75D2525

DVM Series Direct Vent Gas Fireplace

note regardIng Vented products

This product must be installed by a licensed plumber or gas fitter 

when installed within the Commonwealth of Massachusetts.
Any  residence  with  a  direct  vent  product  must  have  a  CO 

detector installed in the residence.
Installation  of  the  fireplace  or  vented  gas  log  in  the  State  of 

Massachusetts requires the damper to be permanently removed 

or welded in the fully open position.
In addition, a naturally vented gas log may not be installed in a 

bedroom or bathroom in the State of Massachusetts.
Flex line installation must not exceed 36 inches and must have 

a T shutoff valve. 

note regardIng Vent free products

This product must be installed by a licensed plumber or gas fitter 

when installed within the Commonwealth of Massachusetts.
In  addition,  vent  free  products  may  not  be  installed  in  a 

bedroom or bathroom regardless of size or type in the State of 

Massachusetts.
Flex line installation must not exceed 36 inches and must have 

a T shutoff valve.

carBon monoxIde detector requIrements

(2) Revise  10.8.3  by  adding  the  following  additional 

requirements:
(a)  

For  all  side  wall  horizontally  vented  gas  fueled 

equipment installed in every dwelling, building or structure used 

in  whole  or  in  part  for  residential  purposes,  including  those 

owned or operated by the Commonwealth and where the side 

wall exhaust vent termination is less than seven (7) feet above 

finished  grade  in  the  area  of  the  venting,  including  but  not 

limited to decks and porches, the following requirements shall 

be satisfied:
1. 

Installation  of  carbon  monoxide  detectors. 

At  the  time 

of  installation  of  the  side  wall  horizontal  vented  gas  fueled 

equipment,  the  installing  plumber  or  gas  fitter  shall  observe 

that a hard wired carbon monoxide detector with an alarm and 

battery  back-up  is  installed  on  the  floor  level  where  the  gas 

equipment is to be installed. In addition, the installing plumber 

or gas fitter shall observe that a battery operated or hard wired 

carbon  monoxide  detector  with  an  alarm  is  installed  on  each 

additional level of the dwelling, building or structure served by 

the side wall horizontal vented gas fueled equipment. It shall be 

the responsibility of the property owner to secure the services of 

qualified licensed professionals for the installation of hard wired 

carbon monoxide detectors
 

a.  In the event that the side wall horizontally vented gas 

fueled equipment is installed in a crawl space or an attic, the 

hard  wired  carbon  monoxide  detector  with  alarm  and  battery 

back-up may be installed on the next adjacent floor level.
 

b.  In the event that the requirements of this subdivision 

can  not  be  met  at  the  time  of  completion  of  installation,  the 

owner shall have a period of thirty (30) days to comply with the 

above requirements; provided, however, that during said thirty 

(30) day period, a battery operated carbon monoxide detector 

with an alarm shall be installed.

massachusetts residents only — please read and follow these special requirements

2. 

approved  carbon  monoxide  detectors.

 

Each  carbon 

monoxide detector as required in accordance with the above 

provisions shall comply with NFPA 720 and be ANSI/UL 2034 

listed and IAS certified.
3. 

signage.

 A  metal  or  plastic  identification  plate  shall  be 

permanently  mounted  to  the  exterior  of  the  building  at  a 

minimum height of eight (8) feet above grade directly in line 

with  the  exhaust  vent  terminal  for  the  horizontally  vented 

gas  fueled  heating  appliance  or  equipment. The  sign  shall 

read,  in  print  size  no  less  than  one-half  (1/2)  inch  in  size, 

“GAS  VENT  DIRECTLY  BELOW.  KEEP  CLEAR  OF  ALL 

OBSTRUCTIONS.”
4. 

Inspection.

 The state or local gas inspector of the side 

wall  horizontally  vented  gas  fueled  equipment  shall  not 

approve the installation unless, upon inspection, the inspector 

observes carbon monoxide detectors and signage installed 

in  accordance  with  the  provisions  of  248  CMR  5.08(2)(a)1 

through 4.
(b) 

exemptions:

  The  following  equipment  is  exempt  from 

248 CMR 5.08(2)(a)1 through 4:
1. The  equipment  listed  in  Chapter  10  entitled  "Equipment 

Not  Required To  Be  Vented"  in  the  most  current  edition  of 

NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled 

equipment installed in a room or structure separate from the 

dwelling,  building  or  structure  used  in  whole  or  in  part  for 

residential purposes.
(c)  

manufacturer requirements — gas equipment Venting 

system  provided.

 

When  the  manufacturer  of  Product 

Approved side wall horizontally vented gas equipment provides 

a venting system design or venting system components with 

the equipment, the instructions provided by the manufacturer 

for installation of the equipment and the venting system shall 

include:
1.  Detailed  instructions  for  the  installation  of  the  venting 

system design or the venting system components; and
2.  A  complete  parts  list  for  the  venting  system  design  or 

venting system.
(d) 

manufacturer  requirements  —  gas  equipment 

Venting system not provided. 

When the manufacturer of 

a Product Approved side wall horizontally vented gas fueled 

equipment  does  not  provide  the  parts  for  venting  the  flue 

gases, but identifies “special venting systems,” the following 

requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall 

be  included  with  the  appliance  or  equipment  installation 

instructions; and
2. The “special venting systems” shall be Product Approved 

by the Board, and the instructions for that system shall include 

a parts list and detailed installation instructions.
(e)  

A copy of all installation instructions for all Product 

Approved side wall horizontally vented gas fueled equipment, 

all venting instructions, all parts lists for venting instructions, 

and/or all venting design

Содержание 500DVM

Страница 1: ...n in manufactured home USA only or mobile home and must be installed in accordance with the manufacturer s instructions and the manufactured home construction and safety standard Title 24 CFR Part 328...

Страница 2: ...lation 25 Fireplace Installation 28 Check Gas Type 28 Gas Pipe Installation 29 Check Gas Pressure Millivolt 30 Electrical Installation Millivolt 30 Electrical Wiring 30 Remote Wall Mounted Switch 31 O...

Страница 3: ...it is not properly installed by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning ar...

Страница 4: ...ese appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada as follows LISTED VENTED GAS FIREPLACE HEATER TEST...

Страница 5: ...RS Switch Ignitor 1 2 Nailing Flange 5 8 Nailing Flange 1 2 Nailing Flange Eyebrow Insulation Board Standoff FP2407 WARNING Do not remove insulation board GAS pressures HIGH ELEVATIONS Input ratings...

Страница 6: ...1067 mm F 32ZB zn 837 mm 38ZB zn 989 mm G 42M zn 1079 mm 42M zn 1079 mm H 34Z x 876 mm 34Z x 876 mm I 23C zn 589 mm 23C zn 589 mm J 34B 880 mm 34B 880 mm K 16Z 410 mm 19Z 486 mm L 14 zn 370 mm 14 zn 3...

Страница 7: ...e Sealant Approved for use with Propane LPG Resistant to sulfur compounds WARNING Do not fill spaces around firebox with insulation or other materials This could cause a fire NOTE COLD CLIMATE INSULAT...

Страница 8: ...o heat from appliance Never obstruct the front opening of the fireplace Do not install in the vicinity where gasoline or other flammable liquids may be stored Vent pipe routing See Venting section fou...

Страница 9: ...m 6 152 mm Min FP2408 DVM MDV clearances 12 305 mm Maximum Depth Ceiling Side Wall Combustible Mantel FP2408 Figure 4 Ceiling and Side Wall Clearances 12 10 8 6 4 256O 12 10 6M 956O 856M 7 6 FP2409 Ma...

Страница 10: ...all and the fireplace surround are sealed a 300 F minimum sealant material General Electric RTV103 or equivalent must be used The fireplace must be secured to the floor and or to framing studs as show...

Страница 11: ...d gasket Figure 7 After conversion to top vent configuration the 5 127 mm flue pipe should be concentric with the 8 203 mm outer collar within 1 4 WARNING FP1991 remove screws Flue Pipe Cover Flue Pip...

Страница 12: ...ps Be aware of electrical wiring locations in walls and ceilings The following actions will void the warranty on your venting system Installation of any damaged venting component Unauthorized modifica...

Страница 13: ...along horizontal length until flue pipe penetrates outside wall A minimum 1 clearance to combustibles permitted all around flue at outside wall WARNING Horizontal sections of this vent system require...

Страница 14: ...walls of your home This is especially important in cold climates Insulation should be considered a combustible material Maintain proper clearances to all combustible materials NOTICE Treatment of fir...

Страница 15: ...bove the meter regulator assembly 5 m above the meter regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliances 1...

Страница 16: ...Figure 13 Rear Wall Venting Graph Horizontal Dimension From the Outside Face of the Wall to the Back of the Fireplace Vertical Dimension From the Floor of Unit to the Center of the Horizontal Vent Pi...

Страница 17: ...ing and termination instructions for further instructions 3 Locate and cut the vent opening in the wall For com bustible walls first frame in opening Combustible Interior Walls Cut a 12Z x H x 10Z x W...

Страница 18: ...able Refer to Page 15 Minimum clearance between vent pipes and combusti ble materials is 3 on top and 1 from bottom and sides unless otherwise noted Exception Outside wall with firestop 1 all around p...

Страница 19: ...calculations and unless specifically mentioned should be ignored when calculating venting layouts FP1176 max 90 bends Figure 20 Maximum Three 3 90 Elbows Per Installation 3 x 90 Elbows 3 x 90 Elbows F...

Страница 20: ...center of the hole should align with the center line of the horizontal rigid vent pipe end Allow 1 4 minimum rise per foot Figure 25 WARNING You may use a reducer from 5 x8 to 4 x6B or 4 x7 for horizo...

Страница 21: ...mately 16 below base of snorkel Install drain pipe Install window well not supplied Refill hole with 12 of coarse gravel leaving a clearance of approximately 4 below snorkel Figure 27 3 Install vent s...

Страница 22: ...e vent system using a maximum of two 90 elbows Figure 30 Up to two 45 elbows may be used within the horizontal run For each 45 elbow used on the horizontal plane the maximum horizontal length must be...

Страница 23: ...1 Maximum Elbow Usage FP1969 offset w wallstrap Figure 32 Offset with Wall Strap and 45 Elbows Roof Flashing Wall Strap 45 Elbows Ceiling Firstop FP1669 Flat ceiling installation 1 Cut a 10Z x 267 mm...

Страница 24: ...ng roof lines steep pitched roofs and other similar factors may cause poor draft or down drafting in high winds Increasing the vent height may solve this problem NOTE If the vent pipe passes through a...

Страница 25: ...uter adapter rings are required to start all flex runs Never install damaged or torn flexible venting Over tightening clamps may rip tear or otherwise damage flexible venting The adapter kit does not...

Страница 26: ...e means to support the flexible vent 5 Flexible vent spacers are to be installed at inter vals prescribed by the flexible vent manufacturer and in such a way as to maintain concentric inner and outer...

Страница 27: ...ove gear clamp 4 x 7 Rigid Pipe Length Flex to Pipe Adapter DVFFA 8 Gear Clamp 1C v Flexible Pipe and Adapter Outer Collar Overlap UL1777 Flex Vent Figure 43 Typical Pipe Connection Gear Clamp FP1976...

Страница 28: ...s not provided A CSA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA design certified equipment shutoff valve from your...

Страница 29: ...em valves We recommend that you install a sediment trap drip leg in supply line as shown in Figure 46 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system betwe...

Страница 30: ...firmly to reseal Do not over torque Check test points for gas leaks NOTE Captured screws for pressure reading are located in the same place in both valve types Millivolt and Electronic Electrical Wir...

Страница 31: ...tend beyond the wall switch wire length provided NOTE Extended lengths of wire may cause the fireplace not to function properly Longer length of wire is permitted if the wire is made out of larger gau...

Страница 32: ...or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to...

Страница 33: ...gnitethepilot Keep knob fully depressed for a few seconds Release and check that pilot continues to burn If the pilot does not stay lit repeat steps 1 and 2 Pilot Position Check for gas leaks in each...

Страница 34: ...the burner to ignite Pilot position Depress and turn knob to pilot position to keep burner off while maintain ing the pilot light Depress and turn knob clockwise to OFF position to turn off gas milli...

Страница 35: ...Electrical Wiring General 1 This fireplace is equipped with the Signature Control valve which operates on 6 volts The 6 volt DC adapter plugs into the fireplace junction box A C power supply Four 4 A...

Страница 36: ...Do not extend beyond the 15 ft wire cable provided If a longer distance is required the 15 ft may be extended up to 30 ft maximum by using two 2 SCSWEK cables plugged together Route the wire from jun...

Страница 37: ...LP Plug in Connector Control Board to Command Center OFF LO LED ON HI Master Switch Command Center Optional Wall Switch Plug in Connector Stepper Motor to Control Board DC Power Green Ground Plug in...

Страница 38: ...d Blower or the control will not work correctly WARNING Electrical connections should only be performed by a qualified licensed electrician Main power supply must be turned off before connecting the f...

Страница 39: ...ol FP2685 BLOTSDV blower wiring OPTIONAL FAN BLOWER SYSTEMS BLOTSDV AUTOMATIC THERMOSTAT BLOWER Figure 53 BLOTSDV Blower Wiring Diagram FP2685 Before installing the blower wire the receptacle into an...

Страница 40: ...r s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will n...

Страница 41: ...mell gas go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame w...

Страница 42: ...ild Proof Lock out X X X X X LCD Backlight X X X X X Security Codes 16 X X X X X Countdown 6 hr Timer X X X Standard Thermostatic Control Mode X X X Smart Mode Thermostat Auto Flame Blower Modulation...

Страница 43: ...nattended You may disable this feature if you wish NOTE By disabling this feature your fireplace may continue to operate unattended 2 When the master switch is in the ON position pressing the ON butto...

Страница 44: ...hen Off 3 Hold the OFF button anytime for three seconds or by turning off the wall switch These two commands of OFF are Memory Off the system will remember all last settings before turning off The nex...

Страница 45: ...ssembly FP2417 Figure 56 Install Canopy FP2418 install canopy Eyebrow Screws FP2418 FP2419 install glass frame Figure 57 Remove Glass Frame Glass Frame Clamps FP2419 CAUTION Each clamp has a quick spr...

Страница 46: ...he rear of the burner on the bracket Fig ure 59 LG665 Rear Log LG667 DVM left middle log Figure 59 Place Rear Log Left Middle Log LG667 3 Place the left middle log by aligning the holes in the bottom...

Страница 47: ...the front right log by setting the notch on the bottom of the log on the very far right tong of the grate and resting the log on the leg of the grate Figure 62 LG670 DVM upper logs Upper Left Log Upp...

Страница 48: ...l with a brush or vacuum WARNING Turn off gas before servicing fireplace It is recommended that a qualified service technician perform these check ups at the beginning of each heating season LG671 DVM...

Страница 49: ...ials may be used Handle glass door with care to avoid striking or scratching it on hard objects To clean glass door follow Glass Removal procedure outlined in the Canopy Installation and Glass Removal...

Страница 50: ...the thermocouple connec tion at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and the other meter le...

Страница 51: ...ust the pilot flame for maximum flame impingement on thermocouple A Check for flue product leak Replace defective pipe section B Check horizontal venting piping is running upward 1 4 per foot Do not r...

Страница 52: ...und Check gas supply Go through Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery vol...

Страница 53: ...56D2135K 56D2263K 4 Glass Frame Assy 1 56D2143K 56D2269K 5 Eyebrow 1 56D4041 56D4038 6 Insulation Board 1 56D2197 56D2216K Accessories Field Installed Options 7 Firebrick Tavern Brown 1 FBMDV500TB FB...

Страница 54: ...54 75D2525 DVM Series Direct Vent Gas Fireplace REPLACEMENT PARTS 1 2C 2I 2T 2 4 5 6 3 8 9 7 10 11 12 13 14 15 16 752525 DVM millivolt parts Standing Pilot Millivolt Control...

Страница 55: ...030 69D0030 69D0030 69D0030 5 Rocker Switch 1 41D0048 41D0048 41D0048 41D0048 6 Piezo Igniter 1 14D0503 14D0503 14D0503 14D0503 7 Injector 1 57D1030 20H3144 56D0614 57D0680 8 Burner Assy 1 75D2509 75D...

Страница 56: ...56 75D2525 DVM Series Direct Vent Gas Fireplace REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM 1 2 3 4 19 5 6 7 8 9 13 14 15 16 17 752523 MDV DVM SC parts 12...

Страница 57: ...0 80D0010 80D0010 80D0010 11 Wire Command Ctr Control Box 2 not shown 1 80D0008 80D0008 80D0008 80D0008 12 A C Adapter 6 Volt 1 80D0041 80D0041 80D0041 80D0041 Accessories 13 Hand Held Remote Control...

Страница 58: ...DVM 1 Rear Log 1 1 75D2016 75D2016 2 Left Middle Log 2 1 75D2017 75D2017 3 Right Middle Log 3 1 75D2018 75D2018 4 Left Front Log 4 1 75D2019 75D2019 5 Right Front Log 5 1 75D2020 75D2020 6 Upper Left...

Страница 59: ...uvers 8 L36PWM L48PWM 3 Screen Frame Black 1 500DVMSD 600DVMSD 4 Cabinet Door Frame Black 1 VSDVC500CDFB VSDVC600CDFB 4 Cabinet Door Frame Iron Age 1 VSDVC500CDFIA VSDVC600CDFIA 4 Cabinet Door w Scree...

Страница 60: ...24 3 6 36 Pipe Length galvanized 46DVA 36 903 4DT 36 4D36 3 6 48 Pipe Length galvanized 46DVA 48 902 4DT 48 4D48 4 6 81 2 Pipe Extension galvanized 46DVA 08A 4DT AJ 4 6 16 Pipe Extension galvanized 46...

Страница 61: ...Length 58DVA 09 1207 5DT 09 3 4 12 Pipe Length 58DVA 12 1206 5DT 12 5D12 3 4 24 Pipe Length 58DVA 24 1204 5DT 24 5D24 3 4 36 Pipe Length 58DVA 36 1203 5DT 36 5D36 3 4 48 Pipe Length 58DVA 48 1202 5DT...

Страница 62: ...stable Vent Length 7TDVP1218 35 64 Adjustable Vent Length 7TDVP3564 8 Vent Pipe 4 pack 7TDVP8 4 12 Vent Pipe 4 pack 7TDVP12 4 24 Vent Pipe 4 pack 7TDVP24 4 36 Vent Pipe 7TDVP36 36 Vent Pipe 30 pack 7T...

Страница 63: ...Pipe 7TDVP36 36 Vent Pipe 30 pack 7TDVP36 30 48 Vent Pipe 7TDVP48 48 Vent Pipe 30 pack 7TDVP48 30 5 x 8 to 4 x 7 Adapter 7TDVP58 Flex Adapter Starter Kit DVFFA 8 Twist Lock Elbows 45 Elbow for Vertica...

Страница 64: ...64 75D2525 DVM Series Direct Vent Gas Fireplace...

Страница 65: ...65 75D2525 DVM Series Direct Vent Gas Fireplace...

Страница 66: ...o comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Pl...

Страница 67: ...e void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect m...

Страница 68: ...09 Recherchez dans la brochure les caract ristique de rendement nerg tique de foyer au gaz nerguide Selon CSA P 4 1 09 Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency 500DVMNV 71 7 50...

Отзывы: