4.  Never install the fireplace 

    •  in a recreational vehicle

    •  where curtains, furniture, clothing, or other flammable 

objects are less than 42" from the front, top, or sides 

of the fireplace

    •  in high traffic areas

    •  in windy or drafty areas 
5.  This fireplace reaches high temperatures. Keep children 

and adults away from hot surfaces to avoid burns or cloth

-

ing ignition. Fireplace will remain hot for a time after 

shutdown. Allow surfaces to cool before touching. 

6.  Carefully supervise young children when they are in the 

room with fireplace. 

7.  Do not modify fireplace under any circumstances. Any 

parts removed for servicing must be replaced prior to 

operating fireplace. 

8.  Turn fireplace off and let cool before servicing, install

-

ing, or repairing. Only a qualified service person should 

install, service, or repair the fireplace. Have burner system 

inspected annually by a qualified service person. 

9.  You must keep control compartments, burners, and cir

-

culating air passages clean. More frequent cleaning may 

be needed due to excessive lint and dust. Turn off the gas 

valve and pilot light before cleaning fireplace. 

10.  Have venting system inspected annually by a qualified 

service person. If needed, have venting system cleaned 

or repaired. See 

Cleaning and Maintenance

, page 39. 

11.  Keep the area around your fireplace clear of combustible 

materials, gasoline, and other flammable vapor and liq

-

uids. Do not run fireplace where these are used or stored. 

Do not place items such as clothing or decorations on or 

around fireplace. 

INSTALLER

Please leave these instructions with the appliance.

OWNER

Please retain these instructions for future reference

.

IMPORTANT SAFETy INFORMATION

This fireplace is a vented product. This fireplace must be 

properly installed by a qualified service person. The glass door 

must be properly seated and sealed. If this unit is not properly 

installed by a qualified service person with glass door properly 

seated and sealed, combustion leakage can occur. 

CARBON  MONOxIDE  POISONING:

 

Early  signs  of 

carbon monoxide poisoning are similar to the flu with head

-

aches, dizziness and/or nausea. If you have these signs, the 

fireplace may not have been installed properly. Get fresh air 

at once! Have the fireplace inspected and serviced by a quali

-

fied service person. Some people are more affected by carbon 

monoxide than others. These include pregnant women, people 

with heart or lung disease or anemia, those under the influence 

of alcohol, and those at high altitudes. 
Propane/LP gas and natural gas are both odorless. An odor-

making agent is added to each of these gases. The odor helps 

you detect a gas leak. However, the odor added to these gases 

can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep 

this manual for reference. It is your guide to safe and proper 

operation of this fireplace.
1.  This appliance is only for use with the type of gas indi

-

cated on the rating plate. This appliance is not convertible 

for use with other gases unless a certified kit is used. 

2.  For propane/LP fireplace, do not place propane/LP supply 

tank(s) inside any structure. Locate propane/LP supply 

tank(s) outdoors. To prevent performance problems, do 

not use propane/LP fuel tank of less than 100 lbs. capac

-

ity. 

3.  If you smell gas

    •  shut off gas supply.

    •  do not try to light any appliance.

    •  do not touch any electrical switch; do not use any 

phone in your building .

    •  immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

Continued on page 4

• Read this owner’s manual carefully and completely before trying to assemble, operate, 

or service this fireplace. 

• Any change to this fireplace or its controls can be dangerous.
• Improper installation or use of this fireplace can cause serious injury or death from 

fire, burns, explosions, electrical shock and carbon monoxide poisoning.

W

ARNING

Содержание 300DVBH

Страница 1: ...l information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not...

Страница 2: ...n 28 Check Gas Type 28 Installing Gas Piping to Fireplace Burner System Location 28 Checking Gas Pressure 30 Electrical Installation 30 Electrical Wiring 30 Remote Wall Mounted Switch 31 Remote Wall S...

Страница 3: ...this unit is not properly installed by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide pois...

Страница 4: ...ll a qualified service person to arrange for replacement of the unit 19 Do not operate fireplace if any log is broken 20 Do not use a blower insert heat exchanger insert or any other accessory not app...

Страница 5: ...y rating determined under continuous operating conditions and was deter mined independently of any installed system Thermal efficiency up to 75 AFUE efficiency up to 71 Hi Lo Knob product SPECIFICATIO...

Страница 6: ...been received You should have the following Fireplace Firebox and Burner System Rock Wool Log Set Items Required For Installation Tools Building Supplies Phillips Screwdriver Framing Materials Hammer...

Страница 7: ...lowing Figure 2 and the chart below for your specific installation requirements See Figure 3 on Page 8 for firebox dimensions The framing headers may rest on the top of the firebox standoffs Do not br...

Страница 8: ...Pipe Rear L R D 161 2 181 2 Rear Width E 28 29 Glass Height F 18 203 8 Total Height G 337 8 405 8 Depth H 15 181 4 Figure 3 Fireplace Dimensions DESCRIPTION Key Letter 300DVBH 400DVBH Height to Stando...

Страница 9: ...and draperies due to heat from appliance Never obstruct the front opening of the fireplace Do not install in the vicinity where gasoline or other flammable liquids may be stored Vent pipe routing See...

Страница 10: ...l flooring the appliance shall be installed on a metal wood or noncombustible material panel extending full width and depth of the appliance WARNING clearances Clearances to combustibles mantel cleara...

Страница 11: ...lace to the floor Use four 4 screws to attach fireplace to framing The side nailing flanges are 1 2 or 5 8 to accommodate different wall thickness SECURING FIREPLACE to floor or framing Figure 6 Secur...

Страница 12: ...Be aware of electrical wiring locations in walls and ceilings The following actions will void the warranty on your venting system Installation of any damaged venting component Unauthorized modificatio...

Страница 13: ...f this vent system require a minimum of 3 clearances to combustibles at the top of the flue and 1 clearance at the sides and bottom until the flue penetrates the outside wall A minimum 1 clearance all...

Страница 14: ...1 Remove the eight 8 screws securing the flue pipe adapter to the fireplace body See Figure 9 2 Set the flue pipe adapter aside complete with the gasket Do not damage the gaskets as the adapter and ga...

Страница 15: ...each floor level If an offset is needed in the attic additional pipe and elbows will be required You may use a chase with a vent termination with exposed pipe on the exterior of the house See Installi...

Страница 16: ...ventilated soffit located above the terminal within a horizontal distance of two 2 feet 610mm from the centerline of the terminal 18 457mm minimum E Clearance to unventilated soffits 12 305mm minimum...

Страница 17: ...he vertical and horizontal dimensions of the vent system 1 Determine the height of the center of the horizontal vent pipe exiting through the outer wall Using this dimension on the Sidewall Vent Graph...

Страница 18: ...r s tabs Attach Simpson s DirectVent Pro by fully inserting into the collar and securing with self tapping screws The screws shall only penetrate the flue outer wall Refer to vent manufacturer s insta...

Страница 19: ...o All Four Sides Vent Cap Wood Screw Cut Vinyl Siding Away to Fit Standoff Wood Screw Simpson Termination 985 Bolt Apply Mastic to All Four Sides Nut Standof 950 Figure 20 Installing Firestop on Horiz...

Страница 20: ...exits through foundations less than 20 below outcrop the termination must be flush up with outcropped wall above It is best to locate the fireplace in such a way that minimizes the number of offsets...

Страница 21: ...n A plus B must not be greater than 17 5 2m The maximum number of 45 elbows permitted per side wall installation is two 2 These elbows can be installed in either the vertical or horizontal run For eac...

Страница 22: ...ase of snorkel Install drain pipe Install window well not supplied Refill hole with 12 of coarse gravel leaving a clearance of approximately 4 below snorkel See Figure 26 3 Install vent system 4 Ensur...

Страница 23: ...y 18 450mm Example Maximum horizontal length No elbows 10 3m 1x45 elbows 8 5 2 6m 2x45 elbows 7 2 1m A minimum of an 8 2 5m vertical rise is required Two sets of 45 elbows offsets may be used within t...

Страница 24: ...e plumb down from the ceiling to the position of the flue exit Mark the center point where the vent will penetrate the ceiling Drill a small locating hole a this point Drop a plumb line from the insid...

Страница 25: ...p roof pitches Nearby trees adjoining roof lines steep pitched roofs and other similar factors may cause poor draft or down drafting in high winds Increasing the vent height may solve this problem NOT...

Страница 26: ...parately UL1777 listed type flex venting only 3 Start the flexible vent as follows A Installing the inner flex adaptor and pipe see Figure 1 1 Insert the long side of the 4 inner ring inte exhaust pip...

Страница 27: ...bed by the flexible vent manufacture and in such a way as to maintain concentric inner and outer vent spacing D Attaching flexible venting to vertical termination assemblies 1 When using Simpson pipe...

Страница 28: ...alling gas piping to fireplace burner system location installation items needed Before installing fireplace and burner system make sure you have the items listed below External regulator supplied by i...

Страница 29: ...ip leg in supply line as shown in Figure 40 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and burner system Locate sediment trap drip...

Страница 30: ...ure reading be sure and turn captured screw clockwise firmly to reseal Do not over torque Check test points for gas leaks Figure 41 Gas Pressure Check at Gas Valve Pressure Test IN Pressure Test OUT H...

Страница 31: ...lways check with local code Figure 42 Wiring Diagram for Wall Switch Do not connect 110V to wall switch WARNING Electrical installation Figure 43 Blower Wiring Diagram Remote Wall Switch Position the...

Страница 32: ...ter firebrick panel on the back wall first Stand firebrick panel straight up against the back of fireplace with the bottom edge at bottom of inner firebox 4 Repeat Step 3 with the left and right side...

Страница 33: ...the unit to establish yellow flame in the front See Figure 46 4 Place log 1 into place by setting the log over the two pins on the grate toward the back The two round holes on the bottom of the logs s...

Страница 34: ...he two notches on the bottom of this log with the two protrusions on log 1 2 This log when seated fits in the middle above logs 1 2 See Figure 50 8 Place log 5 into place by matching the two notches o...

Страница 35: ...bar Figure 52 Placement of Log 6 Figure 53 Placement of Log 7 HBDV400 only Figure 54 a b Andiron Placement 400DVBH and 300DVBH Figure 55 Universal Andirons final installation installing universal and...

Страница 36: ...air may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any par...

Страница 37: ...closed it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any tools during this operation Damaged knobs may result in serious injury WARN...

Страница 38: ...lows you to turn on and to turn off the main burner without using the gas valve knob Make sure the button is in the ON position to light the main burner See Figure 57 Lighting the burner Depress and t...

Страница 39: ...in operation See Figure 61 The pilot flame has three distinct flames one engulfing the thermopile one engulfing the thermocouple and the other reaching to the main burner burner Inspect area around th...

Страница 40: ...Handle glass door with care to avoid striking or scratching it on hard objects To clean glass door follow Glass Removal procedure outlined in the Final Installation section Film deposit on the inside...

Страница 41: ...nection at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and the other meter lead wire on the thermo...

Страница 42: ...for maximum flame impinge ment on thermocouple A Check for flue product leak Replace defective pipe section B Check horizontal venting piping is running upward 1 4 per foot Do not run the pipe level...

Страница 43: ...54D5032 43 1 2 3 5 6 7 10 4 9 11 replacement partS fireplace components...

Страница 44: ...k Right TB 1 54D0285 54D0187 7 Standard Firebrick Left TB 1 54D0285 54D0186 5 Standard Firebrick Center CR 1 26D7097 26D7105 6 Standard Firebrick Right CR 1 26D7096 26D7104 7 Standard Firebrick Left C...

Страница 45: ...54D5032 45 1 2 3 4 5 6 7 11 12 13 14 15 2T 2I 2C 8 8A 400DVBH 8B 300HBDV 10 Millivolt engine replacement partS...

Страница 46: ...03 14D0503 7 Injector 1 62D3006 20H3156 62D3004 33D5039 8 Burner Assembly 1 54D5115 54D5115 54D5006 54D5006 9 Venturi 1 45D0600 45D0600 45D0600 45D0600 10 Wire Assembly 1 44D0500 44D0500 44D0500 44D05...

Страница 47: ...Profile Vertical Termination Cap 46DVA VC 980 4DT VC 1 1 Square Horizontal Termination Cap aluminum 46DVA HC 985 4DT HC Round Horizontal Termination Cap Square Base aluminum 46DVA HRCS Sconce Termina...

Страница 48: ...Description Qty 300DVBH 400DVBH 1 Rear Log 1 54D5125 54D5040 2 Right Log 1 54D5126 54D5041 3 Left Log 1 54D5127 54D5042 4 Mid Top Log 1 54D5129 54D5043 5 Right Top Log 1 54D5128 54D5044 6 Left Front L...

Страница 49: ...feet above finished grade in the area of the venting including but not limited to decks and porches the following requirements shall be satisfied 1 INSTALLATION OF CARBON MONOXIDE DETECTORS At the tim...

Страница 50: ...purposes c MANUFACTURER REQUIREMENTS GAS EQUIPMENTVENTING SYSTEM PROVIDED When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or ven...

Страница 51: ...y will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly dam age by acci...

Страница 52: ...52 54D5032 AUGUST 2008 54D5032 Rev 5 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...