background image

23

Majestic  •  JADE32IN, JADE42IN, JADE42IL Owner’s Manual   •  2491-987 Rev. F  •  9/18

 

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.  If you do 

experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem and 

the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.  Contact 

your dealer to arrange a service call by a qualified service technician.

C. Troubleshooting

IntelliFire™ Touch

ECM LED Error 

Codes

Description

3 Red: 1 Green

IFT-RC400 error message:  ‘Appliance Safely Disabled’, pilot sparks for 60 sec, no flame 

rectification.

2 Red: 1 Green

IFT-RC400 display:  ‘Error Pilot Flame’, pilot valve solenoid not detected.

2 Red: 2 Green

Sparking feedback signal error, spark coil failure.

5 Red: 1 Green

IFT-RC400 display:  ‘Error Power Vent’ (if installed).

Error Codes:

Troubleshooting:

See Troubleshooting matrix for more detail on Lock-out Error Codes, Possible Causes and Corrective Actions.

Symptom

Possible Cause

Corrective Action

Pilot won’t light, module clicks but 

no spark 60 sec, 3 Red/1 Green 

Lock out.

Incorrect wiring.

Verify ‘S’ (White) sense wire and ‘I’ (orange) ignitor wire are 
connected to correct terminals on 

IFT-

ECM.

Loose connections or electrical 

shorts in wiring.

Verify no loose connections or electrical shorts in wiring from 

module to pilot assembly.  Verify wire insulation is not dam-

aged.  Verify wires are not grounding out to chassis, pilot burn-

er, or any other metal object.  Replace any damaged wires. 

Ignitor gap is too large.

Verify spark gap is approximately 0.095” (2.41 mm) to 0.135” 

(3.43 mm). 

Pilot won’t light, there is no noise 

or spark.

No AC power, AC/DC adaptor 

faulty, backup batteries (if 

being used) depleted, 

IFT-

ECM slider switch in OFF 

position.

Verify 

IFT-

ECM slider switch is in ON or 

IFT-

REM  position.  

Verify AC power available to junction box.  Verify AC/DC adap-

tor is plugged into junction box and ECM.  Verify AC/DC adaptor 

output voltage is between 5.7-6.3 Vdc.  If battery pack is used, 

check battery pack voltage is >4.2 V (if not, replace batteries). 

Shorted or loose connection 

in system wiring or wiring 

harness.

Verify system wiring configuration.  Remove and reinstall wir

-

ing  harness that plugs into module. Check continuity of wires 

in valve wiring harness.  Replace any damaged components. 

Poor or no system ground.

Verify black ground wire in valve harness is connected to metal 

chassis of fireplace. 

Pilot won’t light, there is no noise 

or spark, 2 Red/1 Green Lockout.

Pilot solenoid not detected.

Check if valve harness orange wire is connected to pilot so

-

lenoid  valve.    Check  pilot  solenoid  resistance,  nominal  is  40 

ohms.  If open or shorted, replace valve.  Check valve harness 

wire continuity, if open replace 6-pin harness.

Pilot won’t light, there is no noise 

or spark, 2 Red/2 Green Lockout.

Spark coil failure.

Replace ECM.

Содержание JADE42IN

Страница 1: ...itter See appliance installation manual for additional Commonwealth of Massachusetts requirements DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS...

Страница 2: ..._____________________________________________ Email _____________________________________________________________ Not Not for use use with with solid solid fuel fuel Ne Ne doit doit pas entre entre ut...

Страница 3: ...Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV Guidelines 8 E Before Lighting Appliance 11 F Lighting...

Страница 4: ...s on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an indepe...

Страница 5: ...RRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishe...

Страница 6: ...INTENDED FOR USE AS A PRIMARY HEAT SOURCE This appliance is tested and approved as either supplemen tal room heat or as a decorative appliance It should not be factored as primary heat in residential...

Страница 7: ...ireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To preven...

Страница 8: ...Wall Surface TV Guidelines NOTICE Temperatures listed above are taken with a temperature measuring probe as prescribed by the test standard used for appliance certification Temperatures on walls or ma...

Страница 9: ...nd from model to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum al...

Страница 10: ...al specifications If the maximum allowable operating temperature for TV is less than 100 degrees Fahrenheit you should not use your TV with this application as damage to your TV may occur Contact the...

Страница 11: ...ve been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that...

Страница 12: ...up plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance if any part has bee...

Страница 13: ...option allows you to bring the warmth from your fireplace to the rest of your home up to 20 feet away Safely place a TV 12 inches above the fireplace The Smart Wall TV Kit must be installed by a qual...

Страница 14: ...Insert four AA cell batteries Battery polarity must be correct or module damage will occur See Figure 3 6 A complete wiring diagram is included in the Electrical section of the appliance Installation...

Страница 15: ...lly pairing a IFT RC400 all installed accessories can be controlled by the IFT RC400 see IFT RC400 user manual The RC150 allows the user to turn ON OFF the flame in the appliance and activate the Cold...

Страница 16: ...appliance See Figure 3 8 Switch is located above the RESET label Hold reset switch down for one second and release A beep will signal module is reset Appliances with Wall Switch and Remote Turn wall s...

Страница 17: ...is gap is designed for positive placement when replacing the glass assembly See Figure 4 1 Clean glass with a non abrasive commercially available cleaner Light deposits Use a soft cloth with soap and...

Страница 18: ...support the glass at all times 3 Verify that the top two glass latches are engaged by vi sually verifying that glass latches have engaged both left and right tabs on the glass frame 4 Verify the bott...

Страница 19: ...l are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Decorative Fronts Surrounds Frequency Annually By Homeowner Tools needed Protective gloves stable work...

Страница 20: ...f the main gas valve opening Inspect for lifting or other flame problems Verify air shutter setting is correct See Installation Manual for required air shutter setting Verify air shutter is clear of d...

Страница 21: ...o see the pilot flame burn continually In an intermittent pilot ignition system IPI the pilot flame should turn off when appliance is turned off Some optional control systems available with IPI models...

Страница 22: ...laced in the path of an air draft or vent Move the remote away from the direct path of air flow The remote acts as the thermostat Flame Modulation The control system is designed to automatically adjus...

Страница 23: ...nnections or electrical shorts in wiring from module to pilot assembly Verify wire insulation is not dam aged Verify wires are not grounding out to chassis pilot burn er or any other metal object Repl...

Страница 24: ...main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes i...

Страница 25: ...ces sories with this appliance Using non listed accessories could result in a safety hazard and will void the warranty Remote Controls Wall Controls and Wall Switches After a qualified service technic...

Страница 26: ...al number when requesting service parts from your dealer or distributor Stocked at depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Non Combustible Support 2492 104 2 Top Fill 2492 135 3 Non Combustible...

Страница 27: ...170 Y 8 3 Grommet SRV2118 420 8 4 Burner Support Left and Right 1 Set 2491 169 8 5 Gasket 2025 407 8 6 Bulkhead W Flex Tube 4021 428 Y 8 7 Valve Bracket 2491 153 8 8 Flex Ball Valve Assembly 12 SRV30...

Страница 28: ...ial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Bronze Media Qty 3 req 2413 850 Exhaust Restrictor 530 299 Gasket Assemb...

Страница 29: ...g service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Header Heat Shield 2118 120 2 Non Combustible Support 2491 104 3 Top Fill 2491 135 4 Non Combus...

Страница 30: ...e 2106 170 Y 9 3 Grommet SRV2118 420 9 4 Burner Support Left and Right 1 Set 2491 169 9 5 Gasket 2025 407 9 6 Bulkhead W Flex Tube 4021 428 Y 9 7 Valve Bracket 2491 153 9 8 Flex Ball Valve Assembly 12...

Страница 31: ...serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Bronze Media Qty 3 req 2413 850 Exhaust Restrictor 530 299 Gasket As...

Страница 32: ...________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible for use and operati...

Отзывы: