Your  fireplace  may  also  include  many  of  the  following 

energy efficient components that provide additional heat 

output and efficient home operation:

Heat-Circulation

 adds to the standard radiant heat output 

of a traditional fireplace by distributing useful amounts of 

convective heat into the home. Heat-circulating fireplaces 

circulate cool room air around the hot firebox where it is 

warmed and returned to the room as beneficial heat. The 

BC, BFC, CWC, EWF, SC, WC and WMC Series fireplace 

models feature heat circulation.

The Heat Exchanger

 is a multiple wall construction that 

directs room air around the firebox and back into the room 

of a heat-circulating fireplace system. Heat transfer from 

the hot fire to the circulating room air occurs through these 

passageways. The heat exchanger is the heart of a heat-

circulating system which provides the extra room heat that 

is lost with conventional fireplaces.

The Air Inlet/Outlet Grilles

 are part of the heat-circula-

tion system. Cool room air enters through the bottom grille 

and/or lower side inlet grilles and travels through the heat 

exchanger passageways. The resulting hot air is then re-

turned to the room through the upper outlet grille.

NOTE: Air inlet/outlet grilles should never be covered 

or blocked off. The heat-circulation system is also used 

as fireplace cooling system for safe operation.
Outside  Combustion Air:

 A  fire  requires  a  sufficient 

amount of air in order to burn properly. Insufficient air will 

cause smoking, sooting and harmful gases to filter out of 

the fireplace into the room. As the fire burns in the firebox, 

replacement air enters the firebox opening from the room 

to make up the loss of combustion air. Often tightly sealed 

and well insulated homes do not provide sufficient amounts 

of air for this natural replacement process. To maintain a 

constant flow of combustion air, direct outside air may be 

needed.
Vermont  Castings  Group  fireplaces  are  designed  with 

outside air capabilities which supply outside combustion 

air directly to the firebox. The air system requires ducting 

from fireplace to an outside air source at time of original 

installation. The BC, BR, ODSR, ODWR, SC, SR, STR, 

WBST, WC and WR Series fireplaces offer this feature as 

standard equipment. The BFC fireplace includes integral 

outside air and no additional ducting is necessary.
If your fireplace is equipped with outside air, the control 

lever will be located at the front edge of the left side brick 

on the BC, BR, CWC, ODSR, ODWR, SR, STR, WBST, 

WMC and WR Series. Refer to Page 5 for proper opera-

tion procedure.

Primary Air Control:

 On the EWF Series fireplace, the 

primary air control regulates the amount of heat the fire 

will  produce  and  how  long  it  will  burn. The  primary  air 

control  is  located  in  the  upper  left  corner  of  the  unit.  It 

is the primary source of air for starting, maintaining and 

reviving the fire. 

The air supply is open to the maximum when the control 

lever is rotated clockwise on the EWF36A and closed when 

rotated counterclockwise on the EWF36A. To vary the burn 

rate, adjust the control to the desired position in between 

these extremes; opening the primary air control makes the 

unit burn hotter. Closing the control slows the unit down. 

You can adjust to any position you desire.

Glass  Doors

  improve  fireplace  efficiency  to  help  save 

home energy. When firing a fireplace, the need for combus-

tion air draws room air into the firebox where it mixes with 

the hot flue gases and then is expelled up the open flue. 

The loss of preheated room air is most significant when 

burning a low intensive fire which normally occurs during 

start-up and shutdown of the fireplace. Vermont Castings 

Group glass doors are specially designed to reduce the 

amount of heated room air loss and, at the same time, al-

low the proper amount of combustion air to be filtered into 

the firebox for safe operation.
When using glass doors on a heat-circulating fireplace, 

the controlled combustion air also intensifies the heat ex-

changer temperature and slows the fuel burning rate. The 

result is maximum heating while using the least amount 

of  fuel.  Glass  doors  are  standard  equipment  on  CWC, 

WMC, BFC and EWF Series fireplaces and are offered as 

optional accessories for all other Vermont Castings Group 

fireplace  models.  Refer  to  proper  operation  procedures 

on Page 5.

Forced Air Circulation:

 Heat-circulating fireplaces use the 

natural process of hot air rising to distribute heat from the 

fireplace to the room. This principle is sufficient for small 

room application. To distribute a constant flow of warm air 

further into a larger room, forced air fans are recommended. 

To determine if the fireplace is equipped with fans, use a 

flashlight and look through the lower inlet air grille. Vermont 

Castings Group offers optional fan kits for all heat-circulat-

ing models. For easy installation of an optional fan kit, the 

fireplace should be wired during its installation. Fans are 

standard equipment for CWC, WMC and BFC units.

NOTE: Vermont Castings Group Forced Air Systems 

are designed to distribute heat at a specific cfm rate. 

Any attempt to increase air movement through the heat 

exchanger will decrease the heat transfer time which 

will result in cooler heat circulation temperatures.

Energy  efficient  options  such  as  glass  doors  and  fans 

(Heat-circulating models) can easily be added after your 

original fireplace installation. Refer to Page 12 for descrip-

tion and proper model number.

Содержание BC36

Страница 1: ...sir avec votre foyer bois BC BFC BR CWC EWF ODSR ODWR SC SR STR WBST WC WR and WMC Series Fireplaces Save This Homeowner s Manual Conservez ce manuel du propri taire 20000706 1 13 Rev 16 Foyers S ries...

Страница 2: ...ions 8 Maintenance and Care of Fireplace 9 Troubleshooting Guide 10 Accessories 11 Table of Contents Table des Mati res Faites connaissance avec votre foyer 15 Mode d emploi de votre foyer 17 Mesures...

Страница 3: ...u write the serialization number a series of letters and num bers located below the model number on the warranty card The serial number is stamped into the black plate attached to the inner dome side...

Страница 4: ...the primary air control regulates the amount of heat the fire will produce and how long it will burn The primary air control is located in the upper left corner of the unit It is the primary source of...

Страница 5: ...of the firebox The damper is opened by rotating the lever to the right The damper is closed by pushing the lever to the left and is locked closed by the damper clip located on the dome The damper is...

Страница 6: ...e air operation Fig 4 Log placement on grate MD706 5 Basic Log Set up 1 19 99 MD706 5 replacing the basket grate a specific model must be used Refer to Page 12 for the model number The EWF does not us...

Страница 7: ...eries fireplaces are designed for maximum heat output with doors fully closed at all times NOTE The BFC fireplace should be operated only with the doors fully closed NOTE The EWF fireplace should be o...

Страница 8: ...ogs on end in the corners of the firebox In this position they usually will quickly burn out and will provide good base for your next fire Be sure the firescreen or glass doors are kept closed and the...

Страница 9: ...small 10 Do not overfire your fireplace 11 Always keep the fireplace screens completely closed while the fire is burning 12 Never place any combustible objects furniture pillows etc closer than 24 in...

Страница 10: ...discontinues You may have an obstruction in your flue or debris in or on chimney top Check for obstruction and remove If you fail to inspect your chimney flue as recommended creosote buildup may have...

Страница 11: ...d air items one at a time Watch candle flame If flame is drawn away from the fireplace open an outside door or window If flame returns to upright position these systems are us ing the fireplace system...

Страница 12: ...K8 or S 8 3041130 WR500 42GDKBKSR 203 mm 42GDKDPSR 42GDKSSR ODSR42A AKU1 N A 42GDKBBSR SK8 or S 8 20002230 ODWR500 42GDKBKSR 203 mm 42GDKDBSR 42GDKSSR 42GDKSSSR STR36 AK MST N A 36GDKBB SK8 only 8 205...

Страница 13: ...20000706 13 Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com...

Страница 14: ...14 20000706 Beaucoup de plaisir avec votre foyer bois Foyers S ries BC BR BFC CWC EWF ODSR ODWR SC SR STR WBST WC WR et WMC...

Страница 15: ...z la carte de garantie et postez la Vermont Castings Group Pour valider votre garantie vous devez inscrire sur la carte de garantie le num ro de s rialisation s rie de lettres et de chiffres situ e so...

Страница 16: ...se d un conduit allant du foyer une source d air ext rieur lors de l installation initiale Les foyers des s ries BC BR ODSR ODWR SC SR STR WBST WC et WR comportent ce dispositif standard Une source d...

Страница 17: ...itr es sont ferm es et que la fum e n apparaisse pas dans l aire de combustion Le rendement le plus efficace est obtenu dans la position la moins ouverte Pour r approvisionner en bois ouvrez compl tem...

Страница 18: ...us pouvez sentir une l g re odeur et voir de la fum e provenant de celui ci ou des grilles de refoulement de circulation de chaleur Cela est d la cuisson de la peinture et la combustion 2 Allumage du...

Страница 19: ...le sens des aiguilles d une montre et ferm e quand il est tourn dans l autre sens Pour r gler la combustion ajustez la commande dans la position d sir e entre ces deux points quand la commande d air...

Страница 20: ...limination des cendres Nettoyer les cendres de la chambre de combustion avant d allumer chaque feu Disposez ad quatement des cen dres dans un r cipient m tallique comportant un couvercle herm tique Me...

Страница 21: ...r le registre Mesures de pr caution Bien que les mesures de pr caution suivantes aient t pr sent es plus haut dans ce manuel elles sont indiqu es ici pour insister et fournir une r f rence rapide Mesu...

Страница 22: ...tre inspect e au moins une fois tous les deux 2 mois pendant la saison de chauffage Si une couche important de cr osote s est accumul e celle ci doit tre enlev e pour r duire le risque de feu de chem...

Страница 23: ...e pour soulever le feu au dessus de l tre Cela est important pour obtenir un bon tirage Laissez le feu s teindre et reconstruisez le conform ment aux directives pr c dentes La t te de votre chemin e p...

Страница 24: ...e porte ext rieure ou une fen tre Si la flamme revient en position verticale ces dispositifs utilisent le foyer pour obtenir l air d appoint ce qui provoque les diverses situations d apparition d air...

Страница 25: ...42GDKDP 42GDKS BR42 AK MST S O 42GDKBB SK8 or S 203 mm 3030129 42GDKBK 8 po 42GDKDP 42GDKS SC36A AK MST FK12 36GDKBBSR SK8 or S 203 mm 3041130 WC400 36GDKBKSR 8 po 36GDKDPSR 36GDKSSR SR36A AK MST S O...

Страница 26: ...Du conduit Grille STR36 AK MST S O 36GDKBB SK8 203 mm 2056100 424WBST 36GDKBK seulement 8 po 36GDKDP 36GDKS WMC36 STD STD STD S SK8 203 mm RSBG36 CWC400 8 po WMC42 STD STD STD S 203 mm RSBG36 CWC500 8...

Страница 27: ...20000706 27...

Страница 28: ...28 20000706 Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com...

Отзывы: