DBT33/DBT36/DBT39 -6-
10002789/0
F
INAL
F
INISHING
Non-combustible materials such as brick or tile may be
extended over the edges of the face of the appliance. DO NOT
cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the brick
or tile will have to be installed flush with the edges of the
appliance.
G
AS
S
PECIFICATIONS
Max.
Min.
Input
Input
Model
Fuel Gas
Control
BTU/h
BTU/h
DBT33RN
Nat.
Millivolt
15,000 10,500
DBT33RP Prop.
Millivolt
15,000 11,250
DBT36RN
Nat.
Millivolt
18,000 12,600
DBT36RP Prop.
Millivolt
18,000 13,500
DBT39RN
Nat.
Millivolt
22,000 15,400
DBT39RP Prop.
Millivolt
22,000 16,500
G
AS
I
NLET
& M
ANIFOLD
P
RESSURES
Fig. 3
Fig. 4
DBT33 / DBT36 / DBT39
CERTIFIED TO
ANSI Z21.88b-1999 / CSA Z2.33b-M99
Vented Gas Fireplace Heaters
Inlet Minimum
Inlet Maximum
Manifold Pressure
Natural Gas
LP (Propane)
4.5" WC
7" WC
3.5" WC
11" WC
13" WC
10" WC
Содержание DBT33
Страница 10: ...DBT33 DBT36 DBT39 10 10002789 0 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15...
Страница 24: ...DBT33 DBT36 DBT39 24 10002789 0 TROUBLE SHOOTING THE GAS CONTROL SYSTEM HONEYWELL MILLIVOLT VALVE...
Страница 28: ...DBT33 DBT36 DBT39 28 10002789 0 PARTS PICTORIAL...
Страница 33: ...10002789 0 33 DBT33 DBT36 DBT39...