You have chosen the finest wood burning fireplace available.  Your fireplace has been designed for 

years of heating and viewing enjoyment.  Please take time to read this entire manual before installing 

or operating your fireplace.

l

isting

 

and

 c

ode

 a

ppRovals

The instructions contained in this manual provide the information necessary to install this fireplace in accordance 

with Underwriter’s Laboratories requirements and in compliance with the National Fire Protection Association 

Standard No. 211.  Some codes may require the fireplace and chimney be electrically grounded.  Before 

beginning the installation, you should check with local building officials to obtain required permits and assure 

compliance with local regulations and coded.  If you encounter problems with code requirements, contact your  

dealer for assistance.
These  Fireplace  models  are  listed  by  OMNI-Test  Laboratories,  Inc.  to  U.L.  127-standard  for  factory-built 

fireplaces.  The design of this fireplace and these instructions complied with applicable safety standard for a 

factory built fireplace in effect at the time the fireplace was manufactured.  You should be aware, however, that 

failure to install, operate, and maintain this or any other factory built fireplace properly can result in a house 

fire or other occurrences that could cause deaths, injuries, and property damages.  It is very important that the 

persons installing and/or supervising the installation of this fireplace have appropriate skills in using the tools 

and techniques required; and reading and comprehension skills sufficient to read and follow these instructions.  

These instructions contain warnings, cautions, and notes to emphasize important safety information.  To assure 

that safe and satisfactory service is received from this fireplace, please read the following special notices and 

all the contents of this manual.

t

able

 

oF

 c

ontents

c

ongRatulations

!

Listing and Code Approvals...........................................................................................................Below

Important Information..........................................................................................................................1

Operation Guidelines.........................................................................................................................2

Clearances  .................................................................................................................3-4 

Fireplace  Location  ................................................................................................................5

Installation  Preparation  ........................................................................................................6-7

Floor  Protection  .    ...............................................................................................................8-9

Fireplace  Components  ...................................................................................................10

Fireplace  Installation  .....................................................................................................11

Chimney Installation ...............................................................................................................12-13

Chimney  Offset  Installation  ............................................................................................14-15

Chimney Cap Installation ......................................................................................................16-17

Chimney Cap Chase Installation ......................................................................................................18

Outside Combustion Air Precautions and Recommendations ..............................................19-20

Combustion Air Assembly ...............................................................................................................21

Gas Appliance Installation .......................................................................................................22-23

Trim and Door Installation ................................................................................................................24

Fireplace Operation ...............................................................................................................25-26

Maintenance and Safety .........................................................................................................27-29

Repair Parts Diagram and List ................................................. .............................................30-31

Warranty...................................................................................................................................32-33

Содержание Majestic SB5400SS

Страница 1: ...SB5400SS Model Residential and Outdoor Fireplace Installation Operation and Maintenance Manual This fireplace is listed by OMNI Test Laboratories for use with L Series chimney system components...

Страница 2: ...ver that failure to install operate and maintain this or any other factory built fireplace properly can result in a house fire or other occurrences that could cause deaths injuries and property damage...

Страница 3: ...lly recommended for use in such areas Intended Product Usage The fireplace is designed to sit directly on a combustible floor The fireplace must be installed with clearances to combustible building ma...

Страница 4: ...g down to close the damper When the fireplace is not in use the damper should be closed to prevent cold air form entering the chimney as well as preventing warm air in the room from escaping up the ch...

Страница 5: ...SETS 15FT MIN HEIGHT 2 30 ELBOWS 21 FT MN HEIGHT 4 30 ELBOWS 86FT MAX HEIGHT CHIMNEY SUPPORT EVERY 25 FT FIRESTOP MODEL LF FS 2 REQUIRES 17x17 FRAMING 54 STORM COLLAR MODEL LC CHIMNEY CAP ROOF FLASHIN...

Страница 6: ...LCF FLAT FLASHING SHOWN OR EQUIVALENT L48 CHIMNEY SECTION 1 REQUIRED 8 FT MIN CLEARANCE AIR SPACE 1 1 2 16 MIN 27 7 8 23 1 2 28 MIN SCREENED OPENING MIN MIN 76 1 2 APPLIES WHEN GLASS DOORS ARE INSTALL...

Страница 7: ...1 8 L 3 6 39 5 16 76 11 16 L SERIES CHIMNEY SECTIONS 47 5 8 47 L48 35 5 8 35 17 5 8 17 11 5 8 11 L18 L36 L12 L18 L18 34 5 8 34 LINEAR GAIN L18 L36 52 LINEAR GAIN 52 5 8 L36 L36 70 5 8 70 LINEAR GAIN 1...

Страница 8: ...of the fireplace required spacing to combustible walls and some suggested fireplace locations When selecting a location choose one that is away from frequently opened doors central heat outlets or re...

Страница 9: ...material free space for the chimney to pass through If the chimney is to pass through living or storage spaces be sure there is adequate space to enclose the chimney to avoid personal contact with or...

Страница 10: ...ACE FLUE OUTLET HEIGHT STORM COLLAR FLASHING 612 OR 1212 LC CHIMNEY CAP FIRESTOP SPACER LF FS 2 2 AIR SPACE CLEARANCE TO COMBUSTIBLES 17 SQUARE OPENING IN JOIST 17 SQUARE OPENING IN JOIST 612 OR 1212...

Страница 11: ...essive strength to support the weight of the covering materials and persons standing on it and insulating qualities equal to or better than the 1 2 covering provided by the H2068 Figure 11 Figure 12 2...

Страница 12: ...developing the hearth extension materials must be firmly fastened in place Wall ties should be screwed to the face of the fireplace and imbedded in the mortar joints of brick stone or other non combus...

Страница 13: ...30 degree chimney incline through ceiling or floor 17 inch firestop spacer One required at each ceiling or floor level 6 12 12 12 pitch flashing for contemporary installation 0 6 12 pitch flashing for...

Страница 14: ...grounding the fireplace and chimney Chimney Installation In order to assure safe and satisfactory performance of the fireplace it is very important to properly install the chimney This is an importan...

Страница 15: ...ess down until the snap locks engage Continue the process adding the chimney sections on top of each other until the chimney is at least six inches above the roof opening on all sided As the chimney s...

Страница 16: ...x 20 17 x 20 5 8 17 x 21 3 8 17 x 22 1 4 17 x 23 ROOF PITCH 0 12 1 12 2 12 3 12 4 12 5 12 6 12 7 12 8 12 9 12 10 12 11 12 12 12 INSTALLATION OF FIRESTOP SPACER AT FLOOR LEVELS INSTALLATION OF FIRESTO...

Страница 17: ...minimum air space clearance to the chimney at the extremities of the offset It is recommended that enclosing material not follow the inclined portions of the chimney Offset Installation Sequence 1 Det...

Страница 18: ...ROOF AND INSTALL ROUND CHIMNEY CAP OR CHIMNEY HOUSING FIRESTOP SPACER DIAGONAL CHIMNEY ENCLOSURE RISE FIRESTOP SPACER 2 AIR SPACE CLEARANCE TO COMBUSTIBLES SUPPORT STRAPS DIAGONAL CHIMNEY ENCLOSURE O...

Страница 19: ...ce and slide the flashing over the chimney Adjust the chimney to assure that the proper minimum clearances are maintained 5 Nail the flashing securely in place with eight nails 6 Seal the crack betwee...

Страница 20: ...1 2 101 104 107 110 112 1 2 116 118 1 2 122 4 0 0 0 0 0 0 0 1 0 1 1 0 1 1 0 2 1 0 2 1 0 2 1 3 2 1 3 2 1 3 2 4 3 2 4 3 2 4 3 5 3 0 0 0 0 0 1 0 0 1 0 0 2 0 1 2 0 1 3 0 2 3 1 2 0 1 3 0 2 3 1 2 0 1 3 0 2...

Страница 21: ...s should be at least 24 inches apart to help prevent smoke from a fireplace in use from being drawn down the chimney of a fireplace that is not in use Additional spacing between caps or staggering the...

Страница 22: ...RESTOP SPACER TO OUTSIDE WALL DUCT EXTENDED TO MISS JOIST SECOND FLOOR LONGER LENGTH OF THE TUBE TO OUTSIDE INSULATION RING INSERT SHORTEST SIDE OF THE TUBE THROUGH THE FIREPLACE OUTER WRAP TO PROPERL...

Страница 23: ...an exterior location which is not likely to be accidentally blocked in any manner The assembly should be located above the snow line to prevent blockage by snow accumulation 3 The combustion air inlet...

Страница 24: ...yond the face of the wall to which the AK 4 inlet air vent will be attached The duct may be cut with a standard pocket knife use FP 4 U duct for maximum efficiency and safety Do not use a combustible...

Страница 25: ...NSI IAS AGA Z21 11 2 unvented room heater is installed in this fireplace a H2853 CANOPY must also be installed Warning Do not operate an unvented gas log set in this fireplace with the chimney removed...

Страница 26: ...ming and attaching the base to the supporting floor will further reduce the possibility of such a crack developing Wall ties should be fastened to the face of the fireplace with sheet metal screws and...

Страница 27: ...BLE MANTEL USE ONLY NON COMBUSTIBLE MATERIALS BELOW TOP OF SPACERS COMBUSTIBLE FRAMING MEMBERS TO TOP OF SPACERS 12 MAX 18 MIN FROM FIREPLACE OPENING TO BOTTOM OF COMBUSTIBLE MANTEL MANUFACTURER RECOM...

Страница 28: ...ore expensive but a little combined with other wood goes a long way Start your fire with a mixture of softwood and hardwood then add some fruit or nut wood for nostalgic aroma Since most woods will no...

Страница 29: ...quipped with glass doors close them DO NOT LEAVE CHILDREN OR PHYSICALLY OR MENTALLY HANDICAPPED OR SENILE PERSONS ALONE WITH A BURNING FIREPLACE You ll need a minimum of three logs preferably four to...

Страница 30: ...on to determine if a creosote buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire The chimney cap can be removed for inspection maintenance and c...

Страница 31: ...he installation of the fireplace 4 Do insulate the exterior walls surrounding the fireplace to prevent excessive heat loss from the fireplace 5 Do trim the face of the fireplace only with noncombustib...

Страница 32: ...hing and between the flashing roof 14 Don t dry clothing or other articles near the fireplace 15 Don t store or place flammable liquids gases or pressurized containers near the fireplace 16 Don t negl...

Страница 33: ...of parts needed Technical Service Department MHSC 149 Cleveland Drive Paris KY 40361 www mhsc com 10 9 8 7 6 5 4 3 2 1 SB5400SS PART NO 047647 050918 073104 067514 052874 053127 037391 067517 N A 070...

Страница 34: ...e before you purchase it Blowers or fans which are warranted separately Heat loss due to the passage of heat or air through or around the fireplace Also under our five year coverage we do not pay the...

Страница 35: ...33 53D9028 Attention Appliance Installer Please return these Operating and Installation Instructions to the Appliance for Consumer Use...

Страница 36: ...34 53D9028 AUGUST 2008 53D9028 Rev 3 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: