background image

39

DVBR Series Direct Vent Gas Fireplace

20000584

BASIC WARRANTY

 

CFM Corporation (hereinafter referred to collectively as the Company) 
warrants that your new Vermont Castings

 

or Majestic Gas Fireplace/

Stove is free from manufacturing and material defects for a period of 
one year from the date of purchase, subject to the following conditions 
and limitations.

EXTENDED LIFETIME WARRANTY

 

The  heat  exchanger,  where  applicable,  and  combustion  chamber 
of every Vermont Castings

 or 

Majestic gas product is warranted for 

life against through wall perforation. All appliances equipped with an 
Insta-Flame  Ceramic  Burner  have  limited  lifetime  coverage  on  the 
ceramic burner plaque. Warrantees are made to the original owner 
subject to proof of purchase and the conditions and limitations listed 
on this Warranty Document

COMPONENT WARRANTY

CAST IRON: All external and internal cast iron parts are warranted for a 
period of three years.

 

Note

: On porcelain enamel finished external parts and accessories The 

Company offers no Warranty on chipping of enamel surfaces. Inspect 
all product prior to accepting it for any damage to the enamel.

 

 The salt air environment of coastal areas or a high humidity environment 
can be corrosive to the porcelain enamel finish. These conditions can 
cause rusting of the cast iron beneath the porcelain enamel finish, 
which will cause the finish to flake off.

 

Dye lot variations with replacement parts and/or accessories can occur 
and are not covered by warranty.

GLASS DOORS: Glass doors are covered for a period of one year. 
Glass doors are not warranted for breakage due to misuse or accident.  
Glass doors are not covered for discoloration or burned in stains due to 
environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be 
cleaned with Lemon oil only.

 

Brass cleaners cannot be used.  Mortar 

mix and masonry cleaners may corrode the brass finish.  The Company 
will not be responsible for, nor will it warrant any brass parts which are 
damaged by external chemicals or down draft conditions.
GAS VALVES: Gas valves are covered for a period of one year
ELECTRONIC  AND  MECHANICAL  COMPONENTS:  Electronic  and 
mechanical components of the burner assembly are covered for one year. 
All steel tube burners are warranted for one year.
ACCESSORIES:  Unless  otherwise  noted  all  components  and  CFM 
Corporation company supplied accessories are covered for a period of 
one year.

CONDITIONS AND LIMITATIONS

•  This new Vermont Castings or Majestic product must be installed by 

a competent, authorized, service contractor. A licensed technician, as 
prescribed by the local jurisdiction must perform any installation/service 
work. It must be installed and operated at all times in accordance with 
the Installation and Operating instructions furnished with the product. 
Any alteration, willful abuse, accident, or misuse of the product shall 
nullify this warranty.

•  This warranty is non-transferable, and is made to the original owner, 

provided that the purchase was made through an authorized supplier 
of the Company.

•  The customer must pay for any Authorized Dealer in-home travel fees 

or service charges for in-home repair work. It is the dealers option 
whether the repair work will be done in the customer’s home or in the 
dealer’s shop.

•  If upon inspection, the damage is found to be the fault of the manufacturer, 

repairs will be authorized at no charge to the customer parts and/or 
labor.  

•  Any  part  and/or  component  replaced  under  the  provisions  of  this 

warranty is covered for six months or the remainder of the original 
warranty, whichever is longest.

•  This warranty is limited to the repair of or replacement of part(s) found 

to be defective in material or workmanship, provided that such part(s) 
have been subjected to normal conditions of use and service, after 
said defect is confirmed by the Company’s inspection.

•  The  company  may,  at  its  discretion,  fully  discharge  all  obligations 

with respect to this warranty by refunding the wholesale price of the 
defective part(s)

•  Any installation, labor, construction, transportation, or other related 

costs/expenses  arising  from  defective  part(s),  repair,  replacement, 
or otherwise of same, will not be covered by this warranty, nor shall 
the Company assume responsibility for same. Further, the Company 
will not be responsible for any incidental, indirect, or consequential 
damages except as provided by law.

•  SOME  STATES  DO  NOT  ALLOW  FOR  THE  EXCLUSION  OR 

LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES 
OR  LIMITATIONS  ON  HOW  LONG  AN  IMPLIED  WARRANTY 
LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR 
CIRCUMSTANCES.    THIS  WARRANTY  GIVES  YOU  SPECIFIC 
RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM 
STATE TO STATE. 

•  All other warranties-expressed or implied- with respect to the product, 

its components and accessories, or any obligations/liabilities on the 
part of the Company are hereby expressly excluded.

•  The  Company  neither  assumes,  nor  authorizes  any  third  party  to 

assume on its behalf, any other liabilities with respect to the sale of 
this Vermont Castings or Majestic product

•  The  warranties  as  outlined  within  this  document  do  not  apply  to 

chimney components or other non CFM Corporation accessories used 
in conjunction with the installation of this product..

•  Damage to the unit while in transit is not covered by this warranty but 

is  subject  to  claim  against  the  common  carrier.  Contact  the  dealer 
from whom you purchased your fireplace/stove (do not operate the 
appliance as this might negate the ability to process the claim with the 
carrier).

•  The Company will not be responsible for:

a)  Down drafts or spillage caused by environmental conditions such 

as near-by trees, buildings, roof tops, hills, or mountains.

b)  Inadequate  ventilation  or  negative  air  pressure  caused  by 

mechanical systems such as furnaces, fans, clothes dryers, etc.

•  This warranty is void if:

a)  The fireplace has been operated in atmospheres contaminated by 

chlorine, fluorine, or other damaging chemicals.

b)  The fireplace has been subjected to prolonged periods of dampness 

or condensation

c)  Any damages to the fireplace, combustion chamber, heat exchanger 

or other components due to water, or weather damage, which is the 
result of but not limited to, improper chimney/venting installation.

d)  Any alteration, willful abuse, accident, or misuse of the product 

has occurred.

IF WARRANTY SERVICE IS NEEDED…

1)  Contact your supplier.  Make sure you have your warranty, 

your sales receipt, and the model/serial number of your  
CFM Corporation product.

2)  DO  NOT  ATTEMPT  TO  DO  ANY  SERVICE  WORK 

YOURSELF.

LIMITED LIFETIME WARRANTY 

PRODUCT COVERED BY THIS WARRANTY

All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces 
equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.

Содержание DVBR36

Страница 1: ...rs instructions If you cannot reach your gas supplier call the re department WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PE...

Страница 2: ...f Applications Installation 20 Venting Components 22 Operating Instructions Glass Information 23 Glass Frame Removal 23 Glass Cleaning 23 Replacement of Ceramic Hearth Panels 23 Installation of Logs 2...

Страница 3: ...d not be used as a drying rack for cloth ing nor should Christmas stocking or decorations be hung in the area of it 9 Under no circumstances should any solid fuels wood coal paper or cardboard etc be...

Страница 4: ...ns and framing dimensions Ref DVBR36 DVBR42 A 40 1016 mm 46 1168 mm B 36 614 mm 36 914 mm C 36 914 mm 42 1067 mm D 23 591 mm 24 616 mm E 6 162 mm 6 162 mm F 6 162 mm 5 137 mm G 20 508 mm 20 508 mm H 6...

Страница 5: ...65 mm L 29 749 mm 29 749 mm M 30 768 mm 30 768 mm Framing Dimensions N 40 1029 mm 40 1029 mm O 41 1041 mm 47 1194 mm P 20 521 mm 20 521 mm Q 64 1645 mm 69 1765 mm R 45 1162 mm 49 1245 mm S 32 822 mm 3...

Страница 6: ...e of Combustion Chamber CFM170 Mantel Leg Mantel Leg from Side Ref Depth Ref of Combusion Opening F 14 356 mm K 14 356 mm G 12 305 mm L 12 305 mm H 10 254 mm M 10 254 mm I 8 203 mm N 8 203 mm J 4 102...

Страница 7: ...Pressures Natural LP Minimum Inlet Pressure 5 5 w c 11 0 w c Maximum Inlet Pressure 14 0 w c 14 0 w c Manifold Pressure 3 5 w c 10 0 w c Gas Speci cations Max Min Gas Input Input Model Fuel Control B...

Страница 8: ...ch and install switch into recepta cle box Attach cover plate to switch 3 Connect wiring to gas valve Fig 7 W584 9 WIRING DIAGRAM 1 8 99 djt 11 9 99 added thermopile Thermopile Fig 7 Remote switch wir...

Страница 9: ...e to replace gasket Fig 12 8 Set insulation in back of unit foil side down 9 Secure outer collar adapter to unit with the round collar on top secure with eight 8 screws NOTE Be sure not to damage any...

Страница 10: ...rmination area Location of Vent Termination It is imperative the vent termination be located observ ing the minimum clearances as shown on the following page General Venting DVBR42 1 Remove the seven...

Страница 11: ...assy I Clearance to service regulator vent outlet 3 91cm 3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion air inlet...

Страница 12: ...ent pipe The same proce dure must be performed on the vent side Fig 15 Termination clearances Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible...

Страница 13: ...a vertical line to the bottom of the graph 3 Select the indicated dimension and position the replace in accordance with same EXAMPLE A If the vertical dimension from the oor of the unit is 11 feet 33...

Страница 14: ...necessary to seal this connection If a 45 elbow is being used attach the elbow to the appliance in the same manner then at tach the venting to the elbow It is critical that there is no downward slope...

Страница 15: ...bustion air intake and the ue gas exhaust certain limitations as to vent con gurations apply and must be strictly adhered to The Vent Graph showing the relationship between ver tical and horizontal si...

Страница 16: ...ystem is 270 Fig 30 Example Elbow 1 90 Elbow 2 45 Elbow 3 45 Elbow 4 90 Total angular variation 270 1 2 3 4 1 2 3 4 1 2 3 4 270 FP1180 Fig 30 Maximum elbow usage 3 x 90 Elbows 3 x 90 Elbows FP1176 Fig...

Страница 17: ...nt Opening Non combustible Wall 7 Dia 190mm Fireplace Hearth VO584 100 Fig 31 Locate vent opening on wall Step 3 Place replace into position Measure the vertical height X required from the base of the...

Страница 18: ...ck wall Follow Step 1 and 2 on Page 17 Step 3 Install the four 4 spacer springs on the 4 ex vent pipe When installing the spacer springs around the 4 pipe stretch the spring to approximately 15 381 mm...

Страница 19: ...atertight seal is made around the vent pipe coming through the wall 5 Apply high temperature sealant caulking supplied around the 4 and 7 snorkel collars 6 Slide the snorkel into the vent pipes and se...

Страница 20: ...er height 10 Apply high temperature sealant to 4 and 7 collars of vent termination and install If there is a room above ceiling level restop spacers must be installed on both the bottom and the top si...

Страница 21: ...0000584 Min 2 610 mm FP1185 Fig 45 Minimum termination to roof clearance TWL101a Twist Lock Pipe 2 8 99 djt 3 5 Sheet Metal Screws per Joint Sealant Storm Collar TWL101a Fig 46 Roof ashing 3 5 Sheet M...

Страница 22: ...odel 7TDVP 20 8 24 Starter Pipe Bulk Model 7FDVP 30 8 30 Flex Pipe Bulk 45o Elbow 7TDV45 for Rear Vent to Vertical Vent or Vertical Horizontal Offsets 90o Transition Elbow 7TDVRT90 for Rear Vent to Ve...

Страница 23: ...on the glass It is therefore recommended the glass be cleaned two or three times with a non ammonia household cleaner and warm water gas replace glass cleaner is recommended After initial use glass sh...

Страница 24: ...t Cross Log over the pin of the Right Rear Log and the pin of the Left Log Fig 3 8 DVBR42 only Place the Right Cross Log over the Right Rear Log and the Right Log as shown Fig 53 When positioned corre...

Страница 25: ...ce person Inspecting the Venting System This appliance venting system was designed and constructed to develop a positive ow adequate to remove ue gases to the outside atmosphere Any foreign objects in...

Страница 26: ...26 DVBR Series Direct Vent Gas Fireplace 20000584 Fig 57 Correct ame appearance for DVBR36 model LG389 Fig 58 Correct ame appearance for DVBR42 model LG387...

Страница 27: ...he pilot follow these instruc tions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor...

Страница 28: ...Line Hooked Up Shutoff Valve Open PILOT STAYS LIT For Air In The Lines Thermopile Needs A Min 325mv Adjust Pilot Flame Height All Wiring Connections Replace Thermopile Thermocouple Needs A Min Of 14mv...

Страница 29: ...umper wire accross terminals at wall switch if burner comes on replace defective wall switch If okay jumper wires across wall switch wires at valve if burner comes on wires are faulty or connections a...

Страница 30: ...rt conversion screw supplied in conversion kit in center of HI LO knob Blue for natural gas red for LP 6 Tighten screw replace cap Valve conversion is complete Valve Conversion SIT Valve 1 Using the T...

Страница 31: ...s not necessary to remove the pilot tube for conversion Pilot Conversion PSE 1 Loosen pilot hood turning counterclockwise using a 7 16 end wrench Fig 67 2 Remove pilot ori ce with needlenose pliers Fi...

Страница 32: ...thermopile millivolt gas valve Most of these components may require only an oc casional checkup and cleaning and some may require adjustment If repair is necessary it should be per formed by a quali e...

Страница 33: ...right to make changes in design materials speci cations prices and discontinue colors and products at any time without notice DVBR36 42 Ref Description DVBR36 DVBR42 1 Log Set Complete 20008744 200087...

Страница 34: ...a Pilot Assembly PSE Nat 20000540 20000540 19b Pilot Assembly Nat SIT 10002264 10002264 20 Electrode Ignitor SIT 52465 52465 21 Sensing Electrode 57886 57886 22 Thermocouple RN RP EN EP 53373 53373 23...

Страница 35: ...ox Base Pan Base Pan Hearth Pan Hearth Pan Hearth Support Hearth Support See Detail Detail FK 12 Fan FK 12 Fan Access Cover EB 1 Re ceptacle Fig 72 FK 12 Fan Kit placement 584 10 Top View Side View Re...

Страница 36: ...s A selection of decorative frame trim kits are available for mounting around the outside of the appliance to en hance its visual effect on the room Installation instruc tions for each decorative fram...

Страница 37: ...37 DVBR Series Direct Vent Gas Fireplace 20000584...

Страница 38: ...38 DVBR Series Direct Vent Gas Fireplace 20000584...

Страница 39: ...poninspection thedamageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this w...

Страница 40: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation...