Majestic MERC32 Скачать руководство пользователя страница 13

13

Majestic  •  MERC32IN, MERC32IL, MERC32VN, MERC32VL Owner’s Manual  •   2401-981 Rev. L  •  9/20

I. Operation During A Power Outage

The IntelliFire intermittent pilot ignition system comes 

with  a  battery  backup  system  that  enables  the  system 

to operate in a power outage. A factory-installed battery 

pack is located in the control cavity of the appliance. See 

Figure 3.6.  Batteries should not be placed in the battery 

tray while using electrical power to operate the fireplace.   

Remove batteries from battery tray when power has been 

restored. 

To Operate Fireplace Using Battery Power (DC):

1.  Access the control cavity of the appliance.  See Figure 

3.6 for location.  The decorative front may need to be 

removed. 

2.  Locate the battery tray and insert two D cell batteries.  

Battery polarity must be correct or module damage will 

occur.  A complete wiring diagram is included in the 

Electrical section of the Appliance Installation Manual.

3.  Turn the appliance on according to the instructions 

below for the appropriate type of control:

Standard Wall Switch or Factory-Installed ON/OFF 

Switch: 

•   Toggle the switch as you would under normal 

circumstances.

Multifunctional Wired Wall Switch Control System: 

•    Locate the wired wall switch control module in control 

cavity.

•   Locate battery operation switch on the side of the 

module.

•    Slide the switch to the BATTERY ON or ON position.  

NOTICE: 

Batteries should only be used as a power source 

in  the  event  of  an  emergency  power  outage.  Batteries 

should not be used as a primary long-term power source. 

NOTICE:  

Some functionality will be lost when using battery 

backup including remote control, fan, lights, or any other 

auxiliary  functions  that  require  household  110-120  VAC 

power.

H.  Heat Management

Heat Output

The Mercury models have a variable burn rate which is 

controlled by the HI/LO knob on the gas valve. Therefore 

the flame height is adjustable. The HI/LO knob is shown 

in Figure 3.6. It is located in the control cavity of the 

appliance.  The HI/LO knob may be adjusted as desired 

by turning clockwise to the HIGH position and by turning 

counterclockwise to the LO position. 

If an optional fan is installed, the fan speed is controlled 

by adjusting the speed control knob.  Turn the knob to 

increase the fan speed as desired. 

CONTROL 

CAVITY

VALVE

HI/LO KNOB

Figure 3.6  Control Cavity/Valve Location

To Return to Operation Using Electrical (AC) Power:

Standard Wall Switch or Factory-Installed ON/OFF 

Switch: 
•   Toggle the switch to OFF and remove the batteries 

from the battery tray.  Replace decorative front on 

appliance.

Multifunctional Wired Wall Switch Control System: 
•   Slide the switch to the OFF position.  Remove the 

batteries from the battery tray.  Replace decorative 

front on appliance.

IntelliFire Ignition System

G.  Appliance Break-In

NOTICE! 

Open windows for air circulation during fire

-

place break-in.

•  Some people may be sensitive to smoke and odors.

•  Smoke detectors may activate.

Follow  the  initial  break-in  procedure  below  to  cure  the 

materials  used  to  manufacture  the  fireplace  and  the 

finishing materials around it.

• The fireplace should be run three to four hours 

continuously on high.  

•  Turn the fireplace off and allow it to cool completely.
•  Remove fixed glass assembly. See Section 4.B.
•  Clean fixed glass assembly. See Section 4.B.
•  Replace the fixed glass assembly. 

Note:

 Some installations may require additional run time 

to cure.  If odors persist after the initial break-in period, 

run  the  fireplace  for  an  additional  three  to  four  hours 

continuously on high.  

Note: 

 Some IPI systems have a safety feature that 

automatically  shuts  down  the  fireplace  after  9  hours  of 

continuous operation without receiving a command from 

the remote control.  If this occurs, restart the appliance.

Содержание MERC32

Страница 1: ...ts for location of additional Commonwealth of Massachusetts requirements Models MERC32IN MERC32IL MERC32VN MERC32VL DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDR...

Страница 2: ...Gaz N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Approved...

Страница 3: ...ions Tempered 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV Guidelines 8 E...

Страница 4: ...ributor whichever occurs earlier However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installa on or occupancy date The warrant...

Страница 5: ...local building codes 3 shipping or improper handling 4 improper opera on abuse misuse con nued opera on with damaged corroded or failed components accident or improperly incorrectly performed repairs...

Страница 6: ...roduct is listed to ANSI standards for Vented Gas Fireplace Heaters and applicable sections of Gas Burn ing Heating Appliances for Manufactured Homes and Recreational Vehicles and Gas Fired Appliances...

Страница 7: ...t remove the fixed glass assembly so you can de tect presence of residual gas build up See Standing Pilot Lighting instructions and Maintenance Tasks 3 3 Important Safety and Operating Information Cle...

Страница 8: ...r natural gas or propane Make sure the appliance is compatible with gas type selected for installation site Conversions must be made by a qualified service technician using Hearth Home Technologies sp...

Страница 9: ...temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable opera ng temperatures id...

Страница 10: ...ir shutter adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper position and that the integral barrier is in place WARNING Risk of Fire or Asphyxiation DO NO...

Страница 11: ...done by a licensed or Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If...

Страница 12: ...THE CON TROL VALVE Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assis...

Страница 13: ...variable burn rate which is controlled by the HI LO knob on the gas valve Therefore the flame height is adjustable The HI LO knob is shown in Figure 3 6 It is located in the control cavity of the app...

Страница 14: ...t is used because the pilot burner flame is only present when the main burner is operating When the main burner is off the pilot is also off NOTICE Batteries should not be placed in the battery pack w...

Страница 15: ...e hand and secure glass latches with the other hand Inspect and operate all glass latches to ensure they move freely and no obstructions are present Reinstall decorative front B Maintenance Tasks Home...

Страница 16: ...s or sheds Inspect for corrosion or separation Verify weather stripping sealing and flashing remains intact Inspect draft shield to verify it is not damaged or missing C Maintenance Tasks Qualified Se...

Страница 17: ...or leaking Check for smooth lighting and ignition carryover to all ports Verify that there is no ignition delay Inspect and ensure the lighting of the main burner occurs within four seconds of the mai...

Страница 18: ...3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing process A non abrasive cleaner such as gas fireplace glass cleaner may be necessary See your dealer Metallic noi...

Страница 19: ...e Inspect pilot assembly for shorted sparker wire or cracked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark A No power or transformer installed in...

Страница 20: ...rifice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod C Module is...

Страница 21: ...e that the thermocouple connection at the gas valve is fully in serted and tight hand tighten plus 1 4 turn Verify proper voltage output from the thermocouple to the valve Place one millivolt meter le...

Страница 22: ...Refill the fuel tank B Improper gas inlet pressure Natural gas should be 5 10 in w c Propane should be 11 13 in w c Verify pressure with manometer C Inner vent pipe leaking exhaust gases back into th...

Страница 23: ...ou have questions Install approved accessories per instructions included with accessories Contact your dealer for a list of ap proved accessories WARNING Risk of Fire and Electric Shock Use ONLY Heart...

Страница 24: ...397 705 6 Log 6 SRV2397 705 7 Burner Assembly 2355 007 Y 8 Base Pan 2355 110 9 Glass Door Assembly GLA 550TR Y 10 Fire Screen Front SRV2401 021 Y 11 Hood 2115 230 12 Drywall Support 2391 119 13 Juncti...

Страница 25: ...2107 070 Y Pilot Tube SRV485 301 Y 15 2 3 Hole Grommet SRV2118 420 15 3 Valve Bracket 2118 104 15 4 Flexible Gas Connector SRV302 320 Y 15 5 Valve NG 750 500 Y Valve LP 750 501 Y 15 6 Thermostat Wire...

Страница 26: ...PTION COMMENTS PART NUMBER 16 1 Pilot Assembly NG 2103 010 Y Pilot Assembly LP 2103 011 Y Pilot Tube SRV485 301 Y 16 2 3 Hole Grommet SRV2118 420 16 3 Valve Bracket 2118 104 16 4 Flexible Gas Connecto...

Страница 27: ...________________________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party respons...

Отзывы: