6
Majestic • DBDV36PLATIN, DBDV36PLATIL, DBDV42PLATIN, DBDV42PLATIL Owner’s Manual • 2454-981 Rev. C • 3/17
C. BTU Speci
fi
cations
A. Appliance Certi
fi
cation
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
NOTICE:
This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
2
2
Product Speci
fi
c Information
This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
MODELS:
DBDV36PLATIN, DBDV36PLATIL,
DBDV42PLATIN, DBDV42PLATIL
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Direct Vent Heater
STANDARD:
ANSI Z21.88-2014 • CSA 2.33-2014
Models
(U.S. or Canada)
Maximum
Input BTU/h
Minimum
Input BTU/h
Ori
fi
ce
Size
(DMS)
DBDVPLAT36IN
(NG)
(0-2000 FT)
35,000
19,000
33
DBDV36PLATIL
(LP)
(0-2000 FT)
33,000
19,000
51
DBDV42PLATIN
(NG)
(0-2000 FT)
40,000
20,000
31
DBDV42PLATIL
(LP)
(0-2000 FT)
37,000
21,000
50
B. Glass Speci
fi
cations
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
Installation and service of this
appliance should be performed
by quali
fi
ed personnel. Hearth &
Home Technologies recommends
NFI certi
fi
ed professionals.