![Majestic fireplaces FireStage UVHK23RP Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/majestic-fireplaces/firestage-uvhk23rp/firestage-uvhk23rp_installation-and-operating-instructions-manual_696419019.webp)
19
20008055
T100
log notch
on valve cover
10/15/03 djt
Valve
Cover
T100
Fig. 29
Position log so notch fits securely and rests on valve
cover.
T101
secure front log
10/15/03 djt
Front Log
End Bar Should
Fit in V-Shaped
Depression in the
Bark
T101
Fig. 30
Front end of front log should touch grate bar.
T124
Side view
logset
10/28/03 djt
Log Spacer
Bracket
Control
Cover
Rear Log Bracket
T124
All Other
Logsets
Charred Oak
Only
Fig. 31
When using Charred Oak logsets, the rear log spacer
bracket must be cut for the rear log to sit properly.
Troubleshooting
Symptom
Possible Cause
Corrective Action
Indications of poor fuel quality are pilot not staying lit, burners producing abnormal flames and/or soot; unit back-firing when lit.
1. Pilot will not light
a) Air in the line
Bleed the line of air.
b) Low gas pressure
Have gas company check and adjust.
c) Wrong gas type
Have gas company confirm.
2. Insufficient pilot flame
a) Pilot orifice is dirty
Clean the dust/lint from the unit.
b) Drafty around the unit
Eliminate drafts.
3. Burners won’t light
a) Loose or dirty electrical connections
Clean and check the connections
b) Insufficient generator voltage
Replace the pilot assembly.
4. The remote doesn’t work
a) No batteries in the remote or receiver
Install batteries.
b) Dead batteries in remote or receiver
Replace the batteries.
c) Receiver switch in incorrect position
Select the correct position.
d) Remote out of range for receiver
Use the correct range.