background image

12Majestic • ECHEL36IN-C, ECHEL36STIN-C, ECHEL48IN-C, ECHEL48STIN-C, ECHEL60IN-C, ECHEL72IN-C Owner’s Manual • 2608-981 Rev. B • 7/19

F.  Before Lighting Appliance

Before operating this fireplace for the first time, 

it is rec-

ommended that a qualified service technician

:

•  Verify all shipping materials have been removed from 

inside and/or underneath the firebox.

•  Review proper placement of logs, ember material and/

or other decorative materials.

•  Check the wiring.
•  Check the air shutter adjustment.
•  Ensure that there are no gas leaks.

•  Ensure that the glass is sealed and in the proper position 

and that the integral barrier is in place.

WARNING! 

Risk of Fire or Asphyxiation! 

DO NOT

 op-

erate fireplace with fixed glass assembly removed.

Содержание ECHELON-C Series

Страница 1: ... for use with other gases unless a certified kit is used DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at risk individuals DO NOT store or use gasoline or other flam mable va...

Страница 2: ... Pressure Pression xx x in w c Po Col D eau Maximum Manifold Pressure Pression x x in w c Po Col d eau Minimum Manifold Pressure Pression x x in w c Po Col d eau Minimum rate with variable regulator on control valve Total Electrical Requirements 120Vac 60Hz less than 12 Amperes MADE IN USA USA CANADA ALTITUDE 0 2000 FT 0 4500 FT MAX INPUT BTU h xx xxxx xx xxx MIN INPUT BTU h xx xxx xx xxx ORIFICE ...

Страница 3: ...6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Wall and Mantel Temperatures 8 E Good Faith Wall Surface TV Guidelines 9 F Before Lighting Appliance 12 G Lighting Instructions IPI 13 H Appliance Break In 14 I Heat Management 14 J Operation During A Power Outage 15 K Detailed Component Operating Instruc...

Страница 4: ...D Warranty coverage begins on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless...

Страница 5: ...RRANTY SPECIFIED ABOVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items o...

Страница 6: ...tive appliance It should not be factored as primary heat in residential heating calculations NOTICE This installation must conform with local codes In the absence of local codes you must comply with the National Fuel Gas Code ANSI Z223 1 latest edition in the U S A and the CAN CGA B149 Installation Codes in Canada C BTU Specifications MODEL ECHEL36IN C ECHEL36STIN C ECHEL48IN C ECHEL48STIN C ECHEL...

Страница 7: ... not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To prevent unintended operation when not using your fire place for an extended period of time summer months vacations trips etc Remove batteries from remote controls Turn off wall controls 3 Important Safety and Operating Info...

Страница 8: ... D Wall and Mantel Temperatures ANSI CSA Standards The American National Standards Institute ANSI and Canadian Standards Association CSA write the safety and performance standards to which all gas fireplaces are tested The following are the allowable temperatures around and on a gas fireplace per the ANSI CSA standards Combustible Mantel and Surfaces around a Fireplace The allowable temperature ri...

Страница 9: ... Wall Surface Temperatures Above Appliance with Passive Heat Kit Installed Figure 3 4 Good Faith Wall Surface Temperatures Above Appliance ECHEL60IN C ECHEL72IN C MEASUREMENTS FROM TOP EDGE OF THE OPENING 6 in 18 in 24 in 30 in 36 in 48 in TO CEILING 42 in 12 in 245 F APPLIANCE FRONT 190 F 155 F 140 F 135 F 125 F 125 F FIREPLACE OPENING FACTORY SUPPLIED NON COMBUSTIBLE BOARD SHOWN INSTALLED Figure...

Страница 10: ... 60IN C 36 48STIN C 58 inches ECHEL72IN C Fireplace 2 Since every home has unique air flow characteristics and maximum allowable operating temperatures can vary from manufacturer to manufacturer and from model to model actual TV temperatures should be validated at the time of each installation TVs should not be used in situations where the actual TV temperature exceeds the manufacturers maximum al...

Страница 11: ... top discharge passive heat installations with discharge opening of 3 inches or greater Wire mesh recommended for front discharge or open top discharge passive heat installations with discharge opening of less than three inches Good Faith Guidelines for TV Installations Above a ECHELON C Fireplace with Passive Heat Option Single Sided Appliance Shown ECHEL36IN C 36STIN C 76 1 2 IN MIN ECHEL48IN C ...

Страница 12: ...n Verify all shipping materials have been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper position and that the integral barrier is in place WARNING Risk of Fire or Asphyxiation DO N...

Страница 13: ... s phone Follow the gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance if any part has been under water Immediately call the control system and any gas control which has been under water For use with natural gas and propane A conversion kit as supplied by the manuf...

Страница 14: ... OUT GAS heat management option is available for use with the ECHELON C appliances and is operated with a wall switch The HEAT OUT GAS Kit draws heat from your fireplace and directs it outside up to 25 feet away Optional Passive Heat Kit PH FRT PH SIDE The Passive Heat heat management option is available for use with the ECHELON C appliances The Pas sive Heat Kit allows the heat to be vented into ...

Страница 15: ...he batteries from the battery tray Replace door or decorative barrier front on appliance Ignition Module Slide the ON REMOTE OFF switch to the REMOTE position Remove the batteries from the battery tray Replace decorative barrier front on appliance 3 8 Control Cavity Location CONTROL CAVITY SHOWN IN GRAY BATTERY TRAY CONTROL MODULE IFT ECM CONTROL CAVITY SHOWN IN GRAY 3 9 Battery Tray Location To O...

Страница 16: ...C400 all installed accessories can be controlled by the IFT RC400 see IFT RC400 user manual The IFT ECM has a safety feature that will automatically shut down the fireplace after 9 hours of continuous operation without receiving a command from the IFT RC400 2 If multiple control options are installed the IFT ECM will respond to the last command from the wired wall switch or IFT RC400 The wired wal...

Страница 17: ...under normal circumstances Appliances with Remote Only Turn fireplace back on using the main menu on the remote control The fireplace will ignite as it would under normal circumstances Reinstall bottom glass shield Reinstall decorative barrier front on appliance If the IFT ECM re enters the LOCK OUT condition after this procedure contact your dealer for service CONTROL MODULE IFT ECM SHOWN IN GRAY...

Страница 18: ... hand and secure glass latches with the other hand Assure proper left and right placement of glass and engage all four spring latches Inspect and operate all glass latches to ensure they move freely and no obstructions are present B Maintenance Tasks Homeowner The following tasks may be performed annually by the homeowner If you are uncomfortable performing any of the listed tasks please call your...

Страница 19: ... for proper calibration and setup procedure Place batteries as needed in remote transmitters and battery powered receivers Place remote control out of reach of children If not using your fireplace for an extended period of time summer months vacations trips etc to prevent unin tended operation Remove batteries from remote controls Unplug 6 volt adapter plug on IPI models Venting and Termination Ca...

Страница 20: ... Use caution when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Pilot and Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves vacuum cleaner whisk broom flashlight voltmeter indexed drill bit set and a manometer Inspect or...

Страница 21: ...between appliance models Figure 4 2 IPI Pilot Flame Patterns Electrical Service and Repair WARNING Risk of Shock Label all wires prior to dis connection when servicing controls Wiring errors could cause improper and dangerous operation Verify proper operation after servicing WARNING Risk of Shock Replace damaged wire with type 105º C rated wire Wire must have high temperature insulation ...

Страница 22: ...y also be released from finishing materials and adhesives used around the fireplace These circumstances may require additional curing related to the installation environment Film on the glass This is a normal result of the curing process of the paint and logs Glass should be cleaned within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing pro cess A non abrasiv...

Страница 23: ...ostat Remote is placed in the path of an air draft or vent Move the remote away from the direct path of air flow The remote acts as the thermostat Flame Modulation The control system is designed to automatically adjust the flame intensity based on the difference between the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the act...

Страница 24: ...ition Verify IFT ECM slider switch is in ON or IFT REM position Verify AC power available to junction box Verify AC DC adap tor is plugged into junction box and ECM Verify AC DC adaptor output voltage is between 5 7 6 3 Vdc If battery pack is used check battery pack voltage is 4 2 V if not replace batteries Shorted or loose connection in system wiring or wiring harness Verify system wiring configu...

Страница 25: ...replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red 1 Green Lockout Power Vent PV Failure Power Vent blower defective check wiring to IFT ACM check if blower is working Check if PV pressure switch is connected to brown and black wire in 6 pin valve wire harness Check if pressure switch is closed shorted when PV blower is running Refer t...

Страница 26: ...uded with accessories Contact your dealer for a list of ap proved accessories WARNING Risk of Fire and Electric Shock Use ONLY Hearth Home Technologies approved optional acces sories with this appliance Using non listed accessories could result in a safety hazard and will void the warranty Heat Management Systems The optional heat management systems compatible with this product are discussed in Se...

Страница 27: ...CHEL60IN C ECHEL72IN C Owner s Manual 2608 981 Rev B 7 19 Beginning Manufacturing Date Aug 2019 Ending Manufacturing Date Active Echelon 36 Gas Fireplace DV ECHEL36IN C Service Parts Part number list on following page 07 19 1 2 3 4 6 7 8 9 10 11 12 5 B Service Parts ...

Страница 28: ...e Board Top SRV2312 460 2 Standoff Top Qty 4 req 2602 283 3 Side Trim Qty 2 req 2300 281 4 Non combustible Board Side Qty 2 req 2300 461 5 Bottom Glass 2312 018 6 Burner 2406 007 Y 7 Pilot Assembly See Following Page 8 Shield Pilot 2406 196 9 Glass Assembly GLA 36 MAJ 10 Shield Bottom Glass 2312 179 11 Panel Bottom 2312 147 12 Rock Tray 2406 151 13 LED Light Assembly ALK 36 C 13 1 Power Supply LED...

Страница 29: ... C ECHEL60IN C ECHEL72IN C Owner s Manual 2608 981 Rev B 7 19 Beginning Manufacturing Date Aug 2019 Ending Manufacturing Date Active ECHEL36STIN C Echelon 36 See Through Gas Fireplace DV Service Parts Part number list on following page 1 2 3 4 6 7 8 9 10 11 12 5 ...

Страница 30: ...f Top Qty 4 req 2602 283 3 Side Trim Qty 4 req 2300 281 4 Non combustible Board Side Qty 4 req 2300 461 5 Bottom Glass 2312 018 6 Burner 2406 007 Y 7 Pilot Assembly See Following Page 8 Shield Pilot 2406 196 9 Glass Assembly Qty 2 req GLA 36 MAJ 10 Shield Bottom Glass w vent 2312 179 Shield Bottom Glass 2313 179 11 Panel Bottom w vent 2312 147 Panel Bottom 2313 147 12 Rock Tray 2407 059 13 LED Lig...

Страница 31: ...L48STIN C ECHEL60IN C ECHEL72IN C Owner s Manual 2608 981 Rev B 7 19 Beginning Manufacturing Date Aug 2019 Ending Manufacturing Date Active ECHEL48IN C Echelon 48 Gas Fireplace DV Service Parts Part number list on following page 1 2 3 4 5 6 7 8 9 10 11 12 ...

Страница 32: ...e Board Top SRV2300 460 2 Standoff Top Qty 4 req 2602 283 3 Side Trim Qty 2 req 2300 281 4 Non combustible Board Side Qty 2 req 2300 461 5 Bottom Glass 2300 018 6 Burner 2408 007 Y 7 Pilot Assembly See Following Page 8 Shield Pilot 2406 196 9 Glass Assembly GLA 48 MAJ 10 Shield Bottom Glass 2300 179 11 Panel Bottom 2300 147 12 Rock Tray 2408 151 13 LED Light Assembly ALK 48 C 13 1 Power Supply LED...

Страница 33: ... C ECHEL60IN C ECHEL72IN C Owner s Manual 2608 981 Rev B 7 19 Beginning Manufacturing Date Aug 2019 Ending Manufacturing Date Active ECHEL48STIN C Echelon 48 See Through Gas Fireplace DV Service Parts Part number list on following page 1 2 3 4 5 6 7 8 9 10 11 12 ...

Страница 34: ...f Top Qty 4 req 2602 283 3 Side Trim Qty 4 req 2300 281 4 Non combustible Board Side Qty 4 req 2300 461 5 Bottom Glass 2300 018 6 Burner 2408 007 Y 7 Pilot Assembly See Following Page 8 Shield Pilot 2406 196 9 Glass Assembly Qty 2 req GLA 48 MAJ 10 Shield Bottom Glass w vent 2300 179 Shield Bottom Glass 2301 179 11 Panel Bottom w vent 2300 147 Panel Bottom 2301 147 12 Rock Tray 2409 059 13 LED Lig...

Страница 35: ...L48STIN C ECHEL60IN C ECHEL72IN C Owner s Manual 2608 981 Rev B 7 19 Beginning Manufacturing Date Aug 2019 Ending Manufacturing Date Active Echelon 60 Gas Fireplace DV ECHEL60IN C Service Parts Part number list on following page 1 2 3 4 5 6 7 8 9 10 11 12 ...

Страница 36: ...le Board Top SRV2321 460 2 Standoff Top Qty 4 req 2604 283 3 Side Trim Qty 2 req 2300 281 4 Non combustible Board Side Qty 2 req 2300 461 5 Bottom Glass 2321 018 6 Burner 2410 007 7 Pilot Assembly See Following Page 8 Shield Pilot 2410 196 9 Glass Assembly GLA 60 MAJ 10 Shield Bottom Glass 2321 179 11 Panel Bottom 2321 147 12 Rock Tray 2410 151 13 LED Light Assembly ALK 60 C 13 1 Power Supply LED ...

Страница 37: ...L48STIN C ECHEL60IN C ECHEL72IN C Owner s Manual 2608 981 Rev B 7 19 Beginning Manufacturing Date Aug 2019 Ending Manufacturing Date Active ECHEL72IN C Echelon 72 Gas Fireplace DV Service Parts Part number list on following page 1 3 4 5 6 7 8 9 10 11 12 2 ...

Страница 38: ...DESCRIPTION COMMENTS PART NUMBER 1 Non combustible Board Top SRV2331 460 2 Standoff Top Qty 4 req 2604 283 3 Side Trim Qty 2 req 2300 281 4 Non combustible Board Side Qty 2 req 2300 461 5 Bottom Glass 2331 018 6 Burner 2411 007 7 Pilot Assembly See Following Page 8 Shield Pilot 2410 196 9 Glass Assembly GLA 72 MAJ 10 Shield Bottom Glass 2331 179 11 Panel Bottom 2331 147 12 Rock Tray 2411 151 13 LE...

Страница 39: ...ane Convert 2406 012 with SRV593 527 Y 7 5 Orifice NG 36C ECHEL36IN C 36STIN C 582 836 Y Orifice Propane 52C SRV582 852 Y Orifice NG 124 ECHEL48IN C 48STIN C 582 8124 Y Orifice Propane 50C 582 850 Y Orifice NG 28C ECHEL60IN C 582 828 Y Orifice Propane 49C SRV582 849 Y Orifice NG 23C ECHEL72IN C 582 823 Y Orifice Propane 46C 582 846 Y 14 1 Valve NG 2166 302 Y Valve Propane 2166 303 Y 14 2 Flex Ball...

Страница 40: ...t Burner Neck Seal Cap Air Passage Drawn Air Passage and Flex and Pilot Qty 2 req ECHEL36IN C 2146 413 Y Glass Latch Assembly Qty 4 req ECHEL36STIN C ECHEL48IN C ECHEL60IN C ECHEL72IN C Qty 8 req ECHEL48STIN C Log Assembly Optional ECHEL36IN C 36STIN C LOGS DRTWOOD 36 ECHEL48IN C 48STIN C LOGS DRTWOOD 48 ECHEL60IN C LOGS DRTWOOD 60 ECHEL72IN C LOGS DRTWOOD 72 Light Kit Ambient ECHEL36IN C 36STIN C...

Страница 41: ...8STIN Media Kit Bronze 4 Bags Max GLASS BZ Media Kit Onyx 4 Bags Max GLASS OY Media Kit Saphire 4 Bags Max GLASS SP Media Kit Diamond 4 Bags Max GLASS DM Stones 3 Bags Max STONES NATURAL Media Options ECHEL60IN Media Kit Bronze 6 Bags Max GLASS BZ Media Kit Onyx 6 Bags Max GLASS OY Media Kit Saphire 6 Bags Max GLASS SP Media Kit Diamond 6 Bags Max GLASS DM Stones 3 Bags Max STONES NATURAL Media Op...

Страница 42: ..._________________________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible for use and operation Important operating and maintenance instructions included Read understand and follow these instructions for safe installation and operation Printed in U S A Copyright 2019 ...

Отзывы: