33D4051
17
9"
Minimum
42"
Minimum
9"
Minimum
12"
2 1/2"
10"
19"
CLEARANCES and HEIGHT REQUIREMENTS
Figure 20 - Minimum Mantel Clearances
Canopy
Ensure that minimum clearances shown in
Figures 14 and 15
are maintained. Left and right clearances are determined when
facing the front of the firebox.
Follow these instructions carefully to ensure safe installation. Failure to follow these requirements may create a fire
hazard.
1.
Sidewall Clearances
— The clearance from the inside of the appliance to any combustible adjacent wall should not
be less than 9" for the 24DBXC/24VFSC and 32VFSC.
See Figure 19.
2.
Ceiling Clearance
— The ceiling must be at least 42" from the top of the firebox opening.
See Figures 19 and 20.
3.
Back Wall Clearance
— The appliance may be placed against a combustible back wall.
4.
Floor Clearance
— The fireplace may not be installed onto any combustible flooring material, such as carpeting, vinyl
or tile without the hearth or a min. 22 Ga (0.030") metal or a minimum
1
/
2
" wooden base covering the entire width and
depth of the base. Combustible material must be installed at least 1" away from the front face of the unit.
5.
Mantel clearances
— The canopy supplied with the unit must be installed. If a combustible mantel is installed. It
must meet the clearance requirements detailed in
Figure 20.
Figure 19 - Clearances and Height Requirements for
24VFSC/24DBXC/VFS32
W
ARNING
The dimensions shown in
Figures 19 and 20
are minimum clearances to maintain in
installing this heater. Left and right clearances are determined when facing the front
of the heater.
Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.