33D4051
NATURAL GAS
Manual and T-Stat Pressure
Regulator Pressure Setting 4 in. w.c.
Gas Inlet Pressure:
Max. 10.5 in. w.c.
Min. 5 in. w.c.
PRODUCT FEATURES and SPECIFICATIONS
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Manual control has four (4) positions:
OFF
- All gas to the gas logs is shut off at the valve.
IGN
- Valve position to light/maintain a standing pilot.
ON
-
Valve position to turn ON/OFF log set with remote switch/thermostat.
LOW/HI
-
Variable position to control flame height (heat output). Both front and rear burners are in operation to
provide realistic glow and yellow flame.
Thermostat control has three (3) positions:
OFF
-
All gas to the gas logs is shut off at the valve.
IGN
-
Valve position to light/maintain a standing pilot.
LOW/HI
-
Variable position corresponding to desired temperature.
Continued
Model Number
Type
Gas Rate
Number of
Burners
Max BTU/Hr
Min BTU/Hr
24VFSPMC
Manual
,000
17,000
1
24VFSPVC
Milli-Volt
,000
17,000
1
32VFSPVC
Milli-Volt
6,000
0,000
1
24DBXPTC
T-Stat
10,000
—
1
Milli-Volt Pressure
Regulator Pressure Setting 3.5 in. w.c.
Pilot Regulator
3.5 in. w.c.
Gas Inlet Pressure:
Max. 10.5 in. w.c.
Min. 5 in. w.c.
PROPANE / LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w. c.
T-Stat, Manual and Milli-Volt Pressure
Regulator Pressure Setting
10 in. w.c.
Gas Inlet Pressure:
Maximum 13 in." w.c.
Minimum 11 in. w.c.
Model Number
Type
Gas Rate
Number of
Burners
Max BTU/Hr
Min BTU/Hr
24VFSNMC
Manual
,000
15,000
1
24VFSNVC
Milli-Volt
,000
17,000
1
32VFSNVC
Milli-Volt
6,000
0,000
1
24DBXNTC
T-Stat
10,000
—
1