Single mode fiber optic line:8.3/125, 837/125, 9/125, 10/125um
◆
MT8110 product type and each type parameters
Twist-Pair
Communication
distance
Sent
wave
nm
Receive
wave
nm
transmitted
power
dBm
Receiver
sensitivity
dBm
light
saturation
dBm
Power
loss
dB/km
Multimode -2km
850
850
−10~−3
≤−24
≥−9
4
Multimode -2km
1310
1310
−22~-12
≤−30
≥−3
2
Singlemode -25km
1310
1310
−15~−8
≤−36
≥0
0.35
Singlemode -40km
1310
1310
−8~-3
≤−38
≥0
0.35
Singlemode -60km
1310
1310
−3~0
≤−38
≥0
0.35
Singlemode -80km
1550
1550
−5~0
≤−38
≥0
0.25
Singlemode -100km 1550
1550
≥-1
≤−38
≥0
0.25
Single fiber bi-directional
Communication
distance
Sent
wave
nm
Receive
wave nm
transmitted
power
dBm
Receiver
sensitivity
dBm
light
saturation
dBm
Power
loss
dB/km
Singlemode -25km
1310
1550
−
15~
−
8
≤
−36
≥
0
0.35
Singlemode -25km
1550
1310
−
8~-3
≤
−36
≥
0
0.25
Singlemode -40km
1310
1550
−
3~0
≤
−36
≥
0
0.35
Singlemode -40km
1550
1310
−
5~0
≤
−38
≥
0
0.25
Singlemode -60km
1310
1550
−
3~0
≤
−38
≥
0
0.35
Singlemode -60km
1550
1310
−
3~0
≤
−38
≥
0
0.25
◆
Maintain and Service
MT8110
has 5 years’ guarantee. According to the Product Specifications of
Maiwe, we will maintain or change the product for free which has any problem in
this guarantee, of that is not including the destroy of error usage, accident,
natural disaster and incorrect installation.
To ensure the customer’s profit, we also provide some methods to help the
customer and solve their problem as followings:
●
Service on line
●
Call for our customer service
Maintain or exchange
◆
Warranty Policy
According to the solving process, maintain, exchange or return should be
confirmed by our technical staff. You have to contact our sales person to solve
after this kind of negotiation.
1. We can one to one exchange the product in 3 month for the quality problem.
2. We guarantee to keep the product in good repair for 5 years.
◆
General problem
Normal problem
Problem reason
Problem solve
Power
indication
light off
Power socket not connect
Please
connect
power
socket
Link/Act indication
light off
1.RJ45 port line not connect Please connect cable
2.Not suitable cable
Please use this user manual
suitable cable
3.Ethernet equipment or
network card not work
Please solve equipment
these problem
FX and FX-Link/Act
indication light off
1.Fiber
optic
equipment
have problem
2.Fiber optic line cutoff or
connect error
3.Fiber optic signal loss too
much
Check if the remote Optical
output power and then
check the cause of problem.
TX and FX
indication light
working well, but
not transfer
Ethernet data
1.Optic cable and
equipment have not
correctly connect, then
leading to the optical output
powerless.
2.When the system just be
charged or network have
some
changes,
this
equipment and Ethernet
switch in network need self-
healing.
1.Connect well each fiber
optic connector
2. If our equipment and
Ethernet switch connect for
a long time but not transfer
data, please refresh the
system then charged again.