Appliance Setup
A. Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle fixed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
•
DO NOT
strike, slam or scratch glass.
•
DO NOT
operate fireplace with glass removed, cracked,
broken or scratched.
•
Replace as a complete assembly.
CAUTION! Risk of Injury! Glass assembly installation
and removal must be performed by a qualified service
technician. See chart below for glass assembly weights.
• MARQ42IN MODELS: It is recommended that Glass
installation and removal be performed by two quali-
fied service technicians.
Figure 11.2. Glass Clip Tool Location
Figure 11.3. Inserting Glass Clip Tool
Figure 11.1. Glass Clip Tool
CAUTION! Risk of Cuts or Abrasions. Wear protective
gloves and safety glasses during installation. Sheet metal
edges are sharp.
Removing Fixed Glass Assembly
This fixed glass assembly is held in place by lower glass
clips, side clips and top retaining rail. To remove clips, en
-
gage the spring clips with the tool and pull tool out slightly.
1. The glass clip removal/installation tool is fastened to
the lower right corner of the appliance. Remove tool
by removing one screw. See Figure 11.1. If glass clip
removal tool becomes misplaced, a cotter pin removal
tool may be used.
2. To disengage bottom glass clips, position the glass
clip removal/installation tool parallel to the floor and
insert it about two inches into the gap between the
glass frame and the front bottom fireplace lip. Insert
the tool on the lower left side of the glass clip and
move to the right to engage the clip. Using one mo
-
tion, pull out slightly while pushing down to disengage
bottom glass clip. Repeat for the other bottom spring
clips. There are three on the MARQ36IN and four on
the MARQ42IN. See Figure 11.2 and Figure 11.3.
3. Disengage the left and right glass clips one at a time
using the glass clip removal/installation tool. Insert
tool from the top side of the side glass clip. Pull the
glass tool out slightly to disengage the side clip. See
Figure 11.7.
4. Grasp the left and right sides of the glass assembly
and carefully pull outward to remove the bottom from
the support tabs on the bottom glass clips. Lower the
glass to remove it from the top retainer rail.
NOTICE: Protect and prevent the hearth from damage by
covering it with a drop cloth.
Glass Weights
MARQ36IN
MARQ42IN
32 lbs
41 lbs
CAUTION! Risk of Injury! DO NOT put fingers under
glass frame. Fingers may get pinched by glass frame
during removal.