background image

23

CR Series Woodburning Fireplaces

20001316

LIMITED WARRANTY & 30 YEAR PROTECTION PLAN

For MAJESTIC FIREPLACES

®

 PRE-ENGINEERED Fireplace Systems

 

CFM Corporation warrants its MAJESTIC FIREPLACES® 

Pre-Engineered Fireplace (“Fireplace”) and the CFM Corpora-
tion supplied firegrate, glass doors, outside air system, fan 
motor, and liners to be free from defects in material or work-
manship, as follows:

A. Fireplace and Chimney Components:

 (exclusive of CFM 

Corporation-supplied firegrate, glass doors, outside air system, 
fan motor, and liners all of which are covered by separate 
warranties under paragraphs B through D below): At its option 
for a period of thirty (30) years from the date the Fireplace is 
installed, CFM Corporation will;
  (1) For a period of five (5) years from the date the Fireplace 
is installed, CFM Corporation, at its option, will repair or re-
place any defective part without charge.
  (2) Thereafter, through the 10th year after the date the 
Fireplace is installed, if replacement parts are available, CFM 
Corporation will provide a replacement for any defective part 
without charge for the part itself.  The consumer must pay for 
everything else other than the part.
  (3) Thereafter, through the 30th year after the date the 
Fireplace is installed, if replacement parts are available,CFM 
Corporation will provide a replacement for any defective part 
at a cost to the consumer of CFM Corporation then current list 
price, FOB CFM Corporation factory.

B. Firegrate, Glass Doors, Outside Air System:

  For a period of 90 days from the date the Fireplace is 
installed CFM Corporation, at its option, will provide a replace-
ment for any defective part, without charge for the part itself, 
FOB CFM Corporation factory, (The consumer must pay for 
everything else other than the part,).

C. Fan Motor:

  (1) For a period of one (1) year from the date the Fireplace 
is installed, CFM Corporation, at its option, will repair or re-
place any defective part without charge.
  (2) Thereafter, through the 30th year after the date the Fire-
place is installed CFM Corporation, at its option, if replacement 
parts are available, will provide a replacement for any defec-
tive part at a cost to the consumer of CFM Corporation then 
current list price, FOB CFM Corporation factory.

D. Liners (Refractory or Metal):

  (1) For a period of two (2) years from the date the Fireplace 
is installed, CFM Corporation, at its option, will repair or re-
place any defective part without charge.
  (2) Thereafter, through the 30th year after the date the 
Fireplace is installed CFM Corporation, if replacement parts 
are available, will provide a replacement for any defective part 
at a cost to the consumer of CFM Corporation then current list 
price, FOB CFM Corporation factory.
This warranty is subject to the following conditions and limita-
tions:
  (1) This warranty is extended only to a Fireplace installed in 
the continental United States, the state of Alaska and Canada; 
only if and so long as the Fireplace is installed according to 
the installation instructions furnished with the Fireplace, and 

operated at all times under normal conditions, use and service 
according to the operative instructions furnished with the Fire-
place, and only if and so long as the Fireplace is not removed 
from its original installation.
  (2) This warranty is non-transferrable, and is made to the 
original owner, provided that the purchase was made through 
an authorized supplier of the Company.
  (3) The sole and exclusive remedies for breach of any war-
ranties hereunder shall be for the repair, replacement or provi-
sion of a replacement part at CFM Corporation then current list 
price, FOB CFM Corporation  factory, for any defective part as 
specified in paragraphs A through D.
  (4)CFM Corporation shall not be liable for damage from any 
smoking of a MAJESTIC FIREPLACES Pre-Engineered Fire-
place System related to environmental geographic conditions 
(such as, for example, nearby structures or roof peaks, trees, 
hills, or mountains), inadequate ventilation, or negative air 
pressure in the place where the Fireplace system is installed, 
related to any mechanical system (such as, for example, fur-
naces, fans, air conditioners, clothes dryers, etc.)
  (5) Except as otherwise expressly specified in paragraphs 
A through D, NONE OF THESE WARRANTIES COVER, AND  
CFM CORPORATION SHALL NOT BE RESPONSIBLE FOR, 
ANY CONSTRUCTION, INSTALLATION, LABOR, TRANS-
PORTATION OR OTHER COSTS OR EXPENSES ARISING 
FROM A DEFECTIVE PART, ITS REPAIR OR REPLACE-
MENT OR OTHERWISE, NOR SHALL CFM CORPORATION 
IN ANY EVENT BE RESPONSIBLE FOR ANY INDIRECT, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES EXCEPT TO 
THE EXTENT REQUIRED BY LAW.  Some states do not allow 
the exclusion or limitation of incidental or consequential dam-
ages, so this exclusion or limitation may not apply to you.
  NO IMPLIED WARRANTIES, INCLUDING THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR 
A PARTICULAR PURPOSE, SHALL REMAIN IN EFFECT AF-
TER THE EXPIRATION OF THE WARRANTIES SET FORTH 
IN PARAGRAPHS A THROUGH D.  Some states do not allow 
limitations on how long an implied warranty lasts, so this limita-
tion may not apply to you.
  In order to obtain performance of any of the above warranty 
obligations write to CFM Corporation at this address:
   

CFM Corporation

   

2695 Meadowvale Blvd.

   

Mississauga, Ontario, Canada L5N 8A3

   

Attention: Director of Warranty Services

  Since local building requirements may vary greatly through-
out the country, users of CFM Corporation products should 
determine in advance whether there are any building code 
restrictions on the use of a specific product. CFM CORPO-
RATION MAKES NO REPRESENTATION OR WARRANTY 
REGARDING, AND SHALL NOT BE RESPONSIBLE FOR, 
ANY BUILDING CODE COMPLIANCE.
  The foregoing warranties give you specific legal rights and 
you may also have other rights which vary from state to state.

Содержание CR36L

Страница 1: ...ls CR36R CR36L CR Series Corner Woodburning Fireplace DO NOT DISCARD THIS MANUAL Retain for future use For use in U S Canada Underwriter s Laboratories Report No MH6018 20001316 3 06 Rev 13 Homeowner...

Страница 2: ...sembly with a CFM Corporation replace system notwithstanding any independent testing laboratory or other third party approval of such component parts or accessory Any such action may possibly cause a...

Страница 3: ...21 545mm 6 172mm 36 914mm 40 1019mm 41 1054mm Gas Line Access 9 241mm 8 203mm 7 178mm 14 362mm 4 Dia Outside Air Collar Rough Opening Height CR36R L Series Woodburning Fireplace Fig 1 CR36R L Series...

Страница 4: ...n Grate Firebox Outside Air Control Outside Air Cover Plate Gas Access See Figure 20 on page 15 for clearance information Outer Dome Ceiling Level Firestop Batt Insulation cut out around restop Fig 2...

Страница 5: ...himney exit at top CR36L R Series Maximum 90 0 Minimum Without elbows 14 0 With 2 elbows 15 0 With 4 elbows 21 0 B Do not use more than four elbows per chimney Attach the straps of the top elbows to a...

Страница 6: ...on the surface of the roof a distance of 10 3m from the chimney in a horizontal plane The top of the chimney must be at least 2 610mm above the reference point but never less than 3 914mm in height a...

Страница 7: ...ssible Insulate base of replace with a non combus tible insulation rated for a minimum of 300 F Insulating is very important for outside wall installations over a concrete slab If replace is installed...

Страница 8: ...ox and indicate dimension X to locate the side wall framing Fig 8 Be sure to observe clear FP555CR Insulation 2 26 99 djt Hard Flat Surface Insulation Platform FP555CR Fig 7 Insulation between platfor...

Страница 9: ...trip must be fabricated and used to protect combustible surfaces in front of the replace This Z shaped safety strip is not provided but must be fabricated of metal with each horizontal leg at least 1...

Страница 10: ...igure 15 for appro priate spacer orientation Installing the Firestop Spacer in the Ceiling Hole A restop spacer is used to keep pipe spaced properly and required for safety Nail the restop spacer at e...

Страница 11: ...he framing hole Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails Attic shields are not required at the roof Continue Installing Pipe to Complete Ru...

Страница 12: ...predetermined height Check the chimney top installation instructions for details on how high above the roof top the chimney sections all pipes should extend Installing Top Housing or Termination Foll...

Страница 13: ...159mm Min 12 305mm Max 12 305mm Max 7 16 1 1 Fig 18 Fireplace surround ush with nished wall FE101a Combustible Mantel and Trim Mantel Clearance No Noncombustible Facing Material Mantel Clearance with...

Страница 14: ...ille CERAFORM 126 K 27 1 2 thick required 2 CFM Corporation Building Products EH2416 K 458 1 thick required Hearth Installation A hearth extension is required to protect a combustible oor in front of...

Страница 15: ...bustible deco rative covering OR 018 Min Sheet Metal Combustible Floor Minimum Insulation Value R Fireplace Hearth FS108 Sealing Sides 6 22 99 djt Safety Strips must be Overlapped Min Seal Crack Betwe...

Страница 16: ...seal between the pipe and the tube NOTE The gas pipe should not come in contact with any wood structures until it has reached a point at least one 1 inch away from the replace side NOTE Local codes m...

Страница 17: ...83 5a Screen Rod Finished 90 7554156 7554155 5b Screen Rod Finished Straight 7554181 7554181 6 Screen Pulls two per replace 5584139 5584139 7a Firebrick Side 20000793 20000794 7b Firebrick Back 200007...

Страница 18: ...f the system If you use an unapproved component or make any modi cations you may possibly cause a re hazard and will void the CFM Corporation warranty In addition such action may void the coverage pro...

Страница 19: ...alvanized steel unit Roof ashing is included Appropri ate adapter is required See Sections 2 and 3 Required to extend Traditional Top Housings on steeply pitched roofs Used to terminate chimney at the...

Страница 20: ...n the roof Flashing not included For use with CFM Corporation Type SK8 Chimney Systems Used to terminate chimney at the top of a chase Adapter kit included Flashing not included 8 6 12 8 ue 0 to 6 12...

Страница 21: ...25r Adapter kit CTSK42 3 5 99 djt Chase Top Adapter Kit Hearth Patching Kit 325p r P325p Chase top housings SKDSBL PKDSBL 4 28 99 djt Accessories for Canada Accessory Description Model No Attic Insula...

Страница 22: ...22 CR Series Woodburning Fireplaces 20001316...

Страница 23: ...y is extended only to a Fireplace installed in the continental United States the state of Alaska and Canada only if and so long as the Fireplace is installed according to the installation instructions...

Страница 24: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...