Majestic fireplaces NVBC42 Скачать руководство пользователя страница 10

10

Majestic Fireplaces

®

 NVB Series B-Vent

7412950

EB-1 Electrical Box

The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electrical Code.
For USA installations, follow local codes
and the National Electrical Code, ANSI/
NFPA No. 70.

It is strongly suggested that the wiring of
the EB-1 electrical junction box be car-
ried out by a licensed electrician.

Ensure that the power to the supply line
has been disconnected before commenc-
ing this procedure.

Once the fireplace is secured, complete wiring the fan
kit. Remove knockout in the center of the back of the
EB1 and install listed cable clamps. Feed electrical wire
through cable clamp leaving approximately six (6)
inches of wire exposed through the EB1. Secure cable
clamp to the wire.

Attach white wire from power source to one (1) wire of
receptacle and secure with a nut. Attach black wire from
power source to the other wire of the receptacle and
secure with a nut. Be sure nuts are tightened securely.

Secure the EB1 assembly to the inside of the electrical
box coverplate using two (2) screws. Attach the cover to
the face of the EB1 while being careful to position
excess wire completely within the EB1. Attach the
coverplate to the fireplace. (Fig. 11)

Fig. 11  Junction box (EB-1) hook-up.

FP580

Outside

Electrical Box

Front Of Unit

Inside

Front O

f Unit

 Install the Venting System,

Flashing and Termination

See venting installation instructions provided by the B-
Vent manufacturer.

Refer to Pages 4-5, Figures 1-4 to locate chimney
centerline dimension from a combustible back wall.

• Minimum vertical chimney height — 12 feet (3.65m).

• Maximum vertical height — 40 feet (12m).

• Minimum height with two 90

°

 elbows — 16 feet

(4.06m)

• Elbow requirements allow a maximum of two
90 degree elbows or four 45 degree elbows
per installation. (Two 45 degree elbows =
One 90 degree elbow.) See venting chart for
proper elbow offset runs. Use Table 4 for NVB36/42
installations when not installing the GSKBB Single
Panel Glass Door. Use Table 5 for NVB36/42 instal-
lations when installing the GSKBB Single Panel
Glass Door.

For firestop positioning, refer to Figure 12. Only one (1)
firestop required per frame. NOTE: A firestop is not
required at the roof.

Fig. 12  Firestop/draftstop positions.

Ceiling Installation

Attic Installation

Firestop position when area above ceiling is an attic.

Firestop position when area above ceiling is NOT an attic.

(Firestop/draftstop 
appearances may 
vary. Only 1 firestop 
required per frame.)

Firestop
Spacer

Nails (4)

Joist

FP384

Содержание NVBC42

Страница 1: ...service must be performed by a qualified installer service agency or the gas supplier Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance...

Страница 2: ...to Combustibles 6 Mantels 6 Mantel Chart 6 Hearth 6 Insulating for Cold Climates 6 Framing Finishing 7 Final Finishing 7 Gas Specifications 7 Gas Inlet Manifold Pressures 7 High Elevations 7 Parts Id...

Страница 3: ...lled directly on carpet ing vinyl tile or any combustible material other than wood this appliance must be installed on a metal or wood panel extending the full width and depth of the appliance 12 This...

Страница 4: ...521mm 22 559mm Recessed Nailing Flange 6 DIA Rough Opening Width 41 Rough Opening Depth 3 76mm 1041mm FP562 Fig 2 NVBC36 Series specification and framing dimensions NVBC36 Series Gas Appliance Circul...

Страница 5: ...lectrical Access Gas Line Access Rough Opening Height 16mm 8 213mm 20 508mm 20 521mm 28 711mm Recessed Nailing Flange 6 DIA Rough Opening Width 47 Rough Opening Depth 3 76mm 35 895mm 1194mm FP564 Fig...

Страница 6: ...Opening F 14 356mm K 14 356mm G 12 305mm L 12 305mm H 10 254mm M 10 254mm I 8 203mm N 8 203mm J 1 38mm O 1 38mm Black Surround Face CFM164 CFM170 Fig 5b Combustible mantel leg minimum installation Sid...

Страница 7: ...ivolt Hi Lo 30 000 21 500 NVBR36RP Propane Millivolt Hi Lo 30 000 22 000 NVBC36RP Propane Millivolt Hi Lo 30 000 22 000 NVBR36EN Natural Electronic Ignition 30 000 21 500 NVBC36EN Natural Electronic I...

Страница 8: ...ts individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 45 kPa If gas piping from the so...

Страница 9: ...easily disconnected for burner or fan servicing See gas specification for pressure details and ratings NOTE If flex connector is used it must be kept inside of the appliance Fig 8 FP598 Fig 8 Typical...

Страница 10: ...e of the EB1 while being careful to position excess wire completely within the EB1 Attach the coverplate to the fireplace Fig 11 Fig 11 Junction box EB 1 hook up FP580 Outside Electrical Box Front Of...

Страница 11: ...tem using a maximum of two 45 degree elbows B Acceptable venting configuration Unacceptable venting configuration FP567a Fig 14 Venting configurations when installing 36GSKBB 40 38 36 34 32 30 28 26 2...

Страница 12: ...deposit a slight film on the glass It is therefore recommended that the glass be cleaned two or three times with a non ammonia household cleaner and warm water we recommend gas fireplace glass cleane...

Страница 13: ...ss this moisture disappears in a few minutes of burning Flame Adjustment For units equipped with Hi Lo valves flame adjustment is accomplished by rotating the Hi Lo adjustment knob located near the ce...

Страница 14: ...these instructions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF...

Страница 15: ...the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempting repair may result in a fire or explos...

Страница 16: ...nections Replace Piezo Ignitor Thermodisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple needs a minimum of 14mV...

Страница 17: ...Take protective actions to shield cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check electrical connections between module and gas...

Страница 18: ...ost of these components may require only an occa sional checkup and cleaning and some may require adjustment If repair is necessary it should be per formed by a qualified technician In order to proper...

Страница 19: ...3867 20003909 2 Lava Rock Package 20000376 20000376 3 Bag of Embers 7060109 7060109 4 Burner Housing w Tile 20003791 20003953 5 Ceramic Tile single 57803 57803 6a Burner Orifice Natural Manifold Orifi...

Страница 20: ...ot Assy Natural 4 Way 10002387 10002387 29b E Pilot Assy LP 4 Way 10002388 10002388 30 Sensing Electrodes 57885 57885 31 Ignition Device Honeywell 20000005 20000005 32 Transformer 7522409 7522409 33 A...

Страница 21: ...speed adjustment of the fan Electrical Connection The EB 1 electrical junction box is available for use with the fan kits The EB 1 is standard on the electronic ignition models Glass Doors Bi fold an...

Страница 22: ...c Fireplaces NVB Series B Vent 7412950 Shrouds Decorative shrouds are available to enhance the appearance of the termination cap Square Shroud SSKDKU Pagoda Shroud PSKDKU Bishop Shroud BSKDKU TT Shrou...

Страница 23: ...f upon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provis...

Страница 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com Vermont Castings Majestic Products...

Отзывы: