verify that incoming  gas line ball valve is “open”. Verify that inlet 

pressure reading is within acceptable limits.

B.  Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be 

approximately .095 in. (2.41 mm) to .135 in. (3.43 mm).

C.  Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

D.  Module voltage output / Valve/Pilot 

solenoid ohms readings.

Verify battery voltage is at least 2.7 volts. Replace batteries if volt-

age is below 2.7.

Содержание MERC32

Страница 1: ...ts for location of additional Commonwealth of Massachusetts requirements Models MERC32IN MERC32IL MERC32VN MERC32VL DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDR...

Страница 2: ...Gaz N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Approved...

Страница 3: ...ions Tempered 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV Guidelines 8 E...

Страница 4: ...ributor whichever occurs earlier However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installa on or occupancy date The warrant...

Страница 5: ...local building codes 3 shipping or improper handling 4 improper opera on abuse misuse con nued opera on with damaged corroded or failed components accident or improperly incorrectly performed repairs...

Страница 6: ...roduct is listed to ANSI standards for Vented Gas Fireplace Heaters and applicable sections of Gas Burn ing Heating Appliances for Manufactured Homes and Recreational Vehicles and Gas Fired Appliances...

Страница 7: ...t remove the fixed glass assembly so you can de tect presence of residual gas build up See Standing Pilot Lighting instructions and Maintenance Tasks 3 3 Important Safety and Operating Information Cle...

Страница 8: ...r natural gas or propane Make sure the appliance is compatible with gas type selected for installation site Conversions must be made by a qualified service technician using Hearth Home Technologies sp...

Страница 9: ...temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable opera ng temperatures id...

Страница 10: ...ir shutter adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper position and that the integral barrier is in place WARNING Risk of Fire or Asphyxiation DO NO...

Страница 11: ...done by a licensed or Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If...

Страница 12: ...THE CON TROL VALVE Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assis...

Страница 13: ...variable burn rate which is controlled by the HI LO knob on the gas valve Therefore the flame height is adjustable The HI LO knob is shown in Figure 3 6 It is located in the control cavity of the app...

Страница 14: ...t is used because the pilot burner flame is only present when the main burner is operating When the main burner is off the pilot is also off NOTICE Batteries should not be placed in the battery pack w...

Страница 15: ...e hand and secure glass latches with the other hand Inspect and operate all glass latches to ensure they move freely and no obstructions are present Reinstall decorative front B Maintenance Tasks Home...

Страница 16: ...s or sheds Inspect for corrosion or separation Verify weather stripping sealing and flashing remains intact Inspect draft shield to verify it is not damaged or missing C Maintenance Tasks Qualified Se...

Страница 17: ...or leaking Check for smooth lighting and ignition carryover to all ports Verify that there is no ignition delay Inspect and ensure the lighting of the main burner occurs within four seconds of the mai...

Страница 18: ...3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing process A non abrasive cleaner such as gas fireplace glass cleaner may be necessary See your dealer Metallic noi...

Страница 19: ...e Inspect pilot assembly for shorted sparker wire or cracked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark A No power or transformer installed in...

Страница 20: ...rifice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod C Module is...

Страница 21: ...e that the thermocouple connection at the gas valve is fully in serted and tight hand tighten plus 1 4 turn Verify proper voltage output from the thermocouple to the valve Place one millivolt meter le...

Страница 22: ...Refill the fuel tank B Improper gas inlet pressure Natural gas should be 5 10 in w c Propane should be 11 13 in w c Verify pressure with manometer C Inner vent pipe leaking exhaust gases back into th...

Страница 23: ...ou have questions Install approved accessories per instructions included with accessories Contact your dealer for a list of ap proved accessories WARNING Risk of Fire and Electric Shock Use ONLY Heart...

Страница 24: ...397 705 6 Log 6 SRV2397 705 7 Burner Assembly 2355 007 Y 8 Base Pan 2355 110 9 Glass Door Assembly GLA 550TR Y 10 Fire Screen Front SRV2401 021 Y 11 Hood 2115 230 12 Drywall Support 2391 119 13 Juncti...

Страница 25: ...2107 070 Y Pilot Tube SRV485 301 Y 15 2 3 Hole Grommet SRV2118 420 15 3 Valve Bracket 2118 104 15 4 Flexible Gas Connector SRV302 320 Y 15 5 Valve NG 750 500 Y Valve LP 750 501 Y 15 6 Thermostat Wire...

Страница 26: ...PTION COMMENTS PART NUMBER 16 1 Pilot Assembly NG 2103 010 Y Pilot Assembly LP 2103 011 Y Pilot Tube SRV485 301 Y 16 2 3 Hole Grommet SRV2118 420 16 3 Valve Bracket 2118 104 16 4 Flexible Gas Connecto...

Страница 27: ...________________________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party respons...

Отзывы: