Figure 3.7 Good Faith TV Guidelines - Passive Heat Option
WARNING! Risk of Fire!
Mesh screen required on bottom of discharge opening when discharge
opening is greater than 3 inches. Secure wire mesh to top of framing.
Measurement from top edge
of opening to bottom of
appliance = 24-1/2 IN.
ROOM CEILING
1-1/2 IN. (2 X 4 FRAMING)
2 IN.
TV
12 IN. MIN.
4 IN. MIN.
1/2 IN. X 1/2 IN.
WIRE MESH*
* Wire mesh required for front discharge or open top discharge passive heat installations with discharge
opening of 3 inches or greater.
Wire mesh recommended for front discharge or open top discharge passive heat installations with discharge opening
of less than three inches.
Good Faith Guidelines for TV Installations
Above a ECHELON-C Fireplace with Passive Heat Option
(Single-Sided Appliance Shown)
ECHEL36IN-C/36STIN-C = 76-1/2 IN. MIN.
ECHEL48IN-C/48STIN-C = 76-1/2 IN. MIN.
ECHEL60IN-C = 76-1/2 IN. MIN.
ECHEL72IN-C = 95 IN. MIN.
FIREPLACE
OPENING
2 X 4 FRAMING
2 X 4 OR 2 X 6
FRAMING
CHASE CEILING (REQUIRED)
WIRE MESH*
= PASSIVE HEAT
DISCHARGE OPENING
ECHEL36IN-C/36STIN-C = 48 IN. MIN.
ECHEL48IN-C/48STIN-C = 48 IN. MIN.
ECHEL60IN-C = 48 IN. MIN.
ECHEL72IN-C = 67-1/2 IN. MIN.
1/2 INCH WALL SHEATHING/FINISHING MATERIAL