70D0005

Heater in
Fireplace or
Firebox

8" or More of
Heat Resistant
Material

Hood

TPB Gas Log Set

CLEARANCES and HEIGHT REQUIREMENTS

Figure 6 - 
Measuring Heat Resistant Material for Mantel

Heat resistant material (minimum requirements) with wooden mantel or other combus-
tible projection:

To install the heater with a wooden mantel, shelf or other combustible projection above, first 
measure the heat resistant material shown in 

Figure 6, 

then refer to Table B. 

TABLE B - Heat Resistant Material Heights and Mantel Location

HEAT RESISTANT 

MATERIAL 

MEASUREMENT

REQUIREMENTS FOR SAFE INSTALLATION WITH WOODEN MANTEL, SHELF 

OR OTHER COMBUSTIBLE PROjECTIO

TBP18

TBP24

TBP30

12" or more

Hood not required. Observe 
profiles (side elevations) 
shown in 

Figure 7, page 14.

Hood not required. Observe 
profile (side elevations) shown 
in 

Figure 9, page 1

5

Hood not required. Observe 
profile (side elevations) shown 
in 

Figure 9, page 1

5

8" to less than 12"

Install hood and observe pro-
files shown in 

Figure 8, page 

15

OR

 extend heat resistant 

material to at least 12" and 
observe profiles shown in 

Figure 7, page 14.

Install hood and observe pro-
files shown in 

Figure 7, page 

15

OR 

extend heat resistant 

material to at least 12" and 
observe profiles shown in 

Figure 9, page 15.

Install hood and observe pro-
files shown in 

Figure 7, page 

15

OR 

extend heat resistant 

material to at least 12" and 
observe profiles shown in 

Figure 9, page 15.

Less than 8"

Extend heat resistant mate-
rial to at least 8", install hood 
and observe profiles shown in 

Figure 8, page 15

OR

 extend 

heat resistant material to at 
least 12" and observe profiles 
shown in 

Figure 8, page 14

Extend heat resistant mate-
rial to at least 8", install hood 
and observe profiles shown in 

Figure 7, page 15

OR

 extend 

heat resistant material to at 
least 12" and observe profiles 
shown in 

Figure 9, page 15.

Extend heat resistant mate-
rial to at least 8", install hood 
and observe profiles shown in 

Figure 7, page 15

OR

 extend 

heat resistant material to at 
least 12" and observe profiles 
shown in 

Figure 9, page 15.

Содержание 18TPB

Страница 1: ...as supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier 70D0005...

Страница 2: ...ing System Operation 20 Thank you and congratulations on your purchase of a Gas Log Set PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT Read all instructio...

Страница 3: ...draperies 2 Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition 3 Young children should be carefully supervised wh...

Страница 4: ...pply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 23 Do not use this room h...

Страница 5: ...mended when handling ceramic fiber logs to prevent skin irritation from loose fibers Logs are fragile handle with care Gas Specifications Gas Rate Max Input Min Input Model Fuel Control BTU h BTU h 18...

Страница 6: ...per pa sec m2 or less with openings gasketed or sealed b weather striping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and...

Страница 7: ...91 2001 typically referred to as a Universal Firebox as long as firebox hearth dimen sions meet the minimum hearth dimensions shown below Figure 2 Hearth Minimum Dimension Model A B C D 18TPB 26 13 18...

Страница 8: ...Set in an Enclosure NOTE Non combustible material such as refractory brick may be used to line the floor of the fireplace in order to raise the height of the gas log set in relation to a restrictive...

Страница 9: ...he dimensions shown in Figures 4 through 12 and defined in the fireplace manufacturer s instructions are minimum clearances to maintain when installing this heater Left and right clearances are determ...

Страница 10: ...ter with chimney flue damper open Refer to Installing Vented Applications found on page 18 TABLE A Heat Resistant Material Requirements with no Mantel or Combustible Projection CLEARANCES and HEIGHT R...

Страница 11: ...o less than 12 Install hood and observe pro files shown in Figure 8 page 15 OR extend heat resistant material to at least 12 and observe profiles shown in Figure 7 page 14 Install hood and observe pro...

Страница 12: ...requirements Figure 8 Minimum Mantel Clearance with Hood All Models Example A mantel may project from the wall a maximum of 21 2 at a minimum of 14 above the opening and a maximum of 6 at a minimum of...

Страница 13: ...mantel may project from the wall a maximum of 10 at a minimum of 28 above the opening CLEARANCES and HEIGHT requirements Figure 10 is an example of an unsafe mantel instal lation This mantel projects...

Страница 14: ...is closer than 14 to the base of the fireplace The minimum distance must be maintained from the top surface of carpeting tile etc See Figure 11 OR The gas log heater may be installed nearer to the fl...

Страница 15: ...ot outage or sooting Use a heat resistant seal ant Install and operate the appliance as directed in this manual Damper stop installation A damper stop must be provided with the unit Contact your deale...

Страница 16: ...he grate is essential to prevent any movement of the gas logs and controls during operation Figure 14 Securing Heater to Floor of Fireplace Firebox Screw Anchor Hole Screw WARNING You must secure the...

Страница 17: ...ons that the Pressure Tapping Point May Be Installed CAUTION Use new black iron or steel pipe Internally tinned copper or copper tubing can be used per National Fuel Code section 2 6 3 providing gas m...

Страница 18: ...rn captured screw counter clockwise two or three turns and then place tubing to pressure gauge over test point Use test point OUT closest to control knob After taking pressure reading be sure and turn...

Страница 19: ...ne wire to TH or connect the wall switch thermostat to the two male 0 25 terminals on the left side of the unit The color of the wires does not matter Figure 17 Wiring Diagram Note Log switch wires ar...

Страница 20: ...Reading Thermostat contacts OPEN Main burner OFF 1 Check gas pressure to the unit If gas pressure is within minimum and maximum on data plate then check pilot voltage 500 milli volts minimum If the m...

Страница 21: ...te See Figure 19 2 Place rear log 2 on two pins on back of grate allowing the right end of the rear log to rest on top of the right top log See Figure 20 Pins Rear Log 2 Right Base Log 1 WARNING The p...

Страница 22: ...3 Left Base Log 3 Pins Figure 22 Installing Right Top Log 4 Right top log 4 Pins 4 Place right top log 4 on two pins located to the left of right base log See Figure 22 3 Place left base log 3 on two...

Страница 23: ...PLACEMENT Figure 23 Installing Left Top Log 5 Left Top Log 5 5 Place right end of left top log 5 on bottom center grate pin Rest the left end of left top log 5 on the left base log See Figure 23 Bott...

Страница 24: ...ime size pieces evenly across the burner surface in between the logs Do not add additional Rock Wool See Figure 26 Wash hands after placing Rock Wool Itching may occur Figure 26 Placing Rock Wool Dime...

Страница 25: ...ing Burner on Riser Figure 28 Burner Installed on Riser Important When installing riser kit the minimum recommended height for the fire box opening will be increased by 2 the riser height Steel bar Gr...

Страница 26: ...ure 32 a b Installing Andirons andiron INSTALLATION Optional andirons are available Slide the two tabs in back of each andiron under the cast iron grate The andirons may be used with or without the ri...

Страница 27: ...mocouple then the main burner cannot function reli ably See Figure 34 for incorrect shape of pilot flame Milli volt Control and Thermostat control Figure 33 Correct Appearance of Pilot Flame Figure 34...

Страница 28: ...burning will result During manufacturing fabricating and shipping various components of this appliance are treated with cer tain oils films or bonding agents These chemicals are not harmful but may pr...

Страница 29: ...upplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn...

Страница 30: ...or longer to allow air to bleed out of the gas piping 7 With the control knob pushed in push in and release the piezo ignitor button to light the pilot 8 Continue pushing the control knob in for a fur...

Страница 31: ...p air intake holes clean will result in sooting and poor combustion Inspect and clean all burner ports Inspect ODS pilot for operation and accumulation of lint at air intake holes Verify flame pattern...

Страница 32: ...re 2 Contact local gas company 3 ODS pilot is partially clogged 3 Clean ODS pilot 4 Defective Thermopile 4 Check wire connections Check output should be 500 milli volts across TH TP and TP Terminals w...

Страница 33: ...l gas company 2 Burner orifice is clogged 2 Clean burner or replace burner orifice Slight smoke or odor during initial operation 1 Burner orifice is clogged or damaged 1 Clean burner or replace burner...

Страница 34: ...Log Set replacement parts Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or perso...

Страница 35: ...0468 5 Injector 1 58D0051 58D0052 70D0064 57D0680 70D0064 57D0680 6 ODS Pilot Assy 1 14D0473 14D0477 14D0473 14D0477 14D0473 14D0477 7 On Off Switch 1 32D0232 32D0232 32D0232 32D0232 32D0232 32D0232 8...

Страница 36: ...specifically approved with this appliance may result in property damage or personal injury WARNING Blazing Oak Logs Item Description Qty BOCL18 BOCL24 BOCL30 1 Right Base Log 1 70D0131 70D0041 70D023...

Страница 37: ...37 70D0005 TPB Gas Log Set...

Страница 38: ...ith the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide Massachusetts Residents Only Please read and follow these special requirements dete...

Страница 39: ...he Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burn...

Страница 40: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: