J.  Detailed Component Operating 

Instructions - Intellifire™ Touch

IFT-ECM Detailed Operating Instruction

Figure 3.7  IFT-ECM

3 POSITION SWITCH

TOP VIEW

LED INDICATOR

DANGER

Risk of Explosion 

DO NOT

 cycle the ON/OFF/REM selector 

switch more than one time within a five minute 

period.  Gas may accumulate in firebox.  Call 

a qualified service technician.

DANGER

Risk of Explosion 

DO NOT

 cycle the ON/OFF/REM selector 

switch more than one time within a five minute 

period.  Gas may accumulate in firebox.  Call 

a qualified service technician.

1.  The Electronic Control Module (IFT-ECM) has a 

three-position ON/OFF/REMOTE selector switch 

that must be set for proper operation. See Figure 

3.7.  When changing switch positions,it is important 

to pause in each position for 1-2 seconds. 

 

OFF Position:   

 

The appliance will not respond to any commands 

from a wired wall switch, IFT-RC150  or IFT-RC400 

remote controls.  The unit should be in the OFF 

position during installation, service, backup battery 

installation, fuel conversion and to reset the IFT-

ECM in the event the system goes into a LOCK-

OUT mode as the result of a system error.  When 

switched to the OFF position while the appliance is 

operating, the system will shut down. 

 

ON  Position:   

 

The  appliance  will  ignite  and  run continuously at 

the HI flame setting.  No adjustment in flame height 

is possible.  

 

The IFT-ECM has a safety feature that will 

automatically shut down the fireplace after 

9 hours of continuous operation in the ON 

position.   

 

Remote Position:   

 

The remote position allows operation of the 

appliance from a wired wall switch, IFT-RC400 or 

IFT-RC150 remote controls.  The IFT-ECM switch 

must be in this position to pair the IFT-ECM with the 

IFT-ACM (if installed), and/or IFT-RC400 and IFT-

RC150 remote controls.  See the IFT-RC400 or IFT-

RC150 installation manual for detailed instructions 

on pairing the IFT-ECM with the remote controls. 

After successfully pairing a IFT-RC400, all installed 

accessories can be controlled by the IFT-RC400 

(see IFT-RC400 user manual).  The  RC150 allows 

the user to turn ON/OFF the flame in the appliance 

and activate the Cold Climate mode if desired.  The 

IFT-ECM has a safety feature that will automatically 

shut down the fireplace after 9 hours of continuous 

operation without receiving a command from the 

IFT-RC400 or IFT-RC150. 

2.  If multiple control options are installed, the IFT-ECM 

will respond to the last command from the wired wall 

switch, IFT-RC400 or IFT-RC150.  The wired wall 

switch is NOT available if a Power Vent is used.

3.  The Pilot button on the IFT-ECM activates the Cold 

Climate function of the fireplace.  This function lights 

the pilot flame ONLY to provide enough heat in the 

firebox to reduce condensation in cool, high humidity 

ambient conditions.  To activate the Cold Climate 

press and hold the Pilot button for one second and  

release.  The IFT-ECM will flash two green LED blinks, 

 

beep twice and light and rectify the pilot flame when 

 

pressed to activate.  To turn off Cold Climate, press  

and hold the Pilot button for one second and release.   

The IFT-ECM will flash one green LED blink, beep once 

 

and shut down the pilot flame.  If remote controls are 

 

paired with the IFT-ECM, this feature can also be  

activated with the IFT-RC400 and/or IFT-RC150.

The IFT-RC400 and IFT-RC150 remotes are an option 

for the JADE42IN, JADE42IL and JADE32IN models.

CAUTION! 

Risk  of  burns! 

Appliance surfaces are hot 

when  operating  and  during  cool  down.  Use  care  and 

wear gloves when opening the front and accessing com

-

ponents inside the appliance.

Reset Switch Operation 

The control module (IFT-ECM) may lock out under certain 

conditions.  When this occurs, the appliance will not 

ignite or repond to commands and is shut down.  If the 

IFT-ECM is in the LOCK-OUT mode, it will be necessary 

to reset the control module.  

The appliance has a reset switch located inside the 

control cavity.  See Figure 3.6 for approximate location.

To reset the IFT-ECM Control Module:

• Be aware the appliance may be HOT, use 

 

care in accessing the reset switch.

•    Turn the appliance off at a wall switch location if so 

equipped.     

Содержание JADE42IN

Страница 1: ...itter See appliance installation manual for additional Commonwealth of Massachusetts requirements DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS...

Страница 2: ..._____________________________________________ Email _____________________________________________________________ Not Not for use use with with solid solid fuel fuel Ne Ne doit doit pas entre entre ut...

Страница 3: ...Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV Guidelines 8 E Before Lighting Appliance 11 F Lighting...

Страница 4: ...s on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an indepe...

Страница 5: ...RRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishe...

Страница 6: ...INTENDED FOR USE AS A PRIMARY HEAT SOURCE This appliance is tested and approved as either supplemen tal room heat or as a decorative appliance It should not be factored as primary heat in residential...

Страница 7: ...ireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To preven...

Страница 8: ...Wall Surface TV Guidelines NOTICE Temperatures listed above are taken with a temperature measuring probe as prescribed by the test standard used for appliance certification Temperatures on walls or ma...

Страница 9: ...nd from model to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum al...

Страница 10: ...al specifications If the maximum allowable operating temperature for TV is less than 100 degrees Fahrenheit you should not use your TV with this application as damage to your TV may occur Contact the...

Страница 11: ...ve been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that...

Страница 12: ...up plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance if any part has bee...

Страница 13: ...option allows you to bring the warmth from your fireplace to the rest of your home up to 20 feet away Safely place a TV 12 inches above the fireplace The Smart Wall TV Kit must be installed by a qual...

Страница 14: ...Insert four AA cell batteries Battery polarity must be correct or module damage will occur See Figure 3 6 A complete wiring diagram is included in the Electrical section of the appliance Installation...

Страница 15: ...lly pairing a IFT RC400 all installed accessories can be controlled by the IFT RC400 see IFT RC400 user manual The RC150 allows the user to turn ON OFF the flame in the appliance and activate the Cold...

Страница 16: ...appliance See Figure 3 8 Switch is located above the RESET label Hold reset switch down for one second and release A beep will signal module is reset Appliances with Wall Switch and Remote Turn wall s...

Страница 17: ...is gap is designed for positive placement when replacing the glass assembly See Figure 4 1 Clean glass with a non abrasive commercially available cleaner Light deposits Use a soft cloth with soap and...

Страница 18: ...support the glass at all times 3 Verify that the top two glass latches are engaged by vi sually verifying that glass latches have engaged both left and right tabs on the glass frame 4 Verify the bott...

Страница 19: ...l are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Decorative Fronts Surrounds Frequency Annually By Homeowner Tools needed Protective gloves stable work...

Страница 20: ...f the main gas valve opening Inspect for lifting or other flame problems Verify air shutter setting is correct See Installation Manual for required air shutter setting Verify air shutter is clear of d...

Страница 21: ...o see the pilot flame burn continually In an intermittent pilot ignition system IPI the pilot flame should turn off when appliance is turned off Some optional control systems available with IPI models...

Страница 22: ...laced in the path of an air draft or vent Move the remote away from the direct path of air flow The remote acts as the thermostat Flame Modulation The control system is designed to automatically adjus...

Страница 23: ...nnections or electrical shorts in wiring from module to pilot assembly Verify wire insulation is not dam aged Verify wires are not grounding out to chassis pilot burn er or any other metal object Repl...

Страница 24: ...main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes i...

Страница 25: ...ces sories with this appliance Using non listed accessories could result in a safety hazard and will void the warranty Remote Controls Wall Controls and Wall Switches After a qualified service technic...

Страница 26: ...al number when requesting service parts from your dealer or distributor Stocked at depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Non Combustible Support 2492 104 2 Top Fill 2492 135 3 Non Combustible...

Страница 27: ...170 Y 8 3 Grommet SRV2118 420 8 4 Burner Support Left and Right 1 Set 2491 169 8 5 Gasket 2025 407 8 6 Bulkhead W Flex Tube 4021 428 Y 8 7 Valve Bracket 2491 153 8 8 Flex Ball Valve Assembly 12 SRV30...

Страница 28: ...ial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Bronze Media Qty 3 req 2413 850 Exhaust Restrictor 530 299 Gasket Assemb...

Страница 29: ...g service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Header Heat Shield 2118 120 2 Non Combustible Support 2491 104 3 Top Fill 2491 135 4 Non Combus...

Страница 30: ...e 2106 170 Y 9 3 Grommet SRV2118 420 9 4 Burner Support Left and Right 1 Set 2491 169 9 5 Gasket 2025 407 9 6 Bulkhead W Flex Tube 4021 428 Y 9 7 Valve Bracket 2491 153 9 8 Flex Ball Valve Assembly 12...

Страница 31: ...serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER Bronze Media Qty 3 req 2413 850 Exhaust Restrictor 530 299 Gasket As...

Страница 32: ...________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible for use and operati...

Отзывы: