background image

27

STR/CVR Series Woodburning Fireplaces

7412961

LIMITED WARRANTY & 30 YEAR PROTECTION PLAN

For MAJESTIC FIREPLACES

®

 PRE-ENGINEERED Fireplace Systems

 

CFM Corporation warrants its MAJESTIC FIREPLACES® 

Pre-Engineered Fireplace (“Fireplace”) and the CFM Corpora-
tion supplied firegrate, glass doors, outside air system, fan mo-
tor, and liners to be free from defects in material or workman-
ship, as follows:

A. Fireplace and Chimney Components:

 (exclusive of CFM 

Corporation-supplied firegrate, glass doors, outside air sys-
tem, fan motor, and liners all of which are covered by separate 
warranties under paragraphs B through D below): At its option 
for a period of thirty (30) years from the date the Fireplace is 
installed, CFM Corporation will;
  (1) For a period of five (5) years from the date the Fireplace 
is installed, CFM Corporation, at its option, will repair or replace 
any defective part without charge.
  (2) Thereafter, through the 10th year after the date the 
Fireplace is installed, if replacement parts are available, CFM 
Corporation will provide a replacement for any defective part 
without charge for the part itself.  The consumer must pay for 
everything else other than the part.
  (3) Thereafter, through the 30th year after the date the 
Fireplace is installed, if replacement parts are available,CFM 
Corporation will provide a replacement for any defective part 
at a cost to the consumer of CFM Corporation then current list 
price, FOB CFM Corporation factory.

B. Firegrate, Glass Doors, Outside Air System:

  For a period of 90 days from the date the Fireplace is 
installed CFM Corporation, at its option, will provide a replace-
ment for any defective part, without charge for the part itself, 
FOB CFM Corporation factory, (The consumer must pay for 
everything else other than the part.).

C. Fan Motor:

  (1) For a period of one (1) year from the date the Fireplace is 
installed, CFM Corporation, at its option, will repair or replace 
any defective part without charge.
  (2) Thereafter, through the 30th year after the date the Fire-
place is installed CFM Corporation, at its option, if replacement 
parts are available, will provide a replacement for any defective 
part at a cost to the consumer of CFM Corporation then current 
list price, FOB CFM Corporation factory.

D. Liners (Refractory or Metal):

  (1) For a period of two (2) years from the date the Fireplace 
is installed, CFM Corporation, at its option, will repair or replace 
any defective part without charge.
  (2) Thereafter, through the 30th year after the date the Fire-
place is installed CFM Corporation, if replacement parts are 
available, will provide a replacement for any defective part at a 
cost to the consumer of CFM Corporation then current list price, 
FOB CFM Corporation factory.
This warranty is subject to the following conditions and limita-
tions:
  (1) This warranty is extended only to a Fireplace installed in 
the continental United States, the state of Alaska and Canada; 
only if and so long as the Fireplace is installed according to 
the installation instructions furnished with the Fireplace, and 

operated at all times under normal conditions, use and service 
according to the operative instructions furnished with the Fire-
place, and only if and so long as the Fireplace is not removed 
from its original installation.
  (2) This warranty is non-transferrable, and is made to the 
original owner, provided that the purchase was made through 
an authorized supplier of the Company.
  (3) The sole and exclusive remedies for breach of any war-
ranties hereunder shall be for the repair, replacement or provi-
sion of a replacement part at CFM Corporation then current list 
price, FOB CFM Corporation  factory, for any defective part as 
specified in paragraphs A through D.
  (4)CFM Corporation shall not be liable for damage from any 
smoking of a MAJESTIC FIREPLACES Pre-Engineered Fire-
place System related to environmental geographic conditions 
(such as, for example, nearby structures or roof peaks, trees, 
hills, or mountains), inadequate ventilation, or negative air 
pressure in the place where the Fireplace system is installed, 
related to any mechanical system (such as, for example, fur-
naces, fans, air conditioners, clothes dryers, etc.)
  (5) Except as otherwise expressly specified in paragraphs 
A through D, NONE OF THESE WARRANTIES COVER, AND  
CFM CORPORATION SHALL NOT BE RESPONSIBLE FOR, 
ANY CONSTRUCTION, INSTALLATION, LABOR, TRANS-
PORTATION OR OTHER COSTS OR EXPENSES ARISING 
FROM A DEFECTIVE PART, ITS REPAIR OR REPLACEMENT 
OR OTHERWISE, NOR SHALL CFM CORPORATION IN ANY 
EVENT BE RESPONSIBLE FOR ANY INDIRECT, INCIDENTAL 
OR CONSEQUENTIAL DAMAGES EXCEPT TO THE EXTENT 
REQUIRED BY LAW.  Some states do not allow the exclusion 
or limitation of incidental or consequential damages, so this 
exclusion or limitation may not apply to you.
  NO IMPLIED WARRANTIES, INCLUDING THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE, SHALL REMAIN IN EFFECT AFTER 
THE EXPIRATION OF THE WARRANTIES SET FORTH IN 
PARAGRAPHS A THROUGH D.  Some states do not allow limi-
tations on how long an implied warranty lasts, so this limitation 
may not apply to you.
  In order to obtain performance of any of the above warranty 
obligations write to CFM Corporation at this address:
   

CFM Corporation

   

2695 Meadowvale Blvd.

   

Mississauga, Ontario, Canada L5N 8A3

   

Attention: Director of Warranty Services

  Since local building requirements may vary greatly through-
out the country, users of CFM Corporation products should 
determine in advance whether there are any building code 
restrictions on the use of a specific product. CFM CORPORA-
TION MAKES NO REPRESENTATION OR WARRANTY RE-
GARDING, AND SHALL NOT BE RESPONSIBLE FOR, ANY 
BUILDING CODE COMPLIANCE.
  The foregoing warranties give you specific legal rights and 
you may also have other rights which vary from state to state.

Содержание CVR36

Страница 1: ...replace For Models STR33 STR36 STR42 CVR36 CVR42 For use in U S Canada Underwriter s Laboratories Report No MH6018 DO NOT DISCARD THIS MANUAL Retain for future use 7412961 3 06 Rev 15 Homeowner s Inst...

Страница 2: ...eplaces replace system notwithstanding any independent testing laboratory or other third party approval of such component parts or accessory Any such action may possibly cause a re hazard Consult loca...

Страница 3: ...3 470mm 508mm 584mm D 49 49 53 1267mm 1267mm 1368mm E 52 52 56 1340mm 1340mm 1442mm F 11 11 13 279mm 279mm 343mm G 8 8 11 203mm 203mm 279mm J 26 29 35 680mm 741mm 894mm Fig 2 CVR Series speci cations...

Страница 4: ...r Standoffs Flue Damper Control Inside Flue Damper Flue Collar Outer Collar Screen Gas Line Knock out Both Sides Brick liner on Sides and Hearth Air Inlet Hearth Wood Grate Firebox Metal Safety Strips...

Страница 5: ...ace and chase parts identi cation FP704 STR from FP528 7 28 98 Termination Cap Storm Collar Pan Flashing Draftstop Finish Wall Batt Insulation cut out around restop Firestop Ceiling Level Outer Dome R...

Страница 6: ...imney exit CVR STR Series Maximum 90 0 Minimum Without Elbows 15 6 With 2 Elbows 17 6 With 4 Elbows 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return top elbow to a stru...

Страница 7: ...from the chimney to the peak of the roof is 10 3m or less the top of the chimney must be at least 2 610mm above the peak of the roof but never less than 3 914mm in height above the highest point where...

Страница 8: ...ON WHEN INSTALLING A FIREPLACE IN AN INSULATED ENCLOSURE BE SURE ALL REQUIRED AIR SPACES ARE MAINTAINED Page 14 Fig 20 Installation Chimney Supports The chimney system is supported by the replace for...

Страница 9: ...on SK8 2 wall chimney systems STR CVR42 Fireplaces use only model 11CF chimney system Straight Up Chimney Installation To locate the centerline of the ue put the replace in nal position and place a pl...

Страница 10: ...evel The following table gives restop spacer model num bers The inside dimension of the frame must be the same as the hole size selected from Figure 12 in order to provide the required air space 1 38m...

Страница 11: ...lace are noncombustible Eight 8 nailing anges are supplied with the replace found on the replace hearth To level the box and secure it rmly in place remove the nailing anges from the hearth and instal...

Страница 12: ...ngled restop spac ers provide minimum required air space to chimney pipe for ceiling thickness up to 8 203mm When combined thickness of ceiling material ceiling joists and ooring material exceeds 8 20...

Страница 13: ...In Canada an attic insulation shield is required to pre vent attic insulation from contacting the chimney sec tion Framing dimensions for the chimney hole should measure 14 x 14 368 x 368mm SK8 An att...

Страница 14: ...required in addition to Firestop Spacers Finishing CAUTION All joints between the nished wall and the replace surround top sides must be sealed with non combustible material to prevent cold air leaka...

Страница 15: ...2 12 305mm Min 12 305mm Max 6 159mm Min FP721 Fig 21 Fireplace surround ush with nished wall Mantel Clearance No Noncombustible Facing Material Finished Wall Standoff 2 x 4 Stud Noncombustible Mate r...

Страница 16: ...26 K 27 1 2 inches thick 2 CFM Corporation EH2416 K 458 1 inch thick required FP723 Fig 23 Minimum rebox dimensions from combustible materials FP723 STR CVR Side Wall clearances 6 21 98 A A B B C C C...

Страница 17: ...Fig 24 Secure the hearth extension to the oor to prevent shifting using trim molding or other similar means at three 3 outer edges Seal crack between the replace hearth and hearth extension with a non...

Страница 18: ...X of listed thickness K of listed material per inch material Example for Common Brick T new 5 0 0 458 x 0 50 in 5 46 in new required thickness Majestic Safety Strips Must be Overlapped 1 2 Min Minimum...

Страница 19: ...NOTE When installing an ANSI Z21 11 2 ventless ap pliance the fninshing material used for the mantel must be rated at 250 F or greater BTU input of a gas appliance installed in replace should be rate...

Страница 20: ...y End 7554342 7554342 5a Screen Assembly Side four per replace 7554338 7554340 5b Screen Assembly End 7554340 7554340 6 Screen Pulls four per replace 5584139 5584139 7a Firebrick Hearth 3102103 310110...

Страница 21: ...Rod Assembly two per replace 3049122 3030126 3032112 5 Screen Assembly four per replace 7554338 7554338 7554340 6 Screen Pulls four per replace 5584139 5584139 5584139 7a Firebrick Hearth 3100103 310...

Страница 22: ...ing accessories for this appliance are available from your local Majestic Fireplaces distributor Should you need additional information beyond what your distributor can furnish contact CFM Corporation...

Страница 23: ...of a square cap Adaptor required Square Termination Top housing with simulated brick pattern T20B Red Tan or Black Proper adapter must be used Includes ashing Adapter Required adapters for T20B top ho...

Страница 24: ...ical SKCS8 SK8 height and 6 of angled chimney run 11CS 11CF U S Chimney Components cont d Model Number Description Component Attic Insulation Shield Used to prevent insulation from coming in AIS SK SK...

Страница 25: ...25 STR CVR Series Woodburning Fireplaces 7412961...

Страница 26: ...26 STR CVR Series Woodburning Fireplaces 7412961...

Страница 27: ...anty is extended only to a Fireplace installed in the continental United States the state of Alaska and Canada only if and so long as the Fireplace is installed according to the installation instructi...

Страница 28: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: