DVB7 Series Direct Vent Gas Fireplace

58

54D7051

Note ReGARDING VeNteD PRoDuCtS

This product must be installed by a licensed plumber or gas fitter 
when installed within the Commonwealth of Massachusetts.
Any  residence  with  a  direct  vent  product  must  have  a  CO 
detector installed in the residence.
Installation  of  the  fireplace  or  vented  gas  log  in  the  State  of 
Massachusetts requires the damper to be permanently removed 
or welded in the fully open position.
In addition, a naturally vented gas log may not be installed in a 
bedroom or bathroom in the State of Massachusetts.
Flex line installation must not exceed 36 inches and must have 
a T shutoff valve. 

Note ReGARDING VeNt FRee PRoDuCtS

This product must be installed by a licensed plumber or gas fitter 
when installed within the Commonwealth of Massachusetts.
In  addition,  vent  free  products  may  not  be  installed  in  a 
bedroom or bathroom regardless of size or type in the State of 
Massachusetts.
Flex line installation must not exceed 36 inches and must have 
a T shutoff valve.

CARBoN MoNoxIDe DeteCtoR RequIReMeNtS

() Revise  10.8.3  by  adding  the  following  additional 
requirements:
(a)  

For  all  side  wall  horizontally  vented  gas  fueled 

equipment installed in every dwelling, building or structure used 
in  whole  or  in  part  for  residential  purposes,  including  those 
owned or operated by the Commonwealth and where the side 
wall exhaust vent termination is less than seven (7) feet above 
finished  grade  in  the  area  of  the  venting,  including  but  not 
limited to decks and porches, the following requirements shall 
be satisfied:
1. 

Installation  of  carbon  monoxide  detectors. 

At  the  time 

of  installation  of  the  side  wall  horizontal  vented  gas  fueled 
equipment,  the  installing  plumber  or  gas  fitter  shall  observe 
that a hard wired carbon monoxide detector with an alarm and 
battery  back-up  is  installed  on  the  floor  level  where  the  gas 
equipment is to be installed. In addition, the installing plumber 
or gas fitter shall observe that a battery operated or hard wired 
carbon  monoxide  detector  with  an  alarm  is  installed  on  each 
additional level of the dwelling, building or structure served by 
the side wall horizontal vented gas fueled equipment. It shall be 
the responsibility of the property owner to secure the services of 
qualified licensed professionals for the installation of hard wired 
carbon monoxide detectors
 

a.  In the event that the side wall horizontally vented gas 

fueled equipment is installed in a crawl space or an attic, the 
hard  wired  carbon  monoxide  detector  with  alarm  and  battery 
back-up may be installed on the next adjacent floor level.
 

b.  In the event that the requirements of this subdivision 

can  not  be  met  at  the  time  of  completion  of  installation,  the 
owner shall have a period of thirty (30) days to comply with the 
above requirements; provided, however, that during said thirty 
(30) day period, a battery operated carbon monoxide detector 
with an alarm shall be installed.

Massachusetts Residents only — Please read and follow these special requirements

Approved  Carbon  Monoxide  Detectors.

 

Each  carbon 

monoxide  detector  as  required  in  accordance  with  the  above 
provisions shall comply with NFPA 70 and be ANSI/UL 034 
listed and IAS certified.
3. 

Signage.

  A  metal  or  plastic  identification  plate  shall  be 

permanently  mounted  to  the  exterior  of  the  building  at  a 
minimum height of eight (8) feet above grade directly in line with 
the exhaust vent terminal for the horizontally vented gas fueled 
heating appliance or equipment. The sign shall read, in print size 
no less than one-half (1/) inch in size, “GAS VENT DIRECTLY 
BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”
4. 

Inspection.

 The state or local gas inspector of the side wall 

horizontally vented gas fueled equipment shall not approve the 
installation  unless,  upon  inspection,  the  inspector  observes 
carbon monoxide detectors and signage installed in accordance 
with the provisions of 48 CMR 5.08()(a)1 through 4.
(b) 

exemptions:

 The following equipment is exempt from 48 

CMR 5.08()(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not 
Required To Be Vented" in the most current edition of NFPA 54 
as adopted by the Board; and
.  Product Approved  side  wall  horizontally  vented  gas  fueled 
equipment  installed  in  a  room  or  structure  separate  from  the 
dwelling,  building  or  structure  used  in  whole  or  in  part  for 
residential purposes.
(c)  

Manufacturer  requirements  —  Gas  equipment  Venting 

System  Provided.

 

When  the  manufacturer  of  Product 

Approved side wall horizontally vented gas equipment provides 
a  venting  system  design  or  venting  system  components  with 
the  equipment,  the  instructions  provided  by  the  manufacturer 
for installation of the equipment and the venting system shall 
include:
1. Detailed instructions for the installation of the venting system 
design or the venting system components; and
. A complete parts list for the venting system design or venting 
system.
(d) 

Manufacturer requirements — Gas equipment Venting 

System  Not  Provided. 

When  the  manufacturer  of  a  Product 

Approved  side  wall  horizontally  vented  gas  fueled  equipment 
does  not  provide  the  parts  for  venting  the  flue  gases,  but 
identifies “special venting systems,” the following requirements 
shall be satisfied by the manufacturer:
1.  The  referenced  "special  venting  system"  instructions  shall 
be  included  with  the  appliance  or  equipment  installation 
instructions; and
. The “special venting systems” shall be Product Approved by 
the Board, and the instructions for that system shall include a 
parts list and detailed installation instructions.
(e)  

A  copy  of  all  installation  instructions  for  all  Product 

Approved side wall horizontally vented gas fueled equipment, 
all  venting  instructions,  all  parts  lists  for  venting  instructions, 
and/or all venting design

Содержание 300DVBNPC7

Страница 1: ...al For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases un...

Страница 2: ...l Wiring Signature Command System 33 Junction Box Wiring 33 Command Center Wall Installation 33 Wall Switch Installation 33 Signature Command Wiring Diagram 34 Optional Fan Blower Systems 35 BLOTSC Signature Command System 35 BLOT Automatic Thermostat Blower 36 FK 12 Manual Blower 36 Operating Instructions Signature Command System 37 Operating Instructions 38 To Turn Off Gas To Appliance 38 Signat...

Страница 3: ...For propane LP fireplace do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors To prevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 3 If you smell gas shut off gas supply do not try to light any appliance do not touch any electrical switch do not use any phone in your building immediately call your gas supplier ...

Страница 4: ...ises during the start up or cool down cycle Similar noises are found with your furnace heat exchanger or car engine IMPORTANT PLEASE READ THE FOLLOWING CAREFULLY It is not unusual for gas fireplaces to give off some odor the first time it is burned This is due to the manufacturing process Please ensure that your room is well ventilated during burn off open all windows It is recommended that you bu...

Страница 5: ...Propane LP Inlet Minimum 4 5 w c 11 0 w c Inlet Maximum 10 5 w c 13 0 w c Manifold Pressure 3 5 w c 10 0 w c Gas Specifications ORIFICE SIZE Max Input Min Input Orifice Model Fuel BTU h BTU h Size 300DVBNV7 Nat 21 000 15 000 43 300DVBPV7 LP 21 000 15 000 54 300DVBNSC7 Nat 21 000 15 000 43 300DVBNPC7 LP 21 000 15 000 54 400DVBNV7 Nat 24 000 17 000 41 400DVBPV7 LP 24 000 17 000 53 400DVBNSC7 Nat 24 ...

Страница 6: ...Z 841 mm 33Z 841 mm K 2Z 54 mm 1Z v 32 mm 1Z v 32 mm 1Z v 32 mm L 1Z x 38 mm 2Z x 64 mm 2Z x 64 mm 2Z x 64 mm M 15 16 24 mm 15 16 24 mm 15 16 24 mm 15 16 24 mm N 31B 803 mm 34C v 883 mm 34C v 883 mm 34C v 883 mm O 33Z x 851 mm 37Z x 953 mm 41Z x 1054 mm 47Z x 1207 mm P 38 966 mm 41B 1057 mm 41B 1057 mm 41B 1057 mm Q 13C v 349 mm 15C v 400 mm 15C v 400 mm 15C v 400 mm R 55ZZ zn 1414 mm 60M 1546 mm ...

Страница 7: ...must be main tained This fireplace may be installed along a wall across a corner or use an exterior chase Refer to Figure 3 for suggested locations Location should be out of high traffic areas and away from furniture and draperies due to heat from appli ance Never obstruct the front opening of the fireplace Do not install in the vicinity where gasoline or other flammable liquids may be stored Vent...

Страница 8: ...e 71 Minimum 11 Minimum 12 Max Min 4 From Either Side Wall FP2248 mantel clearances Figure 4 Clearances Ceiling Combustible Mantel 5 7 11 3 12 8 6 2 FP2204a mantelclearances Wall Stud Standoff FP2204 Top of Exhaust Louvers Side View 1 256O 3 4 156O 256O 45 FP2093A mantel side clearance Wall Combustible Material Area Side of Fire place Opening FP2093a Top View Figure 5 Mantel Clearances mantel clea...

Страница 9: ... for framing or header Framing Nailing Flange Screws Nailing Flange FP2094a Figure 6 Secure Fireplace to Floor and Framing Studs Finishing Material NOTE Any remote wiring i e remote control wall switch and optional fan must be done prior to final finishing to avoid costly reconstruction Only noncombustible materials i e brick tile slate steel or other materials with a UL fire rating of Zero may be...

Страница 10: ...nd gasket Figure 7 WARNING After conversion to top vent configuration the 4 102 mm flue pipe should be concentric within the 6B 175 mm outer collar within 1 4 FP1991 remove screws Screws Flue Pipe Cover Flue Pipe Adapter FP1991 Figure 7 Remove 16 Screws from Flue Pipe Adapter and Flue Pipe Cover FP1992 remove flue pipe Flue Cover Screws Flue Pipe FP1992 Figure 8 Remove Flue Pipe FP1993 attach flue...

Страница 11: ...where rigid direct vent components can be used All restrictions clearances and allowanc es that pertain to the rigid piping apply to the flexible venting Flex kits may not be modified Flex kits may be added to the end of a vent run made of rigid vent sections using pipe manufacturer s approved flex to pipe adapt ers This may occur only if doing so does not violate any of the venting length height ...

Страница 12: ...assembly above the meter regulator assembly 5 m above the meter regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliances 10 000 6 15 cm for appliances to building or the combustion air inlet to any BTU h 3kW 12 30 cm for 10 000 BTU h 3kW 9 other appliances appliances 10 000 BTU h 3kW and 23 cm for appliances 10...

Страница 13: ... minimum of 3 914 mm below the termination cap 3 All gravity air intakes within 3 914 mm of a termination cap must be a minimum of 1 305 mm below the termination cap General Information Assembling Vent Pipes USA Installations The venting system must conform to local codes and or the current National Fuel Code ANSI Z223 1 NFPA 54 Only venting components manufactured by MHSC may be used in Direct Ve...

Страница 14: ... following vent installation instructions to determine the re lationship between the vertical and horizontal dimensions of the vent system 1 Determine the height of the center of the horizontal vent pipe exiting through the outer wall Using this di mension on the Sidewall Vent Graph Figure 14 locate the point intersecting with the slanted graph line 2 From the point of this intersection draw a ver...

Страница 15: ...tside wall A minimum 1 clearance all around the flue is acceptable at this point of penetration If vertical rise is 7Z x feet or higher when top venting the clearance to combustibles is 1 on all sides of the horizontal run Vertical sections of this vent system require a minimum of 1 clearance to combustibles on all sides of the pipe FP2095a vent pipe clearance 3 1 1 3 1 1 3356 841 mm 29 6 753 mm f...

Страница 16: ...ure 17 Noncombustible Walls Hole opening should be 7Z x 191 mm diameter Step 2 Secure firestop to the inside frame center in the 9B x 9B vent opening VO584 100 Vent Opening 2 99 djt Vent Opening for Combustible Walls 9B 244 mm Min Fireplace Hearth Framing Detail Opening for Noncombustible Wall 7Z x 190 mm Fireplace Hearth FP2293 Figure 17 Locate vent opening on wall 9B 244 mm Min Step 3 Measure th...

Страница 17: ...n center ringed flue restrictor must be installed onto the top edge of the firebox flue adapter To create this open center restrictor twist and break off the center rib of the supplied flue restrictor The installed part should appear similar to that show n in Figure 21 Since it is very important that the venting system maintain its balance be tween the combustion air intake and the flue gas ex hau...

Страница 18: ...installation Max 20 36 914 mm Max 36 914 mm Max FP1177 Figure 23 Maximum horizontal run with no rise Example According to the vent graph Page 14 the maximum horizontal vent length in a system with a 7Z x 2 3 m rise is 20 6 m and if a 90 elbow is required in the horizontal vent it must be reduced to 17 5 2 m In Figures 25 26 dimension A plus B must not be great er than 17 5 2m The maximum number of...

Страница 19: ...mm Min Step 2 Secure firestop to the inside frame center in the 9B x 9B vent opening Step 3 Place fireplace into position Measure the vertical height X required from the base of the flue collars to the center of the wall opening Figure 28 Step 4 Using appropriate length of pipe section s attach to fire place with three 3 screws Follow with the installation of the inner and outer elbow again secure...

Страница 20: ...e spring to approximately 15 381 mm wrap the spring around the pipe and interlock the ends of the spacer spring approximately 2 51 mm Measure 6C v 172 mm from the end of the pipe Place the next spring 5 127 mm from the previously installed spring Place the next spring 6 152 mm from the last spring Finally place the last spring 12 305 mm from the last spring installed Figure 30 Step 4 Install the 4...

Страница 21: ... seal is made around the vent pipe coming through the wall 5 Apply high temperature sealant caulking supplied around the 4 and 7 snorkel collars BG402a Top Vent Below grade installation Firestop Screws Minimum 4 Clearance Ground Window Well Gravel Drain Foundation Wall BG402a 24 610 mm Minimum Figure 32 Below Grade Installation Snorkel 7 Pipe 6 Slide the snorkel into the vent pipes and secure to t...

Страница 22: ...top edge of the firebox flue adapter Figure 36 1 Locate your fireplace 2 Plumb to center of the 4 flue collar from ceiling above and mark position 3 Cut opening equal to 9C v x 9C v 248 x 248 mm 4 Proceed to plumb for addi tional openings through the roof In all cases the open ing must provide a mini mum of 1 inch clearance to the vent pipe i e the hole must be at least 9C v x 9C v 248 x 248 mm 5 ...

Страница 23: ...eiling support apps Typical Roof Support Application Typical Ceiling Support Application FP1184 Figure 38 Venting Supports 2 ft Min 2 ft Min X 12 H FP1971 Min chimney clearance Termination Vent Storm Collar Flashing Lowest Discharge Opening Concentric Vent Pipe 1 Minimum Clearance to Combustibles FP1971 Horizontal Overhang Figure 39 Minimum Chimney Clearance Roof Pitch H feet Flat to 6 12 1 0 Over...

Страница 24: ...gn certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA design certified equipment shutoff valve from your dealer For propane LP connections only the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 13 inches of water If yo...

Страница 25: ...f the gas to the fireplace Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess seal ant in pipe could result in clogged burner system valves We recommend that you install a sediment trap drip leg in supply line as shown in Figure 42 Loc...

Страница 26: ...taking pressure reading be sure and turn captured screw clockwise firmly to reseal Do not over torque Check test points for gas leaks Electrical Wiring This fireplace will work without any electrical supply Electricity is only needed to operate blower NOTE If installed in mobile home fireplace must be bolted securely to floor FP1979 Millivolt gas valve FP1979 Figure 43 Gas Pressure Check at Gas Va...

Страница 27: ... the wall switch wire length provided NOTE Extended lengths of wire may cause the fireplace not to function properly Longer length of wire is permitted if the wire is made out of larger gauge diameter wire Always check with local code WARNING Do not connect wall switch to 110 V circuit ON OFF OPTIONAL REMOTE WALL SWITCH ON OFF OPTIONAL REMOTE WALL SWITCH PILOT HI LO ON OFF TH TP TH TP ON OFF RS FP...

Страница 28: ... cover by removing the screw from the left side of the outside firebox wall Junction box was installed at the factory 3 The junction box cover has a factory installed romex style strain relief connector After connect ing the wires route the wire leads through this connector Refer to the wiring diagram in Figure 45 BLACK BLACK WHITE GREEN BLACK BLACK BLACK Receptacle Junction Box 120VAC Optional Th...

Страница 29: ... a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water If you do not follow these instruction exactly a fire or explosion may resul...

Страница 30: ...at period of time when the magnet is closed it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any tools during this operation Damaged knobs may result in serious injury WARNING 1 Depress and turn knob counterclockwise to pilot position 2 Depress fully and hold pilot gas knob Depress piezoigniterasmanytimesasneededtoignitepilot Keep kn...

Страница 31: ...place This switch allows you to turn on and to turn off the main burner without using the gas valve knob Make sure the button is in the ON position to light the main burner Figure 47 Lighting the burner Depress and turn the knob counterclockwise to the ON position Figure 48 It will take less than four 4 seconds for the burner to ignite Pilot position Depress and turn knob to pilot position to keep...

Страница 32: ... leaks General 1 This fireplace is equipped with the Signature Control valve which operates on 6 volts The 6 volt DC adapter plugs into the fireplace junction box A C power supply Four 4 AA batteries are used for back up during power outages 2 The Signature Command System can also be operated without A C power The system can run on four 4 AA batteries for approximately six 6 months under normal us...

Страница 33: ...l Do not extend beyond the 15 ft wire cable provided If a longer distance is required the 15 ft may be extended up to 30 ft maximum by using two 2 SCSWEK cables plugged together Route the wire from junction box to lower control area at bottom of fireplace Unplug the 12 cable from the com mand center Attach the connector to the pins from wire by pushing in to connector making sure to follow the col...

Страница 34: ...ensor Ignitor Sparker Conversion NG LP Plug in Connector Control Board to Command Center OFF LO LED ON HI Master Switch Command Center Optional Wall Switch Plug in Connector Stepper Motor to Control Board DC Power Green Ground Plug in Connector Control Board to Solenoid Gas In Gas Out Pilot Gas Tubing Valve CAUTION Electrical connections should only be performedbyaqualified licensedelectrician Mai...

Страница 35: ...he control will not work correctly WARNING Electrical connections should only be performed by a qualified licensed electrician Main power supply must be turned off before connecting the fan to the main electrical power supply or performing service BLOTSC SIGNATURE COMMAND BLOWER Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection again...

Страница 36: ...2 MANUAL BLOWER 1 This must be done before framing the fireplace When installing the FK 12 blower a wall switch control must be installed to control the blower 2 The fireplace power supply is wired through the blower wall switch and then brought to the fireplace junction box 3 The jumper clip on the plug receptacle must be re moved Figure 56 Use needlenose pliers to break off the jumper clip Junct...

Страница 37: ...e Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not func tion by hand do not try to repair it Call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water ...

Страница 38: ... smell gas go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will light 6 Once pilot flame is established the main burner flame will light automatically 7 If the pilot will not stay lit after several tries turn the master switch to OFF and call your service te...

Страница 39: ...X X X Low battery Indication for Transmitter X X X X X Child Proof Lock out X X X X X LCD Backlight X X X X X Security Codes 16 X X X X X Countdown 6 hr Timer X X X Standard Thermostatic Control Mode X X X Smart Mode Thermostat Auto Flame Blower Modulation X X Three Brightness Settings for Lights X Three Speed Control for Blower X On Off Auxiliary X Programmable Timer to turn blower on and off X B...

Страница 40: ...nattended You may disable this feature if you wish NOTE By disabling this feature your fireplace may continue to operate unattended 2 When the master switch is in the ON position pressing the ON button and the OFF button on the Command Center simultaneously will toggle between enabling and disabling the six hour shutdown op tion 3 After the above operation one beep for enabling the six hour shutdo...

Страница 41: ...w then Off 3 Hold the OFF button anytime for three seconds or by turning off the wall switch These two commands of OFF are Memory Off the system will remember all last settings before turning off The next time the fireplace is turned on all settings will resume To reset change to the desired settings and shut off by using the Memory Off commands and the system will be reset to those new settings C...

Страница 42: ...eplace 3 Set glass frame aside FP2104a BDV remove glass FP2104 Figure 58 Remove Glass Frame Glass Frame Three Tabs Clamps Two 2 on 300 400 Units Three 3 on 500 600 Units WARNING Each clamp has a quick spring force When reinstalling clamps keep fingers clear Remove control panel to operate middle clamp on 500 and 600 units WARNING HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALL...

Страница 43: ... firmly on the two log mounting pins on the bars 2 Place bottom left log 2 on grate Rest the back side of the log in the flat area of the rear log 3 Place bottom right log 3 on grate Rest the back side of the log in the flat area of the rear log 4 Place the top log 4 on the rear log Nest the forked end of the top left log into the fork or the rear log Rest the narrow end of the top on the vertical...

Страница 44: ...her reaching to the main burner burner Inspect area around the injector Remove any lint or foreign material with a brush or vacuum Burner Flame The flames from the burner should be visually checked as soon as the heater is installed and periodically during normal operation In normal operation at full rate and after operating for about 15 to 30 minutes the flame should be yellow and slightly taller...

Страница 45: ...rials may be used Handle glass door with care to avoid striking or scratching it on hard objects To clean glass door follow Glass Removal procedure outlined in the Final Installation section Film deposit on the inside of the glass should be cleaned off using a nontoxic non corrosive non abrasive mild cleaning solution Simply apply an adequate amount to the glass and wipe off with a damp cloth Afte...

Страница 46: ... the thermocouple connec tion at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and the other meter lead wire on the thermocouple copper lead Start the pilot and hold the valve knob in If the millivolt reading is less than 15 mV replace pilot assembly B If thermocouple is producing more than 15 mV re...

Страница 47: ...djust the pilot flame for maximum flame impingement on thermocouple A Check for flue product leak Replace defective pipe section B Check horizontal venting piping is running upward 1 4 per foot Do not run the pipe level or downward C Check for proper installation and freedom from debris or blockage A Install log set per the instructions Inspect the injector and air intake area Make sure this area ...

Страница 48: ...through Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Check valve connections Check power supply go through A E Check grounding Go through B Go through C The sensor on the pilot is not in the flame pilot flame too small ACTION Re install batteries Change ...

Страница 49: ...DVB7 Series Direct Vent Gas Fireplace 54D7051 49 REPLACEMENT PARTS 1 2 3 5 6 7 8 10 4 9 540701 DVB parts FIREBOX COMPONENTS ...

Страница 50: ...3D0006 93D0006 93D0006 Accessories Field Installed Options 2 Brass Louver 1 L30BR L32BR L36BR L42BR 2 Pewter Louver 1 L30PW L32PW L36PW L42PW 5 6 7 Firebrick Walls Cottage Clay 1 FB300CCW FB400CCW FB500CCW FB600CCW 8 Firebrick Floor Cottage Clay 1 FB300CCF FB400CCF FB500CCF FB600CCF 5 6 7 Firebrick Walls Cottage Red 1 FB300CRW FB400CRW FB500CRW FB600CRW 8 Firebrick Floor Cottage Red 1 FB300CRF FB4...

Страница 51: ...DVB7 Series Direct Vent Gas Fireplace 54D7051 51 REPLACEMENT PARTS STANDING PILOT MILLIVOLT CONTROL 1 2C 2I 2T 2 4 5 6 3 8 9 7 10 11 12 13 14 540701 DVB millivolt parts ...

Страница 52: ...3D6046 23D6046 5 Rocker Switch 1 41D0048 41D0048 41D0048 41D0048 41D0048 41D0048 41D0048 41D0048 6 Piezo Igniter 1 14D0503 14D0503 14D0503 14D0503 14D0503 14D0503 14D0503 14D0503 7 Injector 1 62D3006 20H3146 62D3004 20H3143 20H3145 57D0210 20H3145 57D0210 8 Burner Assembly 1 54D0200 54D0200 54D0001 54D0001 54D0001 54D0329 54D0329 54D0329 9 Venturi 1 69D1119 69D1026 69D1119 69D1026 69D1119 69D1026 ...

Страница 53: ...DVB7 Series Direct Vent Gas Fireplace 54D7051 53 REPLACEMENT PARTS 1 2 3 4 20 5 6 7 8 9 13 14 15 16 17 540701 SC parts 12 SIGNATURE COMMAND SYSTEM ...

Страница 54: ...1119 69D1026 69D1119 69D1026 10 Wire Valve Control not shown 1 80D0010 80D0010 80D0010 80D0010 80D0010 80D0010 80D0010 80D0010 11 Wire Command Ctr Control Box 2 1 80D0008 80D0008 80D0008 80D0008 80D0008 80D0008 80D0008 80D0008 not shown 12 A C Adapter 6 Volt 1 80D0041 80D0041 80D0041 80D0041 80D0041 80D0041 80D0041 80D0041 Accessories 13 Hand Held Remote Control w HI LO Timer RMSC 14 Hand Held Rem...

Страница 55: ...2 3 4 540701 DVB log parts Ref Description Qty 300DVB 400DVB 500DVB 600DVB 1 Rear Log 1 1 54D0122 54D0117 54D0331 54D0331 2 Bottom Left Log 2 1 54D0123 54D0118 54D0358 54D0358 3 Bottom Right Log 3 1 54D0124 54D0119 54D0359 54D0359 4 Top Log 4 1 54D0125 54D0120 54D0120 54D0120 ...

Страница 56: ... Vent Pipe 4 pack 7TDVP24 4 36 Vent Pipe 7TDVP36 36 Vent Pipe 30 pack 7TDVP36 30 48 Vent Pipe 7TDVP48 48 Vent Pipe 30 pack 7TDVP48 30 Twist Lock Elbows 45 Elbow for Vertical Horizontal Offset 7TDV45 45 Elbow for Vertical Offsets 8 pack 7TDV45 8 90 Elbow for Vertical Horizontal Offset 7TDV90 90 Elbow for Vertical Horizontal Offset 8 pack 7TDV90 8 Shields and Supports 1 Firestop 7DV1FS 1 Attic Insul...

Страница 57: ...ion w Siding Shield and 2 ea Clamp Bands Twist Lock Pipe 20 Termination Pipe 8 pack 7TDVP20 8 10 16 Adjustable Termination Pipe 4 pack 7TDVPA 4 12 18 Adjustable Vent Length 7TDVP1218 35 64 Adjustable Vent Length 7TDVP3564 8 Vent Pipe 4 pack 7TDVP8 4 12 Vent Pipe 4 pack 7TDVP12 4 24 Vent Pipe 4 pack 7TDVP24 4 36 Vent Pipe 7TDVP36 36 Vent Pipe 30 pack 7TDVP36 30 48 Vent Pipe 7TDVP48 48 Vent Pipe 30 ...

Страница 58: ...comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please read and follow these special requirements 2 Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be A...

Страница 59: ...ted Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of removal reinstallation or transportation of de...

Страница 60: ...DVBPV7 53 8 300DVBNSC7 61 8 300DVBPSC7 55 7 400DVBNV7 58 4 400DVBPV7 58 5 400DVBNSC7 61 1 400DVBPSC7 60 7 500DVBNV7 58 7 500DVBPV7 58 8 500DVBNSC7 61 3 500DVBPSC7 60 8 600DVBNV7 58 4 600DVBPV7 58 5 600DVBNSC7 60 9 600DVBPSC7 60 5 Based on CSA P 4 1 09 Based on CSA P 4 1 09 Recherchez dans la brochure les caractéristique de rendement énergétique de foyer au gaz Énerguide Selon CSA P 4 1 09 ...

Отзывы: